Trilite SG10-12RG Installation Instructions

Stop-go loading dock safety light

Advertisement

Available languages

Available languages

IMPORTANT SAFETY INFORMATION

CAUTION! The individual user should determine prior to use whether this device is suitable, adequate,
or safe for the use intended. Since individual applications are subject to great variation, the manufacturer
makes no representation or warranty as to the fit or suitability of these devices for any specific application.
CAUTION! Ensure that the power supply matches the voltage rating of the light.
CAUTION! Units with incandescent lamps require a flashing power supply or integrated flasher device to
avoid heat damage to the lens. LED units can operate safely when not flashing.
CAUTION! 12 volt units with LED lamps require careful control of the DC input voltages if generated from
AC power sources. Ensure that voltage does not exceed 110% of rated voltage.
INSTALLATION INSTRUCTIONS
These models are intended for use with external peripheral controls and circuitry provided by the user.
1. Choose a location within convenient distance to a suitable power source. The power connection can be
through the underside of the housing or through the back plate. Use the ½" EMT fitting provided.
2. Using the housing as a template, mark and drill four (4) corner holes in an appropriate mounting location.
If mounting to brick or masonry, size the holes to accept ¼" diameter lag-type fasteners and anchors.
3. Use the back plate gasket provided when mounting unit to the wall.
4. Connect the control/supply wires to an appropriate external switching device.
See wiring diagram for reference.

REPLACEMENT PARTS LIST

Part#
Descriptions
A1612R
Red signal assembly, 12 VDC
A1612G
Green signal assembly, 12 VDC
A1624RH
Red signal assembly, 24 VAC/VDC
A1624GH
Green signal assembly, 24 VAC/VDC
A16115R
Red signal assembly, 120 VAC
A16115G
Green signal assembly, 120 VAC

LIMITED WARRANTY

This Tri Lite product may incorporate an LED bulb, warranted to be free from defects in materials and/or workmanship for (3) three years from the date of delivery to
Purchaser. The Limited Warranty does not apply to severe applications.
All other components within this unit are under warranty for (1) year. If any component parts do not conform exactly to the specifications and physical dimensions referred
to above, and the Purchaser, at its expense, returns the product or component parts to the Seller together with a report of defects, the Seller shall review the inspection
report and inspect the items and shall authorize, at its option, either the repair or replacement of any non-conforming products or component parts. Upon expiration of
the warranty period, all liability of the Seller shall be terminated.
Seller shall not be liable for any injury, loss or damage, direct or consequential arising out of the use or the ability to use the product. This warranty gives specific legal
rights. You may have other rights, which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, so that the
above limitation of exclusion may not apply to you.
info@triliteinc.com | t: 1-773-384-7765 | f: 1-773-384-5115 | www.triliteinc.com | Designers and manufacturers of specialty electrical products. Since 1922.
INSTALLATION INSTRUCTIONS for MODELS
SG10-RG (Incandescent) and SG10-RG-LED
SG10 CONFIGURATIONS
Part#
SG10-12RG
SG10-12RG-LED
SG10-24RG
SG10-24RG-LED
SG10-115RG
SG10-115RG-LED
Voltage
Amps
Bulb Type
12v
2.17
Incandescent
12 VDC
0.30
LED
24v
1.10
Incandescent
24v
0.11
LED
120v
0.21
Incandescent
120v
0.03
LED
953063 | REV B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG10-12RG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Trilite SG10-12RG

  • Page 1 See wiring diagram for reference. REPLACEMENT PARTS LIST SG10 CONFIGURATIONS Part# Descriptions Part# Voltage Amps Bulb Type A1612R Red signal assembly, 12 VDC SG10-12RG 2.17 Incandescent A1612G Green signal assembly, 12 VDC SG10-12RG-LED 12 VDC 0.30 A1624RH Red signal assembly, 24 VAC/VDC SG10-24RG 1.10...
  • Page 2 CONFIGURATIONS DU SG10 Nº de pièce Descriptions Nº de pièce Tension Ampères Type d’ampoule A1612R Ensemble pour clignotant rouge, 12 VCC SG10-12RG 2,17 Incandescente A1612G Ensemble pour clignotant vert, 12 VCC SG10-12RG-LED 12 VCC 0,30 A1624RH Ensemble pour clignotant rouge, 24 VCA/VCC...
  • Page 3 WIRING DIAGRAM for MODELS SG10-RG (Incandescent) and SG10-RG-LED SG10-12RG VDC UNIT SG10-115RG VAC UNIT SG10-24RG VAC/VDC UNIT This wire used on Incandescent 120 VAC units only BLACK RED (+) CHASSIS GROUND GREEN BLACK (-) WHITE (NEUTRAL) GREEN GREEN Internal Connection...
  • Page 4 SCHÈMA DE CONNEXION pour les MODÈLES SG10-RG (Incandescente) et SG10-RG-LED (DEL) SG10-12RG VCC UNITÉS Ce fil est utilisé uniquement SG10-24RG VCA/VCC UNITÉS SG10-115RG VCA UNITÉS sur les unités incandescentes de 120 VCA NOIR ROUGE (+) ROUGE ROUGE MASSE DU CHÂSSIS...

This manual is also suitable for:

Sg10-12rg-ledSg10-24rgSg10-24rg-ledSg10-115rgSg10-115rg-led

Table of Contents