The 9101 VERI FY paper tape function operates normally. The 9101 DUPLICATE paper tape function
proceeds normally but data is collected in RAM buffer instead of programming. If the LAST ADDRESS is
included in the address field, control is transferred to the PM9005 personality module. The operation
proceeds as defined for manual operation. Control is not regained by the paper tape.
If the LAST ADDRESS condition does not occur the data remains in the RAM buffer and programming
does not occur.
Operation With 9102 Teletype Option
The LIST and VERIFY teletype-functions operate normally.
The PROGRAM and DUPLICATE teletype functions proceed normally but data is collected in the RAM
buffer. If the LAST ADDRESS condition occurs, control is transferred to the PM9005 personality module.
The programming operation proceeds as defined for the manual operation. Control is not regained by the
teletype. If programming errors occur the error information appears in the Hex display as in the keyboard
operation.
If the LAST ADDRESS condition does not occur the data remains in the RAM and programming does not
occur.
Operation With 9104 Parallel Interface Option
The 9104 LIST mode operates normally with the PM9005.
The 9104 PROGRAM mode proceeds normally but data is collected in the RAM instead of programming. If
the LAST ADDRESS is included in the address field, control is transferred to the PM9005 personality
module when the last address data transfer occurs. The RESPONSE for the last data transfer will be
delayed until the mUlti-pass programming is complete as defined below.
The programming operation proceeds as in the manual operation. When the programming and read-check
operations are complete, control returns to the 9104 remote option. Sucessful programming is indicated
by a normal RESPONSE signal. Unsuccessful programming is indicated by the RESPONSE-ERROR
signal combination. If programming is unsuccessful it is necessary to LIST and compare to determine
Which locations failed to program.
If the LAST ADDRESS condition does not occur the data remains in the RAM buffer and programming
does not occur.
Operation With 9105 RS232 Option
The 9105 LIST mode operates normally with the PM9005.
The 9105 PROGRAM mode proceeds normally but data is collected in the RAM instead of programming. If
the LAST ADDRESS is included in the address field, control automatically transfers to the PM9005
personality module when the last address data transfer occurs. The acknowledgement for the last data
transfer will be delayed until the multi-pass programming is complete as defined below.
The programming operation poceeds as in the manual operation. When the programming and read-check
operations are complete, control returns to the 9105 remote option. Successful programming is indicated
by a normal ACK control character. Unsuccessful programming is indicated by the NAK control
character. If programming is unsuccessful it is necessary to LIST and compare to determine which
locations fai led to program.
If the LAST ADDRESS condition does not occur the data remains in the RAM buffer and programming
does not occur.