INFORMATION CONCERNING YOUR BOILER
You are the owner of a Malvern High Efficiency Condensing Boiler and due to the
way it works it will appear to produce a lot of steam from the terminal; this is harmless
vapour and quite normal. The boiler requires a drain to be permanently connected,
your installer has done this, it must not be disconnected or removed. The Installer
should also have left you your
Logbook. The Gas Safety (Installations
and Use) Regulations makes it illegal for gas appliances to be installed or serviced
by persons not CORGI Registered Operatives. All Registered Installers carry a
CORGI ID card and have a registration number and this should be recorded in your
Logbook. You can check your installer is CORGI registered by calling CORGI direct
on:- 01256 372300
IMPORTANT: DO NOT DISTURB APPLIANCE CASE.
ELECTRICAL SUPPLY TO YOUR BOILER
The boiler must be connected to a 230v ~ 50 Hz supply with a 3 Amp fuse rating.
THE APPLIANCE MUST BE EARTHED.
TO IGNITE YOUR BOILER
With the Electricity supply switched on, the power lamp will be on. When the
system programmer and thermostats are in a demand position and the front panel
boiler thermostat fully clockwise, the boiler running lamp will be lit and the boiler
will start automatically. The running lamp will go out when the system thermostats
are satisfied or if the programmer is off.
If the boiler fails to start and the lockout lamp is lit reset by turning the boiler
thermostat to off then back on again.
If the boiler does not start after using the reset allow the boiler to cool, then reset
again. If this still does not succeed in getting the boiler to run, or if a fault is suspected
turn the boiler and supply off and call the assistance of a Corgi registered Engineer.

Advertisement

loading

Summary of Contents for Malvern Tentwenty

  • Page 1 INFORMATION CONCERNING YOUR BOILER You are the owner of a Malvern High Efficiency Condensing Boiler and due to the way it works it will appear to produce a lot of steam from the terminal; this is harmless vapour and quite normal. The boiler requires a drain to be permanently connected, your installer has done this, it must not be disconnected or removed.