Page 1
Ocean Optics, Inc. 830 Douglas Ave., Dunedin, FL, USA 34698 Phone 727.733.2447 727.733.3962 8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST Ocean Optics B.V. (Europe) Geograaf 24, 6921 EW DUIVEN, The Netherlands Phone 31-(0)26-3190500 F ax 31-(0)26-3190505 E-mail: Info@OceanOptics.com...
Page 2
Every effort has been made to make this manual as complete and as accurate as possible, but no warranty or fitness is implied. The information provided is on an “as is” basis. Ocean Optics, Inc. shall have neither liability nor responsibility to any person or entity with respect to any loss or...
Page 3
Warranty Mikropack GmbH warrants to the original user of this instrument that it shall be free of any defects resulting from faulty manufacture of this instrument for a period of 12 months from the original data of shipment. There is no warranty for the bulb. This instrument should not be used for any Clinical or Diagnostic purposes.
Engineering-level documentation is located on our website at Technical → Engineering Docs. Upgrades Occasionally, you may find that you need Ocean Optics to make a change or an upgrade to your system. To facilitate these changes, you must first contact Customer Support and obtain a Return Merchandise Authorization (RMA) number.
Chapter 1 Setup Overview The following sections provide instructions on unpacking, setting up and adjusting your Fiber Optic Dual Switch (FOS) unit. 000-10000-040-02-0505...
3. Use this instrument in a clean laboratory environment. Contents Your package should contain the following: FOS-2x2-TTL unit One IC-DB15-2 interface cable for switch operation Setup Refer to Figures 1 and 2 when setting up your FOS unit. ►...
1: Setup Right Left Figure 1: Rear of FOS Unit Figure 2: Front of FOS Unit Adjusting Optical Power The FOS is factory optimized on a fiber-core-diameter of 200µm. If other core diameters are used, you can change the focal points. Refer to Figures 1 and 2 when adjusting the optical power. ►...
1: Setup Application Set-up The following photograph shows a typical FOS set-up using a NonoCalc Thin Film Reflectometry System. 000-10000-040-02-0505...
Chapter 2 FOS-2x2-TTL Specifications This section provides information on the environmental and physical specifications of the FOS-2x2-TTL. It also provides pinouts for the 15-pin connector. Note Modification of specifications and design to improve device performance are possible without notice. Operating Environment The following table provides information on optimizing the operating environment of your FOS unit.
Power Requirements 12 VDC Power Consumption Maximum 200 mA Weight Approximately 500 g Size 100 x 90 x 70 mm Pinout Information The following table contains pinout information for the FOS-2x2-TTL: Description Ground TTL Signal na = not applicable 000-10000-040-02-0505...
Chapter 3 Operating Instructions Setting the Operating Mode Operating the FOS unit requires setting its operating mode with the two switches on the unit’s front panel to the appropriate positions (see Figure 3). Figure 3: FOS Unit Switches Switch (4) Position Switch (6) Position Result MANUAL...
Index document rear of unit, 3 audience, iii purpose, iii summary, iii setting operating mode, 9 setup, 1, 2 specifications, 5 front of unit, 3 switches, 9 operating environment, 5 unpacking procedure, 2 operating mode upgrades, iii setting, 9 optical power adjusting, 3 warranty, i what's new, iii...