Note: There is an increased skid risk in case of spilled/leaked out lubricants. They are to be removed at once properly. Safety sign according to DIN 4844, warning about skid risk. BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
Leakages (e. g. from the shaft seal) of hazardous goods to be delivered (e. g. explosive, toxic, hot) are to be removed in such a way that there is no danger to persons and environment. Legal rules are to be observed. BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
Cross section view of a PVB distributor Overall view of distributor Cross section: outlet fittings Inlet fitting Port fitting non-return valve Ø 6 mm Setscrew and ball Cross section of metering piston Metering piston Motion indicator with protective cap BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
Page 5
The flow of lubricant inside the distributor must be guaranteed; otherwise the distributor will become blocked. The following illustration shows the two alternatives for connecting and locking distributor outlets. BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
Page 6
In addition the motion indicator can be read electrically using a proximity switch. In this case it must be ensured that the same side is always evaluated using the control mechanism. Visual monitoring (160 bar) Electrical monitoring (160 bar) Pressure resistant electrical monitoring (350 bar) Note: Operating pressure 350 bar in versions without monitoring BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
On an individual basis we will be happy to test your lubricant in our facilities for ability to supply. Connectable pipelines: Inlet (Port thread: G 1/8) ............................Ø 6/8/10 mm Outlet (M 10x1, Special fitting) ............................Ø 6 mm Measurement and weight ............................see table on page 5 BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
Page 8
Temperature range : ................................-25 to +70°C Short-circuit protection : ................................clocked Connection : ......................PUR-cable / 0.3 m with M12 plug-in connector Housing material : ....................PEEK (polyether-ether ketone) / V4A (1.4571) Circuit diagram and dimensions: BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
Inlet fitting for Ø.6 mm pipe and outlet fittings ......01 Inlet fitting for Ø 10 mm pipe and outlet fittings ...... 02 No fittings (Special fittings must be selected from the Accessories Table page 12/13) ............. 03 BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
If a progressive system consists of main and sub-distributors, only the main distributors are monitored electrically as a rule. Visual monitoring is sufficient for the sub-distributors. The following illustration shows a typical system design with PVB main and sub-distributors. BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
Page 11
In most applications 160 bar are sufficient. We can calculate the system pressure for you with the help of our comprehensive rheometer database. If necessary we can offer you tests specially for your type of grease. BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
Welt-on plate for installation size up to 16 Auslässe (L=165) 74362P049 Welt-on plate for installation size up to 18 Auslässe (L=180) 74362P050 Welt-on plate for installation size up to 20 Auslässe (L=195) 74362P051 * 2 pieces per each divider required BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
The pipeline ports are thus on the upper side, which makes it easier to fit the pipes. o The distributor must be mounted in a stress-free position on a flat surface. o Weld-on plates (optionally available) must only be welded on without the distributor fitted. BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
Page 14
The distributor is designed for continuous operation. Care should be taken during the entire operating phase that the specified operating pressure and temperature range are not exceeded. Only approved lubricant which is free of contamination may be used. Disassembly: The distributor must only be disassembled when it is at a standstill and depressurized. BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
Reconnect the disconnected outlet fittings one by one and carry out a test run after reconnecting each one. This makes it possible to isolate the malfunction and find the affected line. BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
- integrated motor (24 V or 230 V) - 4, 8, 12, 20 litre container - connectable to PVB distributor - integrated control system (optional) - up to 300 bar Other pumps are available for specific applications upon request BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_PVB...
Need help?
Do you have a question about the PVB series and is the answer not in the manual?
Questions and answers