Eastern Energy Smart Sensor Intell Instruments Pro AS8901 Manual

Oxygen monitor

Advertisement

Quick Links

Contact :
EASTERN ENERGY CO.,LTD. (HEAD OFFICE)
40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170
Tel: 0-3844-6117, Fax: 0-3844-6200
Email: sale@ete.co.th
Web: www.eastern-energy.com
EASTERN ENERGY CO.,LTD. (RANGSIT BRANCH)
801/192 Moo.8 Kukot, Lamlukka, Pathumthani 12130
Tel: 0-2531-3833, Fax: 0-2531-3833
Email: sale@ete.co.th
Web: www.eastern-energy.com
CONTENTS
1.NOTICE BEFORE USE
Cautions and warnings
---------------------------(01)
---------------------------------------- (02)
Unit packing
Product specifications
--------------------------- (02)
Outlook of the instrument
------------------------(03)
Introduction
---------------------------------------- (03)
2.OPERATION MANUAL
Instrument operation
----------------------------- (04)
Oxygen
monitoring mode
------------------------ (04)
Zero calibration mode
---------------------------- (05
Peak value mode
----------------------------------(06)
Low alarm setting mode
------------------------- (07)
-------------------------(08)
High alarm setting mode
Instrument calibration mode
Accressory AS8930 sampling pump
3. OTHERS
Mantainance
---------------------------------------(11)
Warranty
------------------------------------------- (12)
Manufacturing statements
-----------------------(12)
Encloures
-------------------------------------------(12)
-------------------- (09)
-----------(10)
OXYGEN MONITOR
Version number:AS8901-0-1
The effect of oxygen-deficient and oxygen-enriched atmospheres
The concentration
Symptoms (atmospheric pressure)
of oxygen(%)
Deadly, 6 minutes(Absolutely airtight environment,
such as hyperbaric oxygen chamber
Deadly, can be cured after 45 minutes treatment.
(Absolutely airtight environment, such as hyperbaric
oxygen chamber)
Reduce efficiency, and lead to problems of head,
lung and circulation system
Shortness of breath, loss of judgment, purple lips
governance loss, syncope, unconscious, pale,
nausea and vomiting
8 minutes, blood pressure, weak heartbeat,
mouth breathing, quickly stopped breathing
40 seconds, convulsions, respiratory arrest, death
The above parameters are for reference only
-13-
Model AS8901
%
Rich oxygen
Normal
Minimum

Advertisement

loading
Need help?

Need help?

Do you have a question about the Smart Sensor Intell Instruments Pro AS8901 and is the answer not in the manual?

Questions and answers

Summary of Contents for Eastern Energy Smart Sensor Intell Instruments Pro AS8901

  • Page 1 : Model AS8901 OXYGEN MONITOR Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax: 0-3844-6200 Email: sale@ete.co.th Web: www.eastern-energy.com EASTERN ENERGY CO.,LTD. (RANGSIT BRANCH) 801/192 Moo.8 Kukot, Lamlukka, Pathumthani 12130 Tel: 0-2531-3833, Fax: 0-2531-3833 Email: sale@ete.co.th...
  • Page 2 、NOTICE BEFORE USE 3. 2 WARRANTY * AS8901 Oxygen gas Monitor is warranted to be free from 1.1 CAUTIONS AND WARNINGS defects in material and workmanships for a period of one year after purchase. * This warranty not includes the sensor and battery pack The user need to read and follow the procedures and after 6 month purchase period.
  • Page 3: Operation Manual

    1.4 OUTLOOK OF THE INSTRUEMENT 9. If it shows F , it means the calibration is failed, need to recalibrate again. 10.If no standard gas is used, please do not enter to this instrument calibration mode, for the pre-set value will be easy to be deleted. 2.8 ACCESSORY AS8930 SAMPLING PUMP * The AS8930 external sampling pump is available to work 1.5 INTRODUCTIONS...
  • Page 4 Contact : 6. Depress the button for re-enter this setting mode again for further adjusted setting if required. EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 7. Pressing the button to move the setting to high alarm 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 setting mode.