Ocean Optics FOS-2x2-TTL Installation And Operation Manual

Fiber optic dual switch

Advertisement

Quick Links

Fiber Optic Dual Switch
FOS-2x2-TTL
A
Installation and Operation Manual
Document Number 000-10000-040-02-0505
Offices:
Ocean Optics, Inc.
830 Douglas Ave., Dunedin, FL, USA 34698
Phone 727.733.2447
Fax
727.733.3962
8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST
Ocean Optics B.V. (Europe)
Geograaf 24, 6921 EW DUIVEN, The Netherlands
Phone 31-(0)26-3190500
F ax
31-(0)26-3190505
E-mail:
Info@OceanOptics.com
Info@OceanOpticsBV.com
Orders@OceanOptics.com
TechSupport@OceanOptics.com (Technical support)
Product
(General sales inquiries)
(European sales inquiries)
(Questions about orders)

Advertisement

Table of Contents
loading

Summary of Contents for Ocean Optics FOS-2x2-TTL

  • Page 1 Ocean Optics, Inc. 830 Douglas Ave., Dunedin, FL, USA 34698 Phone 727.733.2447 727.733.3962 8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST Ocean Optics B.V. (Europe) Geograaf 24, 6921 EW DUIVEN, The Netherlands Phone 31-(0)26-3190500 F ax 31-(0)26-3190505 E-mail: Info@OceanOptics.com...
  • Page 2 Every effort has been made to make this manual as complete and as accurate as possible, but no warranty or fitness is implied. The information provided is on an “as is” basis. Ocean Optics, Inc. shall have neither liability nor responsibility to any person or entity with respect to any loss or...
  • Page 3 Warranty Mikropack GmbH warrants to the original user of this instrument that it shall be free of any defects resulting from faulty manufacture of this instrument for a period of 12 months from the original data of shipment. There is no warranty for the bulb. This instrument should not be used for any Clinical or Diagnostic purposes.
  • Page 4 Warranty 000-10000-040-02-0505...
  • Page 5: Table Of Contents

    Unpacking the FOS Unit....................2 Contents .......................... 2 Setup ..........................2 Adjusting Optical Power ....................3 Application Set-up ......................4 Chapter 2: FOS-2x2-TTL Specifications ..........5 Operating Environment....................5 Specifications ........................6 Pinout Information ......................6 Pinout Diagram .......................... 7 Chapter 3: Operating Instructions.............9 Setting the Operating Mode ....................
  • Page 6 Table of Contents 000-10000-040-02-0505...
  • Page 7: About This Manual

    Engineering-level documentation is located on our website at Technical → Engineering Docs. Upgrades Occasionally, you may find that you need Ocean Optics to make a change or an upgrade to your system. To facilitate these changes, you must first contact Customer Support and obtain a Return Merchandise Authorization (RMA) number.
  • Page 8 About This Manual 000-10000-040-02-0505...
  • Page 9: Chapter 1: Setup

    Chapter 1 Setup Overview The following sections provide instructions on unpacking, setting up and adjusting your Fiber Optic Dual Switch (FOS) unit. 000-10000-040-02-0505...
  • Page 10: Unpacking The Fos Unit

    3. Use this instrument in a clean laboratory environment. Contents Your package should contain the following: FOS-2x2-TTL unit One IC-DB15-2 interface cable for switch operation Setup Refer to Figures 1 and 2 when setting up your FOS unit. ►...
  • Page 11: Adjusting Optical Power

    1: Setup Right Left Figure 1: Rear of FOS Unit Figure 2: Front of FOS Unit Adjusting Optical Power The FOS is factory optimized on a fiber-core-diameter of 200µm. If other core diameters are used, you can change the focal points. Refer to Figures 1 and 2 when adjusting the optical power. ►...
  • Page 12: Application Set-Up

    1: Setup Application Set-up The following photograph shows a typical FOS set-up using a NonoCalc Thin Film Reflectometry System. 000-10000-040-02-0505...
  • Page 13: Chapter 2: Fos-2X2-Ttl Specifications

    Chapter 2 FOS-2x2-TTL Specifications This section provides information on the environmental and physical specifications of the FOS-2x2-TTL. It also provides pinouts for the 15-pin connector. Note Modification of specifications and design to improve device performance are possible without notice. Operating Environment The following table provides information on optimizing the operating environment of your FOS unit.
  • Page 14: Specifications

    Power Requirements 12 VDC Power Consumption Maximum 200 mA Weight Approximately 500 g Size 100 x 90 x 70 mm Pinout Information The following table contains pinout information for the FOS-2x2-TTL: Description Ground TTL Signal na = not applicable 000-10000-040-02-0505...
  • Page 15: Pinout Diagram

    2: FOS-2x2-TTL Specifications Pinout Diagram 000-10000-040-02-0505...
  • Page 16 2: FOS-2x2-TTL Specifications 000-10000-040-02-0505...
  • Page 17: Chapter 3: Operating Instructions

    Chapter 3 Operating Instructions Setting the Operating Mode Operating the FOS unit requires setting its operating mode with the two switches on the unit’s front panel to the appropriate positions (see Figure 3). Figure 3: FOS Unit Switches Switch (4) Position Switch (6) Position Result MANUAL...
  • Page 18 3: Operating Instructions 000-10000-040-02-0505...
  • Page 19: Index

    Index document rear of unit, 3 audience, iii purpose, iii summary, iii setting operating mode, 9 setup, 1, 2 specifications, 5 front of unit, 3 switches, 9 operating environment, 5 unpacking procedure, 2 operating mode upgrades, iii setting, 9 optical power adjusting, 3 warranty, i what's new, iii...
  • Page 20 Index 000-10000-040-02-0505...

Table of Contents