  • Page 1 USER MANUAL BM INTELLIGENT LCD UPS BM1500AVRLCD| BM1350AVRLCD BM1000AVRLCD | BM850AVRLCD www.bxterra.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS WARRANTY & REGISTRATION......SAFETY INSTRUCTIONS........INSTALLATION & OPERATION......PRODUCT OVERVIEW........BATTERY REPLACEMENT........BATTERY REPLACEMENT PROCEDURE..... LCD DISPLAY............FAULT CODES............. TROUBLESHOOTING.......... TECHNICAL SPECIFICATIONS......9-10 CERTIFICATIONS..........WARRANTY INFORMATION......TECHNICAL SUPPORT........CONSIGNES DE SÉCURITÉ........13 - 14 REMPLACEMENT DE LA BATTERIE....INFORMATIONS DE GARANTIE......
  • Page 3: Safety Instructions

    WARRANTY & REGISTRATION This bXterra product is constructed to provide unmatched power protection, quality and performance for the duration of its lifetime. Please take a few minutes to register your product at www.bXterra.com/registration. Registration certifies your product’s warranty, confirms your ownership in the event of a product loss or theft and entitles you to free technical support.
  • Page 4: Installation & Operation

    There are no user-serviceable parts inside the UPS except for the battery. INSTALLATION & OPERATION INTRODUCTION not always be safe for your devices. The Thank for choosing a bXterra BM850AVRLCD/BM1000AVRLCD feature Uninterruptible Power Supply. This UPS 1,080 Joules and the BM1350/1500AVRLCD system is Energy Star certified and feature 1,500 Joules of surge protection.
  • Page 5 These outlets provide battery backup, Download the latest version of EMI filtering, line conditioning, and surge PowerFrame software from protection. Battery power is automatically www.bxterra.com to your hard drive. provided in case of power failure. Follow on-screen instructions to complete the software installation.
  • Page 6: Product Overview

    DEVICE STORAGE To store the UPS for an extended period, cover the unit and fully charge the battery before disconnecting from AC power. While in storage, recharge the battery every three months to prolong optimal battery life. in storage, PRODUCT OVERVIEW 1.
  • Page 7: Battery Replacement

    Replace with a battery that matches the specifications of the original battery. REMINDER: Batteries are considered hazardous waste and must be disposed of properly. bXterra asks to Recharge the UPS for 8-16 hours to fully please find a local retailer or hazardous waste disposal charge the battery.
  • Page 8: Lcd Display

    LCD DISPLAY MODE DISPLAY DESCRIPTION MODE DISPLAY DESCRIPTION Turning on the When the UPS starts Battery Mode Alarm will beep every up, all icons will 10 seconds and LCD illuminate for information will be 3 seconds. displayed in the following order when pressing button.
  • Page 9: Fault Codes

    Wait 10 projecting from the back of the from an overload seconds, reset the circuit breaker unit then turn the UPS on again. If any abnormal situations occur that are not listed above, please contact bXterra support for help.
  • Page 10: Technical Specifications

    TECHNICAL SPECIFICATIONS MODEL BM1500AVRLCD BM1350AVRLCD BM1000AVRLCD BM850AVRLCD Line Interactive Topology INPUT Voltage 120V Frequency Range 50/60 Hz ± 5 Hz (auto-sensing) Input Voltage Range 86 - 140 V Plug Type NEMA 5-15P Right Angle, 45° Offset Plug Style 6 ft...
  • Page 11 MODEL BM1500AVRLCD BM1350AVRLCD BM1000AVRLCD BM850AVRLCD MANAGEMENT & COMMUNICATIONS Multifunction LCD Panel Input/Output Voltage, Input/Output Frequency, Load Level, Battery Capacity, Estimated Remaining Runtime, Site Wiring Fault, Other Device Faults, Mute HID Compliant USB Port Management Cable USB Cable Audible Alarms On Battery, Low Battery, Overload, Fault...
  • Page 12: Certifications

    Limited Warranty available on our website, repair or replace that product. bXterra will act on its own discretion as the sole remedy for bXterra’s breach of its Limited Warranty. Full details of this Limited Warranty and bXterra’s Directly Connected Equipment Guarantee can be found on our website at www.bxterra.com/warranty or...
  • Page 13: Technical Support

    Technical Support Contact bXterra technical support for installation support, troubleshooting or general questions by emailing us at support@bxterra.com or visit our website at bxterra.com.
  • Page 14: Consignes De Sécurité

    à l’intérieur de équipements de survie, des fours à micro- l’onduleur, à l’exception de la batterie. ondes ou des aspirateurs à l’UPS. bXterra • N’ouvrez pas l’onduleur sauf pour effectuer le ne vend pas d’équipements destinés à des remplacement de la batterie.
  • Page 15: Remplacement De La Batterie

    INFORMATIONS DE GARANTIE Votre produit bXterra est assorti d’une garantie limitée de 3 ans. bXterra garantit que ce produit, s’il est utilisé de manière appropriée et conformément à toutes les instructions applicables, contre les défauts de matériaux et de fabrication du produit pendant 3 ans à compter de la date d’achat. S’il est prouvé...