Electrical installation
For choosing conductor cross section, cable style and detailed
wiring, read latest version of Yaskawa D1000 technical manual
r
s
L1 L2 L3 PE
t
PE
B
A
C
connect wiring on this terminal side!
terminal size and tightening torque
A
B
D1000 voltage detection
POWER SUPPLY
LCL-filter type
terminal size torque
terminal size torque
B84143...
mm²
Nm
mm²
G0008R176
4
0.5...1
2.5
G0016R176
4
0.5...1
2.5
G0030R176
10
1.2...1.9
2.5
G0043R176
16
2...3.6
2.5
35
5...6
2.5
G0058R176
Reading and understanding „Cautions and warnings" as
well as „important notes" in the latest datasheet version
of the dedicated LCL-filter is mandatory before
installation!
© EPCOS AG 2015
L1' L2' L3' PE
D
C
D
PE filter frame
D1000 main circuit
bolt size
torque
terminal size torque
Nm
mm²
Nm
Nm
0.4...0.8
M6
4
0.5...1
3±0.15
0.4...0.8
M6
3±0.15
4
0.5...1
0.4...0.8
M6
10
1.2...1.9
3±0.15
0.4...0.8
M8
16
2...3.6
6±0.3
0.4...0.8
M8
35
5...6
6±0.3
4/4
3-line LCL-filters
B84143G0008R176...B84143G0058R176
Characteristics
I
terminal
terminal
R
R
typ
cross section
cross section
LINE/LOAD
voltage detection
mm²
mm²
A
mW
8
4
2.5
268
16
4
2.5
98
30
10
2.5
38
43
16
2.5
26
58
35
2.5
17
Standard connection diagram
Standard connection diagram
RCD
or
MCCB
L1
L1
Three-
L2
Phase
L2
Power
L3
Supply
L3
PE
D1000
voltage detection
D1000
R/L1
CIMR-Dx4A0005xxx...
CIMR-Dx4A0040xxx
S/L2
T/L3
r1
s1
t1
Installation guide
Approx.
LCL-filter type
Converter type
weight
CIMR-
kg
9
B84143G0008R176 Dx4A0005xxx
18
B84143G0016R176 Dx4A0010xxx
28
B84143G0030R176 Dx4A0020xxx
37
B84143G0043R176 Dx4A0030xxx
64
B84143G0058R176 Dx4A0040xxx
LCL-filter
D1000
B84143G0008R176...
main circuit
B84143G0058R176
L1'
L2'
L3'
r
s
t
Drive
+
+
U
V
-
-
W
1/4
V62187-Z10-C271-1-7406
M

Advertisement

loading

Summary of Contents for TDK B84143G0008R176

  • Page 1 Converter type cross section cross section weight CIMR- LINE/LOAD voltage detection mm² mm² L1 L2 L3 PE L1' L2' L3' PE B84143G0008R176 Dx4A0005xxx B84143G0016R176 Dx4A0010xxx B84143G0030R176 Dx4A0020xxx B84143G0043R176 Dx4A0030xxx B84143G0058R176 Dx4A0040xxx Standard connection diagram Standard connection diagram LCL-filter D1000 MCCB B84143G0008R176...
  • Page 2 Mechanical installation convection space mounting direction dimensions keyholes on top side Ø Ø Ø Ød (2x) keyholes on top side Ød (2x) ØD (2x) LCL-filter type ±5 B84143... G008R176 G016R176 G030R176 G043R176 G058R176 Tightening torque for fixing screws: For standard screw connection to the filter attachment it is referred to state-of-the-art solutions, as the tightening torques depend on the nominal size, length, strength class, illustration with optional cover corrosion protection and lubricants...

This manual is also suitable for:

B84143g0043r176B84143g0016r176B84143g0030r176B84143g0058r176