Hemodialysis practice arm
skin & vein replacement kit (4 pages)
Summary of Contents for Life form LF03699U
Page 1
Trapped with .3 pt overprinting stroke at this size. Fill not set to overprint. Trapping should be changed when the logo is scaled to different sizes. Set black fill to overprint if desired. “Airway Larry” AIRWAY MANAGEMENT TRAINER LF03699U INSTRUCTION MANUAL Products by NASCO...
Page 2
Anne™* brand manikins, creating a About the Simulator… valuable mega-code component. With The Life/form Airway Management ® proper care, your Life/form Airway Trainer, “Airway Larry”, is the most real- ® Management Trainer will provide years istic simulator available for the training of valuable service.
Page 3
PLEASE NOTE: NASCO recommends Next, turn the head slightly to the side to the use of the provided lubricant or a align the keyways with the slots, and pull similar vegetable-based lubricant for the head from the stand (Figure 4). the “Airway Larry”...
Page 4
® Remove the Resusci Anne™* head Connecting the Airways: and the connected section of corru- Once the head is in place, connect the gated tubing down to the valve. Install lung bag to the right bron- CPARLENE ® the Airway Management Trainer head chus by sliding the cap plug over the and hook it up to the lung system with white adapter in the bronchus (Figure 6).
Page 5
Disinfecting the Airway: To disinfect, repeat the standard cleaning procedure, but this time using a bleach solution, as specified by the Centers for Disease Control instead of soapy water. Fill the system with the solution until it reaches the corners of the mouth. Remember to start filling with the head flat, and finish with the neck slightly ele- vated to ensure that the solution com-...