WIRING DIAGRAM TBS V .......... 15 TABLE OF AUTHORITIES For TBS-V Programming ... 8 Specifications Model: TBS-V simple touch iced tea brewer with automatic dilution Description & Features: • Easy to use settings • Usable with three to five gallon dispensers.
3. Plug the unit into the appropriate 15 or 20 amp circuit. Use a dedicated circuit for brewing equipment. 4. An electrical diagram is located in the User’s Guide and online at www.fetco.com. 5. The installation must comply with applicable federal, state, and local codes having jurisdiction at your location.
DO NOT operate this brewer until the hot water tank is filled with water Damage to the heating element or brewer will result if started when dry. To start up this TBS-V iced tea brewer: 1. Place brewer on a solid, level counter top, near an electrical outlet and water main.
Page 5
The brew basket has filter paper and tea. Brew basket handle is The Start button light ring will glow steady WHITE oriented to the RIGHT TBS-V is “Ready To Brew” with factory set defaults 3-Add paper and loose tea to brew basket. Dilution Assembly The Specialty Tea guidelines are 3 oz.
Programming Adjustments See bottom of page 7 for how to access programming. -Advance through the SETTINGS by pressing the START button. -Advance through the PROGRAMMING range by pressing the black button on the control board. -SAVE settings by holding down the START button for five seconds. Settings not SAVED will be lost on startup SETTINGS Programming Factory set...
Calibrations -Set the volumes for the brew & dilution valves to adjust for taste, profile and for over/under potting. Brew volume and Dilution volume can be individually adjusted by user -Set volumes and brew water temperature on the control board. -The volumes are set by timers that control how long the brew and dilution valves are open.
Table of Authorities for TBS-V Programming Display Description Default Increment Brew Time (R) Right Batch Dilution Time (R) Parameters Dilution Delay (R) Brew Time (L ) Left Batch Dilution Time (L ) Parameters Dilution Delay (L) Tank Set Point Temperature Configuration.
-Control board LED5-“heartbeat” slowly dims/brightens when normal Error codes must be cleared! Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice FOR OPERATOR SAFETY This appliance is for commercial use only. Commercial cooking equipment may be unsafe for household use.
Page 10
Replacement Parts Drawing TBS-V Dual and Single Drawing 1101.00515.00...
LABEL, WARNING "TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE" 1063.00016.00 POWER CORD, 120VAC W/NEMA 5-15P PLUG 1005.00030.00 WELDING, DOME SPRAY CUTTER, 6 HOLES (Ø.078), TBS-V B013000G2 BREW BASKET ASS'Y ROUND, DUAL MODEL ONLY B020000G2 BREW BASKET ASS'Y SQUARE, SINGLE MODEL ONLY 1401.00163.00...
Page 12
TBS-V Hot Water Tank Parts List COMPLETE TANK TOP ASSY, TBS-V, 1680W/120VAC Part Number 1102.00396.00 Hot Water Tank Capacity1.6 gallon 6.0 L OPEN Leave open for use PINCH SHUT To drain tank & service brewer Tank Drain The water tank must be drained before maintenance procedures, and when the unit is to be relocated or shipped 1.
Page 13
Replacement Parts List for TBS-V Hot Water Tank Hot Water Tank Parts List: TBS-V, 1689 W/120VAC PART NO DESCRIPTION 1114.00158.00 WELDMENT, TANK COVER, TBS-V 1107.00041.00 HEATER ASS'Y., IMMERSION, 1680W/120VAC, TBS-V 1024.00062.00 GROMMET, SHORT, SILICONE, LEVEL AND TEMP PROBE 1102.00161.00 PROBE ASSEMBLY, TEMP. AND LLC, 8" LONG 1024.00051.00...
TBS-V Brew Basket Parts List TBS-V has two brew basket types: Square type for TBS-V Single Round type for TBS-V Dual brewer Round ty pe f or Square ty pe f or TBS-V Dual brewer TBS-V Single brewer Ref# Part Number Description 1023.00289.00...