  • Page 1 Air quality detector Instruction of AQ9600 www.perfect-prime.com cs@perfect-prime.com Please register product warranty on our website...
  • Page 2: Table Of Contents

    Table of Content Product overview II. Considerations III. Product description IV. Function setting operation V. Measurement VI. New air quality level VII. Charging VIII. Product specification...
  • Page 3: Product Overview

    I. Product overview AQ9600 has the function of measuring PM2.5, PM10, counting of dust particles, temperature and humidity. The product is provided with high measurement precision, stable performance and simple operation and convenient to carry. It is suitable for indoor environment of family, office, inside of cars and natural environment, etc.
  • Page 4 2. LCD display description Number Display description Hour/minute/second Year/month/day Battery level indication Counting unit Schematic diagram of concentration grade Display area of particle counting Humidity Temperature Measuring object Weight unit Display area of particle weight calculation 3. Key function description...
  • Page 5 Key name and brief function number Power key [ ]: press to power on/off. Operating measurement key [RUN] At the main interface, press to start data sampling. During the sampling period of 50s, other keys are disabled and cannot operate. Only power key can function. Enter key [ENTER] At the mode of historical record, press--confirm the page number of the selected pages.
  • Page 6: Function Setting Operation

    IV. Function setting operation Function Function Function setting operation type items Check historical record: at the main interface, press [▼] key to enter historical record mode; press [ ] key and ENTER Page the current page is selected. At the moment, press [▲] key number: or [▼] key to go through the data.
  • Page 7: Measurement

    V. Measurement The instrument should be placed in an open space before measurement to avoid blocking of the sensors. Press the power key to switch on. Press [RUN] key at the main interface and the instrument will enter the sampling state of 50 seconds. At the moment, do not operate the instrument first.
  • Page 8: Product Specification

    VIII. Product specification Principle of PM2.5 Sensors Optoelectronic type Sampling method Pumping type Light sources Laser diode Grain size channels 0. 3um 2.5um 10 um Flowrate 1L/min Measurement range 0-1000ug/m3 Resolution ratio 1 ug Test method Manual Sampling time Sampling method Pumping type Typical precision <20%...