Page 1
Installation Operation Maintenance Manual S Series Twin Screw Pumps W h e r e I n n o v a t i o n F l o w s www.maag.com MAAG–14000-E-02EMEA MAAG-14000-E REPLACES MAAG-14000-E-02...
S E C T I O N TA B L E O F C O N T E N T S SECTION 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 FOREWORD .
. The instructions within this manual must be thoroughly reviewed Maag S Series Pumps include 2H, 2HE, 2HM, 2HR, 2HC, 2HH, 2MPS, in their entirety and fully understood prior to pump installation, 2VE and 2VM models .
. Unless there is written permission by Maag, the pump must not be operated at higher parameters than specified . Adhering to these Prior to leaving our factory, all pumps are subjected to a thorough specifications is meant to prevent danger to persons and damage test run and performance test on a test stand .
Packing List to ensure no components are missing or damaged . The identity of any missing or damaged components must be communicated to the carrier and Maag . Damage claims should be made at the time of the receipt and check .
. This information must Option A: Weld a lug to the anchor bolt head to prevent bolt be provided to Maag engineers by the purchaser and specified turning (see Figure 4) . according to the pre-planned location of the pump installation site .
SUCTION STRAINERS NOTE: Coupling axial clearance, per specifications, should be Maag suggests that suction strainers be installed on the suction within 2 mm to 5 mm (0 .08 in . to 0 .2 in .) . If using special coupling, side of the pump at least temporarily until the new system is please consult with the manufacturer’s regulations .
Gear oil in the gear box is used to lubricate and cool timing realignment should be done while installing the pump after the gears of the pump and to splash-lubricate roller bearings . Maag following: suggests using the same type of high-grade gear oil with anti- Check coupling alignment after the base-plate has been leveled;...
. If any rubbing or binding occurs, the cause must be STEP 3 located and corrected before starting the pump . If pump is installed with a heating device, stop the heating device first, then close the sealing system after cooling . MAAG-14000-E-02EMEA S SERIES TWIN SCREW PUMPS...
• • Discharge pressure is greater than operating pressure of pump, and the recycle valve has opened. • Decrease discharge pressure. • • Mechanical seals leak. • Check and replace mechanical seal. S SERIES TWIN SCREW PUMPS MAAG-14000-E-02EMEA...
WEEKLY MAINTENANCE STEP 1 If pump is not in use for one week, open suction and discharge valves, run idle pump under power . STEP 2 Check operation of suction and discharge valves . MAAG-14000-E-02EMEA S SERIES TWIN SCREW PUMPS...
Page 15
Maag shall not be liable for damages or delay resulting from or related to defective products, nor for consequential, special or contingent damages for breach of warranty.