GLP Force 120 Operating Instructions Manual

Speed, variable direction fan unit with internal rgb led lighting

Advertisement

Quick Links

Operating Instructions
Force 120
Version: 1.1 (2018-03-02) - en-us
Support@germanlightproducts.com
www.germanlightproducts.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Force 120 and is the answer not in the manual?

Questions and answers

Summary of Contents for GLP Force 120

  • Page 1 Operating Instructions Force 120 Version: 1.1 (2018-03-02) - en-us Support@germanlightproducts.com www.germanlightproducts.com...
  • Page 2: Table Of Contents

    DMX start address and setup..................9 7.2.2 Settings........................10 7.2.3 Information........................11 7.2.4 Manual control......................12 7.2.5 Test..........................12 7.2.6 Service......................... 12 Switch off device.......................... 13 Cleaning and maintenance........................14 Technical data.............................15 10 Recycling/disposal/environmental protection................... 16 11 Contact................................ 17 page 2/20 Operating Instructions Force 120 2018-03-02...
  • Page 3: Representation Conventions

    One or more bolded words indicate a term that can be found exactly the same on the product. One or more italicized words indicates an index entry or an important technical term. 1. Instructions are numbered. ✓ As are results or outcomes of these actions. 2018-03-02 Operating Instructions Force 120 page 3/20...
  • Page 4: Safety

    The manufacturer is not liable for damage caused by improper use of the device. page 4/20 Operating Instructions Force 120 2018-03-02...
  • Page 5: Transport And Storage

    Only store equipment in dry areas. Use the supplied or appropriate packaging material for storage and transport. To lift the device, use the carrying handles on the casing. 2018-03-02 Operating Instructions Force 120 page 5/20...
  • Page 6: Scope Of Delivery

    Check the scope of delivery for completeness after unpacking. Check device for visible damage. Number/component Description 1 x Force 120 1 x PowerCON True1 1 x Operating Instructions Advice Order optional accessories directly from your specialist retailer. List to be found online at www.germanlightproducts.com.
  • Page 7: Description Of Devices

    Description of devices 5 Description of devices Image 1: Description - Force 120 (back) 1 Safety eyelets 4 Display with buttons 2 D-rings/suspensions (two-sided) 5 Connections 3 Carrying handles (two-sided) 2018-03-02 Operating Instructions Force 120 page 7/20...
  • Page 8: Assembly And Connection

    Attention High air flows. Objects in the area can be damaged or damage the Force 120. Make sure that there are no light, unsecured objects up to 3 meters in front of and behind the device.
  • Page 9: Operation

    Value Description 1 - 505 DMX start address Setup Level 2 Level 3 Level 4 Level 5 Value Description Normal DMX mode High resolution Wired DMX DMX input Use wired DMX as input 2018-03-02 Operating Instructions Force 120 page 9/20...
  • Page 10: Settings

    Time after which the display blacks out after Display Blackout 1 - 10 -30 s last keystroke (auto time blackout has to be enabled) Normal Flip display up/down Display orientation Inverted page 10/20 Operating Instructions Force 120 2018-03-02...
  • Page 11: Information

    0 - 255 Speed/angle Special/ 0 - 255 control 0 - 255 Shutter DMX input monitor Dimmer 0 - 255 0 - 255 0 - 255 Green Blue 0 - 255 0 - 255 Color 2018-03-02 Operating Instructions Force 120 page 11/20...
  • Page 12: Manual Control

    Last 5 digits of the serial number. Needed Serial 0 - 99999 for correct working 0 - 128 - 255 0 - 128 - 255 LED1 Green calibration Blue 0 - 128 - 255 page 12/20 Operating Instructions Force 120 2018-03-02...
  • Page 13: Switch Off Device

    Operation 7.3 Switch off device ▶ Disconnect the device from the power supply. ✓ The device is switched off. 2018-03-02 Operating Instructions Force 120 page 13/20...
  • Page 14: Cleaning And Maintenance

    Cleaning and maintenance 8 Cleaning and maintenance Force 120 is a low-maintenance device. Depending on the operating environment, surfaces must cleaned on a regular basis. Warning Danger of electrical shock. Electric cables can cause serious injury if they come into contact with cleaning agents.
  • Page 15: Technical Data

    5 pin XLR: (+) = pin 3; (-) = pin 2; Ground = pin 1 Protection class IP20 Minimum / maximum -20 – 45 °C ambient temperature -4 – 113 °F Maximum fan speed 750 revolutions/min. Minimum fan speed 30 revolutions/min. 2018-03-02 Operating Instructions Force 120 page 15/20...
  • Page 16: Recycling/Disposal/Environmental Protection

    At the end of its service life, return the device free-of-charge to the manufacturer, point of sale or a public collection point set up for this purpose. page 16/20 Operating Instructions Force 120 2018-03-02...
  • Page 17: Contact

    Contact 11 Contact Manufacturer GLP German Light Products, Inc. 1145 Arroyo Ave., Unit A San Fernando, CA 91340 Support Online www.germanlightproducts.com To use the online support, it is required to go through a one-time registration process. Then log into the online support using your registered user account.
  • Page 18 Contact page 18/20 Operating Instructions Force 120 2018-03-02...
  • Page 19 Contact 2018-03-02 Operating Instructions Force 120 page 19/20...
  • Page 20 GLP German Light Products, Inc. 1145 Arroyo Ave., Unit A San Fernando, CA 91340 Phone: +1 818 767 8899 E-mail: Support@germanlightproducts.com Website: www.germanlightproducts.com...

Table of Contents