IEI Technology AUPS Series User Manual

Vesa mount intelligent ups module 12 v dc input or 9v- 36 v dc input network remote management support
Table of Contents

Advertisement

Quick Links

AUPS Series Power Module User Manual
Model:
AUPS Series
VESA Mount Intelligent UPS Module
12 V DC Input or 9 V–36 V DC Input
Network Remote Management Support
Rev. 2.00 – July 3, 2018
User Manual
Page i

Advertisement

Table of Contents
loading

Summary of Contents for IEI Technology AUPS Series

  • Page 1 AUPS Series Power Module User Manual Model: AUPS Series VESA Mount Intelligent UPS Module 12 V DC Input or 9 V–36 V DC Input Network Remote Management Support User Manual Page i Rev. 2.00 – July 3, 2018...
  • Page 2 AUPS Series Power Module User Manual Revision Date Version Changes July 3, 2018 2.00 Updated for R20 version: -Battery Specifications -Chapter 4: Software Application May 7, 2014 1.01 Added Appendix A: Safety Precautions November 12, 2008 1.00 Initial release Page ii...
  • Page 3 AUPS Series Power Module User Manual Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer.
  • Page 4 AUPS Series Power Module User Manual Manual Conventions WARNING Warnings appear where overlooked details may cause damage to the equipment or result in personal injury. Warnings should be taken seriously. CAUTION Cautionary messages should be heeded to help reduce the chance of losing data or damaging the product.
  • Page 5: Table Of Contents

    AUPS Series Power Module User Manual Table of Contents 1 INTRODUCTION ......................1 1.1 AUPS S ................... 2 ERIES VERVIEW 1.2 AUPS S UPS M ..............2 ERIES ODULE EATURES 1.3 E ....................3 XTERNAL VERVIEW 1.3.1 I/O interface panel (Standard) ................3 1.3.1.1 AUPS-A10 Power Input Connector ............
  • Page 6 AUPS Series Power Module User Manual 3.6 C AUPS S ................23 ONNECTING THE ERIES 4 SOFTWARE APPLICATION ..................24 4.1 I ......................25 NTRODUCTION 4.2 D ..................... 25 RIVER NSTALLATION 4.3 A ..................29 PPLICATION NSTALLATION 4.4 M DC P ............
  • Page 7 AUPS Series Power Module User Manual List of Figures Figure 1-1: AUPS Series UPS Module ..................2 Figure 1-2: AUPS Series Standard I/O Interface Connectors ............. 3 Figure 1-3: AUPS-A10 Power Input Connector ................4 Figure 1-4: AUPS-A20 Power Input Connectors ................4 Figure 1-5: AUPS-B10 Power Input Connector ................
  • Page 8 AUPS Series Power Module User Manual Figure 4-16: LAN Setting – Disable DHCP ................. 35 Figure 4-17: Application Setting ....................36 Figure 4-18: E-mail Setting ......................37 Figure 4-19: RJ-45 Remote LAN Connector ................38 Figure 4-20: Remote AP ....................... 39 Figure 4-21: Remote AP –...
  • Page 9 AUPS Series Power Module User Manual List of Tables Table 1-1: LED Indicators ......................6 Table 1-2: AUPS Series Specifications..................7 Table 1-3: AUPS-A10/AUPS-A20 Battery Specifications ............9 Table 1-4: AUPS-B10/AUPS-B20 Battery Specifications ............11 Table 2-1: Package List Contents ....................17...
  • Page 11: Introduction

    AUPS Series Power Module User Manual Chapter Introduction Page 1...
  • Page 12: Aups Series Overview

    IEI AFOLUX series panel PCs. The UPS module also receives either 12 V input or a wide range of inputs between 6 V and 36 V DC. The AUPS Series is built on an intelligent design and provides outstanding line and load regulations. The AUPS Series is capable of providing power for certain of time in power failure.
  • Page 13: External Overview

    AUPS Series Power Module User Manual 1.3 External Overview 1.3.1 I/O interface panel (Standard) The I/O interface panel of the AUPS Series (see Figure 1-2) has the following standard I/O interface connectors:  1 x 12 V DC output jack ...
  • Page 14: Aups-A10 Power Input Connector

    AUPS Series Power Module User Manual 1.3.1.1 AUPS-A10 Power Input Connector The AUPS-A10 has one power jack for +12 V DC input (Figure 1-3). Figure 1-3: AUPS-A10 Power Input Connector 1.3.1.2 AUPS-A20 Power Input Connectors The AUPS-A20 has one power jack and one terminal block for 9 V–36 V DC inputs (Figure 1-4).
  • Page 15: Aups-B10 Power Input Connector

    AUPS Series Power Module User Manual 1.3.1.3 AUPS-B10 Power Input Connector The AUPS-B10 has one 4-pin power connector for +12 V DC input (Figure 1-5). Figure 1-5: AUPS-B10 Power Input Connector 1.3.1.4 AUPS-B20 Power Input Connectors The AUPS-B20 has one 4-pin power connector and one terminal block for 9 V–36 V DC inputs (Figure 1-6).
  • Page 16: Led Indicators

    AUPS Series Power Module User Manual 1.3.2 LED Indicators The side panel of the AUPS Series has three LED indicators to indicate the power and battery status (Figure 1-7). Figure 1-7: AUPS Series LED Indicators All the LED statuses are listed in Table 1-1.
  • Page 17: Aups Series Specifications

    AUPS Series Power Module User Manual 1.4 AUPS Series Specifications The AUPS Series UPS module technical specifications are listed in Table 1-2. Model Name AUPS-A10 AUPS-A20 AUPS-B10 AUPS-B20 VESA Type VESA 75 mm x 75 mm VESA 75 mm x 75 mm...
  • Page 18: Battery Specifications

    AUPS Series Power Module User Manual 1.5 Battery Specifications The AUPS Series comes with a Li-ion smart battery. Some of the Li-ion battery specifications are listed in the following tables. 1.5.1 AUPS-A10/AUPS-A20 Battery Specifications Remarks AUPS Model AUPS-A10/AUPS-A20 Battery Pack...
  • Page 19: Table 1-3: Aups-A10/Aups-A20 Battery Specifications

    AUPS Series Power Module User Manual Max. Discharge Current 9.36 A Duration time < 5 sec. Pack Operating Temp. 0~40°C Max. Humidity: 85% RH 1 year: -20°C ~ +25°C Storage Temperature During storage, pack must be charged 3 months: -20°C ~ +45°C to 40%~50% every 3 months.
  • Page 20: Aups-B10/Aups-B20 Battery

    AUPS Series Power Module User Manual 1.5.2 AUPS-B10/AUPS-B20 Battery Specifications Remarks AUPS-B10/AUPS-B20 AUPS Model 8 cells 4S2P Battery Pack Li-ion Battery Type 0.5C charge/0.2C discharge at 25±3°C, Nominal Capacity 5200 mAh cut off voltage at 2.75 V/cell 0.5C charge/0.2C discharge at 25±3°C,...
  • Page 21: Table 1-4: Aups-B10/Aups-B20 Battery Specifications

    AUPS Series Power Module User Manual 1 year: -20°C ~ +25°C Storage Temperature During storage, pack must be charged 3 months: -20°C ~ +45°C to 40%~50% every 3 months. 1 month: -20°C ~ +65°C Protection Set: ≧4.24±0.02V / cell (0°C ~ 45°C), delay time: 2~4 sec.
  • Page 22: Aups Series Dimensions

    AUPS Series Power Module User Manual 1.6 AUPS Series Dimensions 1.6.1 AUPS-A10/AUPS-A20 Dimensions The AUPS-A10 and AUPS-A20 dimensions are shown in Figure 1-8. Figure 1-8: AUPS-A10/A20 Dimensions (mm) Page 12...
  • Page 23: Aups-B10/Aups-B20 Dimensions

    AUPS Series Power Module User Manual 1.6.2 AUPS-B10/AUPS-B20 Dimensions The AUPS-B10 and AUPS-B20 dimensions are shown in Figure 1-8. Figure 1-9: AUPS-B10/B20 Dimensions (mm) Page 13...
  • Page 24: Unpacking

    AUPS Series Power Module User Manual Chapter Unpacking Page 14...
  • Page 25: Anti-Static Precautions

    Electrostatic discharge (ESD) can cause serious damage to electronic components, including the AUPS Series. Dry climates are especially susceptible to ESD. It is therefore critical that whenever the AUPS Series, or any other electrical component is handled, the following anti-static precautions are strictly adhered to.
  • Page 26: Unpacking Checklist

    If some of the components listed in the checklist below are missing, please do not proceed with the installation. Contact the IEI reseller or vendor you purchased the AUPS Series from or contact an IEI sales representative directly. To contact an IEI sales representative, please send an email to sales@ieiworld.com.tw.
  • Page 27: Table 2-1: Package List Contents

    AUPS Series Power Module User Manual USB Type A to mini-B cable Screw kit Wall mount bracket Table 2-1: Package List Contents Page 17...
  • Page 28: Installation

    AUPS Series Power Module User Manual Chapter Installation Page 18...
  • Page 29: Anti-Static Precautions

    Electrostatic discharge (ESD) can cause serious damage to electronic components, including the AUPS Series. Dry climates are especially susceptible to ESD. It is therefore critical that whenever the AUPS Series is accessed internally, or any other electrical component is handled, the following anti-static precautions are strictly adhered to.
  • Page 30: Installation And Configuration Steps

    The battery pack must be installed to enable the UPS module. To install the battery pack, follow the steps below. Step 1: Remove the four top cover retention screws (Figure 3-1 and Figure 3-2) and lift the top cover off the AUPS Series module. Figure 3-1: Top Cover Retention Screws (Rear Panel) Page 20...
  • Page 31: Mounting The Aups Series

    Replace the top cover. Step 0: 3.5 Mounting the AUPS Series To mount the AUPS Series onto the rear panel of the AFOLUX panel PC, follow the steps below. Step 1: Install the mounting bracket onto the rear panel of the AFL panel PC. Align...
  • Page 32: Figure 3-4: Mounting Bracket Installation

    (Figure 3-4). Figure 3-4: Mounting Bracket Installation Step 2: Place the AUPS Series onto the mounting bracket. Secure the AUPS Series to the bracket with three retention screws, one on the top panel and one on each side panel (Figure 3-5).
  • Page 33: Connecting The Aups Series

    AUPS Series Power Module User Manual 3.6 Connecting the AUPS Series To support the UPS function to the panel PC, the AUPS Series must be connected to the power source and to the panel PC. Figure 3-6 shows the connections.
  • Page 34: Software Application

    AUPS Series Power Module User Manual Chapter Software Application Page 24...
  • Page 35: Introduction

    AUPS Series Power Module User Manual 4.1 Introduction The IEI AUPS application detects the information of the smart battery and monitors the battery status. It is recommended to execute this AUPS application in Windows 7 or above. 4.2 Driver Installation Follow the steps below to install the necessary drivers.
  • Page 36: Figure 4-2: Driver Welcome Screen

    AUPS Series Power Module User Manual Step 3: A welcome screen appears (Figure 4-2). To continue the installation process click Next. Figure 4-2: Driver Welcome Screen Step 4: The license agreement in Figure 4-3 appears. Read the License Agreement. Check I accept the terms of license agreement and click Next to continue.
  • Page 37: Figure 4-4: Choose Destination Location

    AUPS Series Power Module User Manual Step 5: The Choose Destination Location window appears (Figure 4-4). Select a folder to install the driver. Figure 4-4: Choose Destination Location Step 6: Click Next and the InstallShield Wizard is ready to install the driver (Figure 4-5).
  • Page 38: Figure 4-6: Installshield Wizard Complete Screen

    AUPS Series Power Module User Manual Step 8: The InstallShield Wizard Complete window appears (Figure 4-6). Check Launch the CP210x VCP Driver Installer and click Finish to launch the CP210x USB to UART Bridge Driver Installer. Figure 4-6: InstallShield Wizard Complete Screen...
  • Page 39: Application Installation

    AUPS Series Power Module User Manual 4.3 Application Installation Follow the steps below to install the AUPS application. Step 1: Download the AUPS setup file from IEI website. Run the AUPS_SetupV100A.exe file. Step 2: A welcome screen appears (Figure 4-9). To continue the installation process click Install.
  • Page 40: Figure 4-10: Installation Complete

    AUPS Series Power Module User Manual Figure 4-10: Installation Complete Step 5: To launch the application, double click the shortcut (Figure 4-11) on the desktop. Figure 4-11: IEI AUPS Application Overview Page 30...
  • Page 41: Monitoring Dc Power And Smart Battery

    (Figure 4-12). The following sections describe the status information in details. Figure 4-12: Status Information 4.4.1.1 DC Power Status When the DC power is connected to the AUPS series power module, the AUPS application detects it and shows in the screen as Figure 4-13. Figure 4-13: DC Detection...
  • Page 42: Battery Status

    AUPS Series Power Module User Manual 4.4.1.2 Battery Status The AUPS application detects the smart battery installed in the AUPS series power module and shows the battery status in the screen. Capacity Current battery capacity. Using The battery is being used.
  • Page 43: Battery Information

    AUPS Series Power Module User Manual 4.4.2 Battery Information Click on the BATTERY tab to view the information of battery. The total battery time is shown in the top of the battery screen to indicate the total battery remaining time (this information will not be displayed when the battery is being charged).
  • Page 44: Lan Setting

    AUPS Series Power Module User Manual 4.4.3 LAN Setting The LAN page is where to configure the Remote LAN settings for power on/off remote control and battery monitoring. To save the modified Host Name, click the SET button. Figure 4-15: LAN Setting...
  • Page 45: Using Static Ip

    AUPS Series Power Module User Manual 4.4.3.1 Using Static IP DHCP is enabled by default in the application. To use static IP, disable the DHCP option and fill in the network information. To save the modified parameters of this page, click the button.
  • Page 46: Setting

    Shut down condition Set the battery capacity parameter for the system to shut (capacity %) down automatically. DC off delay time Set the delay time for the AUPS series to power off after the (0~65536 sec) system shut down. Page 36...
  • Page 47: E-Mail

    AUPS Series Power Module User Manual System will be Set the battery capacity parameter for the system to down-converted automatically switch to the Balanced power plan set in its (capacity %) Windows OS. System go to sleep mode Set the battery capacity parameter for the system to go into (capacity %) sleep mode automatically.
  • Page 48: Remote Control And Monitoring

    4.5 Remote Control and Monitoring The AUPS Series can be controlled (power on/off) and monitored through a remote computer located in the same subnet with the AUPS Series. To control and monitor the AUPS Series remotely, follow the steps below.
  • Page 49: Figure 4-20: Remote Ap

    AUPS Series Power Module User Manual Figure 4-20: Remote AP Step 4: To access the web interface for advanced monitoring and functions, double click the IP address of the connected AUPS Series. Figure 4-21: Remote AP – IP Address Page 39...
  • Page 50: Figure 4-22: Remote Management Web Interface - Status

    AUPS Series Power Module User Manual Step 5: The following page shows in a web browser. Figure 4-22: Remote Management Web Interface - Status Step 6: To send an email to an administrator through the SMTP server, click Send E-mail button on the left. Fill out the information as indicated in Figure 4-23.
  • Page 51: Figure 4-24: Enter User Name And Password

    AUPS Series Power Module User Manual Step 7: To configure the AUPS Series network setting, click the Configuration button on the left. Step 8: A window prompts for the user name and password. The default user name and password for the LAN setting page are: ...
  • Page 52: Figure 4-25: Remote Management Web Interface - Configuration

    AUPS Series Power Module User Manual Figure 4-25: Remote Management Web Interface - Configuration Page 42...
  • Page 53: A Safety Precautions

    AUPS Series Power Module User Manual Appendix Safety Precautions Page 43...
  • Page 54 AUPS Series Power Module User Manual DANGER! 1. Disassemble and Reconstruction “Do not disassemble or reconstruct battery” The battery pack has safety function and protection circuit to avoid the danger. If they have serious damage, it will cause the generating heat, smoke, rupture or flame.
  • Page 55 AUPS Series Power Module User Manual are cases that it will be overcharged or the abnormal chemical reaction will occur in cells. It caused the generating heat, smoke, rupture or flame. 8. Penetration “Do not drive a nail into the battery, strike it by hammer, or tread it”...
  • Page 56 AUPS Series Power Module User Manual 15. Inappropriate Use for Other Equipment “Do not use battery for other equipment” If the battery is used for unspecified equipment, it will deteriorate its performance and cycle-life. At worst, abnormal current will flow or battery may generate heat, smoke, rupture or flame.
  • Page 57 AUPS Series Power Module User Manual 6. Rust, Changing Color and Deformation “Do not use an abnormal battery” In case the battery has bad smell or is generated its changing color or deformation or causes something wrong in using (includes charging and storage), let it take out from equipment or charger and do not use it.
  • Page 58 AUPS Series Power Module User Manual 8. Keep Battery Away From Children Keep the battery out of the reach of younger children. And also, pay attention when the battery is taken out from the charger or equipment by little children.
  • Page 59: B Hazardous Materials Disclosure

    AUPS Series Power Module User Manual Appendix Hazardous Materials Disclosure Page 49...
  • Page 60 AUPS Series Power Module User Manual The details provided in this appendix are to ensure that the product is compliant with the Peoples Republic of China (China) RoHS standards. The table below acknowledges the presences of small quantities of certain materials in the product, and is applicable to China RoHS only.
  • Page 61 AUPS Series Power Module User Manual 此附件旨在确保本产品符合中国 RoHS 标准。以下表格标示此产品中某有毒物质的含量符 合中国 RoHS 标准规定的限量要求。 本产品上会附有”环境友好使用期限”的标签,此期限是估算这些物质”不会有泄漏或突变”的 年限。本产品可能包含有较短的环境友好使用期限的可替换元件,像是电池或灯管,这些元 件将会单独标示出来。 部件名称 有毒有害物质或元素 铅 汞 镉 六价铬 多溴联苯 多溴二苯 醚 (Pb) (Hg) (Cd) (CR(VI)) (PBB) (PBDE) 壳体 显示 印刷电路板 金属螺帽 电缆组装 风扇组装 电力供应组装 电池 O: 表示该有毒有害物质在该部件所有物质材料中的含量均在 SJ/T 11363-2006 (现由 GB/T 26572-2011 取代) 标准规定的限量要求以下。...