Goldacres ZETA Series Operator And Parts Manual

Goldacres ZETA Series Operator And Parts Manual

Udor diaphragm pumps

Advertisement

UDOR Diaphragm
Pumps
Operator's & Parts Manual
GA8700374 REV 1 .0 MAR 16
1

Advertisement

Table of Contents
loading

Summary of Contents for Goldacres ZETA Series

  • Page 1 UDOR Diaphragm Pumps Operator’s & Parts Manual GA8700374 REV 1 .0 MAR 16...
  • Page 2: Table Of Contents

    IOTA 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Goldacres Warranty Statement . . . . . . . . .37 Kappa 40 / Delta 40 .
  • Page 3: General Information And Specs

    A quality multigrade engine oil should be used maintenance than diaphragm pumps. At in the pump. Goldacres we have not found this to be the Pump Identification case. Cast iron pumps are subject to chemical erosion. Centrifugal pumps which are run...
  • Page 4: Before Start Up

    Safety Symbols content, such as seawater for example. - In workplaces where there is a corrosive The “WARNING” symbol here at the side or explosive atmosphere. draws the operator’s attention to situations and/or problems related to the correct - In the presence of any liquid that is operation of the Pump.
  • Page 5: Controls On System

    Department of UDOR. The rotation direction of the shaft of UDOR Pumps may be clockwise or anticlockwise. Inlet And Outlet Of The Pump Controls on System The Inlet of the liquid to be pumped, also called intake or supply, is generally of larger Unloader Valve diameter than the Outlet, also called delivery.
  • Page 6: Installation, Start Up And Switching Off

    Assembly accumulator may cause system malfunctioning, damage the accumulator Fit the Pump on a rigid surface keeping the diaphragm or the whole Pump. power take-off and support feet horizontal to The accumulator’s air pressure varies ensure correct drainage in the case of leakage according to the Pump’s operating pressure: of water or oil.
  • Page 7: Maintenance

    example through the seal rings of the 1. DRAIN CRANKCASE OIL: Drain Pump crankshaft. crankcase by removing the oil drain plug (T) located at the bottom of the Pump, also Do not throw the liquid used to wash remove the oil fill cap (F) or plug (R). the Pump outdoors but observe current standards.
  • Page 8: Lubrication

    Do Not Start The Pump If There Is No 8. REFILL PUMP CRANKCASE: Re-mount Oil In The Pump! the oil drain plug (T). Fill Pump with SAE 15W-40 OIL to recommended mark on the oil During maintenance, you are reservoir (H) or on the sight glass (S). Rotate recommended to: the crankshaft (N) while filling to eliminate air - Use and wear suitable personal...
  • Page 9: Trouble Shooting

    Trouble Shooting Problems Probable Causes Solutions No pressure. Insufficient strainer capacity, Use larger capacity strainer or or dirty or plugged strainer. clean strainer. Very little pressure. Suction hose restriction. Eliminate restriction. Pressure drops below Collapsed suction hose inside Replace collapsed hose. working range when relief or outside tank restricting valve is open to boom or...
  • Page 10: Oil And Weight

    Oil and Weight Series Recommended Oil Quantity Pump Weight Kg . Lbs . Lt . Gal . Kg . Lbs . ZETA 70 0,5. 1.10 0,56 0.15 ZETA 85 1,02 2.25 1,14 0.30 ZETA 100 1,02 2.25 1,14 0.30 ZETA 120 1,04 2.29 1,16...
  • Page 11: Torque Specification

    Torque Specification PTO for details on Torque Specification...
  • Page 12 Torque Specification Diaphragm Bolt Head Bolts Pulsation Inlet Flange Bolts (use Loctite 243) Dampener Bolts ® MOD . N•m lbf•ft N•m lbf•ft N•m lbf•ft N•m lbf•ft ZETA 70 ZETA 85 ZETA 100 ZETA 120 ZETA 140 ZETA 170 ZETA 200 ZETA 230 ZETA 260 ZETA 300...
  • Page 13 Bearing Flange Oil Cup Bolts Manifold Bolts Manifold Bolts Bolts (Aluminium/Brass) (Plastic) MOD . N•m lbf•ft N•m lbf•ft N•m lbf•ft N•m lbf•ft ZETA 70 ZETA 85 ZETA 100 ZETA 120 ZETA 140 ZETA 170 ZETA 200 ZETA 230 ZETA 260 ZETA 300 RO 320 RO 400...
  • Page 14: Pump

    Pump is to be left in a cold environment. The water may freeze and cause damage to pump if pumping is attempted while water is frozen. The pump is critical to the sprayers Empty pump of all water (run the pump dry for performance.
  • Page 15: To Replace A Side Diaphragm In Pump

    Air Damper Chamber A change in oil colour indicates a pump problem. The oil should be regularly monitored when spraying so that any problem is detected as soon as possible. If the oil goes REMOVE AIR FROM AIR DAMPER milky in colour, it is likely the diaphragm has CHAMBER BEFORE REMOVING been damaged and the spray mixture has AIR DAMPER CHAMBER COVER...
  • Page 16: Iota 20

    IOTA 20...
  • Page 17 serieseries IOTA pompe a membrana bassa pressione low pressure diaphragm pumps IOTA 20 max. 19 l/min - 5.0 GPM • 20 bar - 290 PSI • 600 RPM IOTA 25 GR max. 24 l/min - 6.3 GPM • 20 bar - 290 PSI • 600 RPM alberi P.
  • Page 18: Kappa 40 / Delta 40

    Kappa 40 / Delta 40...
  • Page 19: Goldacres

    serieseries DELTA pompe a membrana alta pressione high pressure diaphragm pumps DELTA 40 max. 48 l/min - 12.7 GPM • 40 bar - 580 PSI • 550 RPM DELTA 50 max. 53 l/min - 14 GPM • 40 bar - 580 PSI • 550 RPM alberi P.
  • Page 20: Zeta 70

    Zeta 70...
  • Page 21: Goldacres

    serieseries ZETA pompe a membrana bassa pressione low pressure diaphragm pumps ZETA 70 max. 70.5 l/min - 18.6 GPM • 20 bar - 290 PSI • 550 RPM alberi P. di F. disponibili available P.T.O. shaft TS 1C Per le dimensioni degli Alberi P.
  • Page 22: Zeta 85

    Zeta 85...
  • Page 23: Goldacres

    serieseries ZETA pompe a membrana bassa pressione low pressure diaphragm pumps ZETA-P 40 max. 44 l/min - 11.6 GPM • 20 bar - 290 PSI • 550 RPM ZETA-P 85 max. 85 l/min - 22.5 GPM • 20 bar - 290 PSI • 550 RPM ZETA-P 100 max.
  • Page 24: Zeta 100

    Zeta 100...
  • Page 25: Goldacres

    serieseries ZETA pompe a membrana bassa pressione low pressure diaphragm pumps ZETA 100 max. 98 l/min - 25.9 GPM • 20 bar - 290 PSI • 550 RPM alberi P. di F. disponibili available P.T.O. shaft TS 1C Per le dimensioni degli Alberi P.
  • Page 26: Zeta 140

    Zeta 140...
  • Page 27: Goldacres

    serieseries ZETA pompe a membrana bassa pressione low pressure diaphragm pumps ZETA 120 max. 116 l/min - 31 GPM • 20 bar - 290 PSI • 550 RPM ZETA 140 max. 135 l/min - 36 GPM • 20 bar - 290 PSI • 550 RPM alberi P.
  • Page 28: Zeta 170

    Zeta 170...
  • Page 29 serieseries ZETA pompe a membrana bassa pressione low pressure diaphragm pumps ZETA 170 max. 170 l/min - 45 GPM • 20 bar - 290 PSI • 550 RPM PSI • 550 RPM PSI • 550 RPM ZETA 200 max. 198 l/min - 52 GPM • 20 bar - 290 PSI • 550 RPM PSI •...
  • Page 30: Zeta 260

    Zeta 260...
  • Page 31 serieseries ZETA pompe a membrana bassa pressione low pressure diaphragm pumps ZETA 230 max. 228 l/min - 60 GPM • 20 bar - 290 PSI • 550 RPM ZETA 260 max. 256 l/min - 68 GPM • 20 bar - 290 PSI • 550 RPM ZETA 300 max.
  • Page 32: Zeta 300

    Zeta 300...
  • Page 33: Pump Kits

    UDOR Diaphragm Pump Spare Part Kits Diaphragm kits consist of side diaphragms and air diaphragm where applicable. Suits Pump Type Part No . Kappa 40 Diaphragm kit GA5023870-SK Zeta 85 Diaphragm kit KIT-ZETA85D Zeta 100 Diaphragm kit KIT-ZETA100D RO121/130 Diaphragm kit KIT-ZETA140D Zeta 140 Diaphragm kit...
  • Page 34: Zeta Pump Kit Contents

    Zeta pump kit contents GA Number Contents KIT-ZETA140-C Zeta 140 Complete Kit 3 x 090359 1 x 090314 6 x 600677 6 x GA5020060 1 x 000761 1 x 110158 1 x 110179 Zeta 140 Diaphragm Kit KIT-ZETA140-D 3 x 090359 1 x 090314 KIT-ZETA170-C Zeta 170 Complete Kit...
  • Page 35: Safety

    The following pages outline important safety all times. information. At Goldacres safety is a high • Water weighs 1kg per litre, however priority. These safety and warning instructions...
  • Page 36: Personal Protective Equipment (Ppe)

    2. If you continue to experience problems the appropriate PPE to use with the chemicals then please contact Goldacres on 03 5342 you are using. 6399. The operator will advise the method Airborne Particles of warranty service for your product.
  • Page 37: Goldacres Warranty Statement

    Goldacres brand products will not be covered by Goldacres warrants its authorized Dealers who in Goldacres Warranty. Only labour and parts directly attributable to the repair of the Goldacres unit is turn warrants the original purchaser (Owner) that covered. each new Goldacres Product will be free from proven defect in materials and workmanship for twelve (12) •...
  • Page 38: Terms And Conditions

    The warranties provided under these terms and conditions do not extend to second hand from the use of the Goods. Goldacres shall be under no liability for damages arising out of or used Goods that may be sold by Goldacres.
  • Page 39: Goldacres

    Goods (section 130); for Goldacres by way of bona fide sale at full market value and in the ordinary course of its to receive a statement of account following disposal of Goods (section 132(2));...
  • Page 40: Goldacres

    1-3 Morang Crescent, Mitchell Park Vic 3355 P: 03 5342 6399 F: 03 5342 6308 info@goldacres.com.au goldacres.com.au...

Table of Contents