These instructions are provided to familiarize the user with the seal and its
designated use. The instructions must be read and applied whenever work
is done on the seal, and must be kept available for future reference.
Safety Instructions
1. The following designations are used in the installation instructions to
highlight instructions of particular importance.
NOTE:
Refers to special information on how to install or
operate the seal most efficiently.
Refers to special information or instructions directed
ATTENTION
towards the prevention of damage to the seal or its
surroundings.
Refers to mandatory instructions designed to
!
prevent personal injury or extensive damage to the
seal or its surroundings.
2. Installation, removal, and maintenance of the seal must be carried out
only by qualified personnel who have read and understood these
installation instructions.
3. The seal is designed exclusively for sealing rotating shafts. The
manufacturer cannot be held liable for use of the seal for purposes
other than this.
4. The seal must only be used in technically perfect condition, and
must be operated within the recommended performance limits in
accordance with its designated use set out in these installation
instructions.
Before Starting the Equipment
1. Check the pump at the coupling for proper alignment of the driver
or motor.
2. Ensure that the gland plate nuts/bolts are securely tightened
according to the pump manual instructions, and that all screws
are securely fastened.
3. Complete the assembly of the pump, and turn the shaft (by hand if
possible) to ensure free rotation.
4. Consult all available equipment operating instructions to check for
correctness of all piping and connections, particularly regarding seal
recirculation/flush, heating or cooling requirements, and services
external to the seal.
This mechanical seal is designed to operate in a liquid
ATTENTION
so the heat energy it creates is adequately removed.
Therefore, the following check should be carried out
not only after seal installation, but also after any
period of equipment inactivity.
5. Check that the seal chamber fluid lines are open and free of any
obstruction, and ensure that the seal chamber is properly vented
and filled with liquid — refer to the pump instruction manual.
TYPE 5610V/5610VQ
SINGLE O-RING CARTRIDGE SEAL
Installation, Operation & Maintenance Instructions
These instructions are for the installation and operation of
ATTENTION
a seal as used in rotating equipment and will help to avoid
danger and increase reliability. The information required
may change with other types of equipment or installation
arrangements. These instructions must be read in
conjunction with the instruction manuals for both the
pump and any ancillary equipment.
If the seal is to be used for an application other than that originally
intended or outside the recommended performance limits, John Crane
must be contacted before its installation and use.
Any warranty may be affected by improper handling, installation, or use
of this seal. Contact John Crane for information as to exclusive product
warranty and limitations of liability.
If questions or problems arise, contact your local John Crane representative.
or the original equipment manufacturer, as appropriate.
John Crane mechanical seals are precision products and
ATTENTION
must be handled appropriately. Take particular care to
avoid damage to lapped sealing faces and to flexible
sealing rings. Do not excessively compress the seal
before or during installation.
5. If the pumped fluid is hazardous or toxic, appropriate precautions
must be taken to ensure that any seal leakage is adequately
contained. Further information on sealing hazardous or toxic fluids
should be obtained from John Crane prior to seal installation.
6. Fluorocarbon components should never be burned or incinerated
as the fumes and residues are highly toxic. If fluorocarbons are
accidentally heated above 400˚C/750˚F, they can decompose.
Protective gloves should be worn as hydrofluoric acid may be present.
7. PTFE components should never be burned or incinerated as the
fumes are highly toxic.
Dry running — often indicated by a squealing noise from
ATTENTION
the seal area — will cause overheating and scoring or
other damage to the sealing surfaces, resulting in
excessive leakage or a much shortened seal life.
Before startup, ensure that all personnel and
!
assembly equipment have been moved to a safe
distance so there is no contact with rotating parts
on the pump, seal, coupling, or motor.
WARNING:
Seal installation should be handled only by qualified
personnel. If questions arise, contact the local
John Crane representative. Improper use and/or
installation of this product could result in injury to
the person and/or harmful emissions to
the environment, and may affect any warranty
on the product. Please contact the company for
information as to exclusive product warranty
and limitations of liability.
1
PAGE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5610V and is the answer not in the manual?

Questions and answers

Summary of Contents for John Crane 5610V

  • Page 1 Any warranty may be affected by improper handling, installation, or use of this seal. Contact John Crane for information as to exclusive product warranty and limitations of liability. If questions or problems arise, contact your local John Crane representative.
  • Page 2: General Instructions

    Seal Arrangement 1. Study the engineering layout drawing to confirm the proper seal arrangement for the pump being used. Types 5610V and 5610VQ seals are designed for versatility and can be assembled in various ways. The following instructions describe the standard configurations.
  • Page 3 PAGE SINGLE O-RING CARTRIDGE SEAL Installation, Operation & Maintenance Instructions Type 5610V Single O-ring Cartridge Seal Assembly (continued) 15. Carefully rotate the gland plate until through holes in sleeve are lined up with the collar set screws. 16. Carefully press down on gland plate and install snap ring over the end of sleeve.
  • Page 4 TYPE 5610V/5610VQ PAGE SINGLE O-RING CARTRIDGE SEAL Installation, Operation & Maintenance Instructions Type 5610V Oversize Bore Single Cartridge Type 5610VQ Oversize Bore Single Cartridge Dimensional Data (inches) Dimensional Data (inches) Seal Min. Seal Min. Size/D1 Min. Max. N Turn Diam.
  • Page 5: Maintenance

    It is recommended that used seals are returned to a John Crane service nated and made safe prior to commencing work. location, as rebuilding to as-new specifications must be carried out by Remember, fluid is often trapped during draining and qualified personnel.
  • Page 6: Ordering Information

    1. Cartridge seal size = solid shaft or sleeve outside diameter (OD). Primary Ring Carbon Graphite 2. Select single (5610V) or single with quench (5610VQ) arrangement. Silicon Carbide (optional) 3. Determine whether standard or enlarged seal chamber configuration Nickel Binder Tungsten Carbide (optional) is required.
  • Page 7 TYPE 5610V/5610VQ PAGE SINGLE O-RING CARTRIDGE SEAL Installation, Operation & Maintenance Instructions...
  • Page 8 Fax: 65-6518-1803 If the products featured will be used in a potentially dangerous and/or hazardous process, your John Crane representative should be consulted prior to their selection and use. In the interest of continuous development, John Crane Companies reserve the right to alter designs and specifications without prior notice.