SIMPLESEAL
DOWNLIGHTS
™
CDL6VL2 LED SERIES
INSTALLATION INSTRUCTIONS
GENERAL
This instruction sheet applies for the CDL6VL2, HADL6VL2, MDL6VL2, M2DL6VL2, and TDL6VL2 Downlight.
• D isconnect power to all circuits before wiring system.
• I nstall in accordance with all national, state, and local codes.
• B e sure to connect LED luminaire's chassis GROUND connection to a GROUNDED conductor wire.
• R ead all product markings and labels to ensure correct installation of a system. Supplemental instructions may
be located on the fixture, in addition to this instruction sheet, regarding orientation or mounting restrictions.
This lighting system contains sensitive electronics. Take care to avoid damage by improper handling or static
electricity discharge (ESD). Either type of damage could render the system inoperable or cause latent failure.
I. Luminaire Mounting Procedure GRID FIXTURE
• C ut an 8.125" diameter hole in ceiling
panel and install panel.
• I nsert conduit or c-channel (by others) through
mounting brackets. Bend brackets to secure.
Lift fixture into ceiling through adjacent opening
and position over cutout.
www. kenall.com
P: 800-4-Kenall
INSTALLATION INSTRUCTIONS
IMPORTANT SAFEGUARDS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
When using electrical equipment, basic safety precautions
should always be followed, including the following:
should always be followed, including the following:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH
THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS
THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS
BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH
BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH
ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT
ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT
TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS
TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS
AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE.
AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE.
SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE
SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE
FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING
FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING
ORIENTATION, OR MOUNTING RESTRICTIONS.
ORIENTATION, OR MOUNTING RESTRICTIONS.
SAVE THESE INSTRUCTIONS
SAVE THESE INSTRUCTIONS
F: 847-360-1781
1020 Lakeside Drive Gurnee, Illinois 60031
Figure 1
CDL6VL2_F-5507_110514
1
Need help?
Do you have a question about the SIMPLESEAL CDL6VL2 LED SERIES and is the answer not in the manual?
Questions and answers