Server Technology CW-16V Specification Sheet

Cw-16v series sentry switched cdu

Advertisement

Quick Links

Key Features
> Remote Power Management:
Power cycle individual power
outlets, or groups of power
outlets, to remotely reboot
servers and network devices,
anywhere in the world. Or,
power-off unused power
receptacles
> High Power Distribution: 120V,
208V, or 230V power; 20 or
30-Amp power input feed
options
> High Density: Single power
input feed; 16 outlets per
enclosure
> IP Access & Security: Web
interface, SSL, SSH, Telnet, SNMP
or RS-232 access
> Add an Expansion Module:
Daisy chain the Switched CDU
Expansion Module (CW/CX) for
power management of separate
power circuits from a single IP
address
> Environmental Monitoring:
Each Switched CDU supports two
temperature & humidity probes
and reports conditions thru the
Web interface
> Enterprise View: View and
access up to 1,000 Switched
CDUs from one Web interface**
> SNMP Traps: Provide automated
alerts for power and
environmental conditions
> Input Current Monitor:
Precisely measure the aggregate
current draw (in amps) on each
power circuit. On-site
verification of the input current
with the LED digital display.
Remote verification via browser
or serial screen.
> Power-up Sequencing: Prevent
an in-rush power overload
Sentry : Solutions for the Data Center Equipment Cabinet
Sentry Switched CDU
CW-16V
High-Density Power Distribution
The Switched CDU's combine remote configuration and management
with power distribution and power and environmental monitoring.
Reboot a single or dual-power server with one command. Receive
SNMP alerts when power or environmental conditions exceed
thresholds. Assign users specific access rights to designated outlets or
groups.
Only the Switched CDU products provide the flexibility needed for all
data centers and remote sites, including power requirements for
high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & SSH
security; and SNMP-based input current monitoring.
The Switched CDU also supports Enterprise View PDU Manager.
This gives the engineer the ability to manage a large installation of
Networked CDUs from one location, view and access up to 1,000
Switched CDUs from a
Additional Benefits:
Branch Circuit Protection
The Sentry CDU Family meets the new UL 60950-1
requirement for branch circuit protection.
Attention!
providing overcurrent protection with UL-listed Bussman SC fuses for
each branch circuit.
Input Current Monitoring
The CDU's exclusive True RMS current monitoring is critical
to preventing overloads in high-density computing
environments. LED digital displays on the CDU enclosure
report the input current of each phase or branch circuit.
Temperature and Humidity
The Switched CDU supports two external probes. Each of
these probes measure both temperature and humidity.
Receive SNMP-based alert notifications when conditions
exceed defined thresholds.
single web interface.
The Sentry CDU products meet the above criteria by
CW-16V1

Advertisement

loading

Summary of Contents for Server Technology CW-16V

  • Page 1 Sentry Switched CDU CW-16V Key Features > Remote Power Management: Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-off unused power receptacles > High Power Distribution: 120V, 208V, or 230V power;...
  • Page 2 > CX-16V2-L30M > CX-16VE-C20M > CX-16VE-P32M © Server Technology, Inc. 10/2006 version. Information in this document is subject to change without notice. Sentry is a trademark of Server Technology, Inc. Patent # 7,043,543. Patent Pending. Printed in US. Available Input Amperage...

This manual is also suitable for:

Cw-16v1-c20mCw-16v1-l30mCw-16v2-c20mCw-16v2-l30mCw-16ve-c20mCw-16ve-p32m