9. GPRS/3G/LTE Module LED Indicator (Red) — ON: Off-hook / Waiting retry pause / Ready to enter Programming Mode — When power is supplied to CTC-1052, (before entering PIN code) the LED will light up for 5 seconds. — FLASH:...
In addition to the adapter, there is a — A special telephone cord to connect rechargeable battery inside CTC-1052, CTC-1052 and your phone unit for which serves as a back-up in case of a Local Programming (optional). power failure.
SIM card firmly to secure it. 1.5. Compatible with Climax’s SIM Card will delete its SMS message whenever the CTC-1052 is powered on. SMS Editor CTC-1052 is compatible with Climax’s SMS To remove SIM card: Editor, which is designed to facilitate SMS remote programming via a PC.
This prompt will be repeated three times if no action continutes. PIR Sensor ----- PIR 6. If no action after 5 minutes, the CTC-1052 Smoke Detector ---- SD will automatically exit Local Learning Mode Carbon Monoxide Detector---- CO ...
#. By using Command 41, you can set the number of rings for CTC-1052 to answer (00-Rings is Step 4. CTC-1052 will emit 2 short beeps and set as factory default). the red LED starts to flash, indicating it is in Programming Mode.
Step 1. Dial CTC-1052 and hang up after first 2 3.2. Programming Your 1052 rings, wait for another 8-20 sec then call again. CTC-1052 will answer the How to enter Commands? call on the first ring. You will enter the...
Page 10
Likewise, you can erase the respective 2 or 4 Tel. Numbers, by following the Step 6. CTC-1052 will emit a short beep, above procedure. indicating successful programming. The maximum interval between key strokes is 2 minutes. Otherwise, commands will be ignored...
Page 11
#5 and/or #6. Tel & 5 GPRS. #s (15) When multiple Tel. numbers selected, CTC-1052 will always dial in Tel & 6 GPRS. #s (16) respective programmed order. The latest Command (05-06) setting(s) & 3 Tel. #s...
Page 12
Method Ringer Enable for Incoming Calls (0), Contact ID, is set as factory default for CTC-1052 can be programmed to emit a all 4 telephone Numbers. ring tone as an audio alert, or silent for incoming calls. <NOTE>...
Page 13
CTC-1052 can be programmed to emit Command 67 (Help Arrived Timer), Fault Alert Beeps every 30 seconds from CTC-1052 will send the alarm report to AC Failure. summon help again and inform the Monitoring Center that no help has...
Page 14
Command 38 Silent Mode Follow-On & Call-Back Function CTC-1052 can be selected to operate in The Command is available for Digital Silent Mode. This will mute all normal Reporting Methods (when Command #20 - operation warning beeps, guard time #24 is set as (0), (1) or (2)) tone and key tone.
Page 15
Guard Time is elapsed. Auto Answer for Remote Programming <NOTE> CTC-1052 can be programmed to auto answer incoming phone calls after a pre-set The Guard Time Delay time from number of rings have been reached. The...
Page 16
Periodic Test Call The Mobility Timer counting down can be reset by: CTC-1052 can be programmed to make test Pressing the Green Reset Button calls periodically from (00) (no test call) to on CTC-1052, or, every (1) - (7) or 30 days:...
Page 17
(Speech mode). It It is used to select the Follow-On Choice for can be set from (01) (1 minute) - (10) (10 CTC-1052 after it has made a report to the minutes). Monitoring Center. After reporting, CTC-1052 can wait for...
Page 18
(Enable) Whenever programming mode Factory default is set as (0) OFF. accessed, CTC-1052 will reset the Off- Set timer. <NOTE> Command 49 If this function is disabled, the system will not check the entered SIM Card PIN Supervision Code set by Command 62.
Page 19
1 to 5. The higher the value, the Time Delay time for fall sensor. louder the voice. Factory default is set as (3) for Two-Way mode. CTC-1052 can be programmed to delay alarm reporting triggered by a fall detection Please refer to programming command from (00) (instant reporting) to (99) seconds.
Page 20
If help has not arrived after sending the report is made (meaning the reset button alarm report for 4 times, CTC-1052 will dial has not been pressed before the timer the telephone number programmed by expires).
Page 21
Command 77 Speech Report ACK Command 93 A two-way communication is established Learn-In Silent Pendant when a call is made from CTC-1052 to the <NOTE> Monitoring Center by sending out a speech report. This command is not available in ...
Page 22
Programming mode. CTC-1052. Step 3: CTC-1052 will emit 2 beeps to If no signal is received within 20 indicate that Silent Pendant is learnt- sec, CTC-1052 will emit a long beep in successfully.
Command 98 3.3. SMS Remote Programming Factory Default Reset To Reset CTC-1052 to factory default <NOTE> settings, enter (98) and then (#). Prior to procced, please be reminded to After one short beep, continue by entering change the language setting of your mobile () and then end with another (#), one...
Answer Numbers. If a user calls the Control Panel using an auto-answer number, the Control When the system is in Idle Mode, CTC-1052 is Panel will pick up the call and instantly open up ready to execute the following functions: a two-way communication with the caller.
ON. Expired Report, but the Mobility timer still not be reset, when reaching next pre-set time, the CTC-1052 will emit a beep at 4.1.5. Devices Low Battery every 5 minutes to notify the user for 30 ...
Step 3: Release the Reset Button when you 0 = number to substitute hear the last long beep; a short beep After this is completed, Country Code “886” will sound to indicate the mobility will be replaced by “0”. function is disabled. <NOTE>...
(for Speech Reporting programmed reporting method. If Call Method). Progress Tone is set as On, dailing tones will be heard once the CTC-1052 goes off- When the first reporting failed, and the hook. Control Panel retries. Control...
Help Arrived Mode after GPRS reporting. Please refer to Help Arrived Upon receiving the correct Access Code Mode below. and the (#) key, CTC-1052 will then open a Full-Duplex Communication to allow the caller to communicate directly. 4.2.2. Digital Reporting Method ...
Page 29
DTMF keys for over 1 second to enable 20 & 10 seconds before the Follow-On the function you desire. period expires, CTC-1052 will emit two beeps to alert both the user and the Monitoring Center Personnel. Follow On Operation ...
COMMUNICATION The Red Help Button will stop End a Call: enter (5) or (0) to HANG flashing and CTC-1052 will return to UP or put the handset back into the idle mode base cradle. ...
If Speech Reporting Method is selected, report sequence: GPRS #1, GPRS #2, Tel. after dialing, CTC-1052 will open a two-way #1, Tel. #2, Tel. #3 to Tel. #4. voice communication between the Call ...
(e.g. Digital), the panel will range. consider report method You can conduct Walk Test in CTC-1052 under successful if reporting to one of the 3 different modes as listed below. destinations succeeds. Control Panel will completely stop reporting to this report 4.3.1.
Step 1. Press the Test button of the devices Step 1. Press the Green Reset Button mentioned above (SD, CO, IR, WS), once. and a signal will be sent to CTC-1052 indicating it is ready to conduct Walk Step 2. Within 5 seconds, press Pendant Test.
And is explained in the following table: 147 - Sensor Supervisory Failure Where When CTC-1052 is unable to receive = 4 Digit Account number (0-9) ACCT the signal transmitted from the Wrist Transmitter for a pre-set period by = Message Type, 18H.
When CTC-1052 receives kiss-off from D#1012 - Global test & Periodic test Monitoring Center for opening Speech report channel. When CTC-1052 reports Global Test to 611 - Global test monitoring Center. When CTC-1052 reports Global Test to ...
555556558 - Panel Low battery / Panel Battery Disconnection D#1019 - Panel AC Failure When CTC-1052 is under Low Battery When AC power fails for more than 10 status, the Green LED flashes every 2 seconds, Green LED flashes every seconds.
Page 37
When the device Low Battery status, is restored. 155555517 - SD or CO emergency When Smoke Detector (SD) triggered or Smoke Detector’s test button is pressed. When Carbon Monoxide Detector (CO) triggered Carbon Monoxide Detector’s test button is pressed. ...
5.4. CTC-1052 Programming Command Table TERM DTMF DTMF DTMF COMMAND OPERATION DEFAULT CHARACTER NATO COMMANDS Telephone number 1 No number Telephone number 2 No number Telephone number 3 No number Telephone number 4 No number Telephone number & GPRS/IP for alarm report...
Page 39
DTMF DTMF TERMI- DTMF COMMAND OPERATION DEFAULT CHARACTER NATOR COMMANDS Mobility time Mobility time 00= Disable, 01 - 36= 1 - 36 Hours disable Follow-On Choice, 0 = Wait command, Two-way voice 1 = Listen, 2 = Two way voice communication communication Follow-On mode &...
5.5. CTC-1052 SMS Remote Programming Command Table If the SMS Keyword is set as PROG, and Access Code is set as 1111 (factory default). CORRESPON- DING DTMF ITEM COMMAND EXAMPLE & USAGE DEFAULT CHARACTER COMMANDS PROG 1111 KEYWD:IPOG Keyword...
Page 41
Ringer PROG 1111 ENRIN:0 enable for ENRIN To enable/disable ring tone for incoming calls 0 = Disable incoming 0=Disable, 1=Enable calls PROG 1111 FAUTA:0 Audible fault FAUTA To enable/disable audible fault alert 0 = Disable alert 0=Disable, 1=Enable PROG 1111 HELPA:0 Help arrived HELPA To enable/disable help arrived signalling...
Page 42
PROG 1111 SPKVL:2&1-5 To set a communication channel: 2=Two Set speaker SPKVL volume To set the speaker volume with a number, ranging Two way: 3 1-5.The higher the value, the louder the voice. Default is set as (3) for two-way mode. PROG 1111 MICSN:1-5 To set the microphone volume with a number, ranging ...
Page 43
Reset to factory FTSET PROG 1111 FTSET:YyS default 3G/LTE RSSI (3G Version GRSSI PROG 6336 GRSSI? Only) PROG 1111 DEVDL:SCMD To delete devices learnt into the panel. Delete DEVDL SCMD: Device 80 = delete All Devices. PROG 1111 DEVAD:SCMD,ID PROG 1111 DEVAD:94010203A001 To add devices into the panel SCMD: Add Device...
Page 44
message sent by the cell phone. SMS remote programming command can only be sent in the standby mode. The SMS command is successfully set after getting a confirmation message.
Page 45
Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15, Part 22, Part 24, and Part 27 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Page 46
Industry Canada Statement This device complies with Industry Canada RSS-130, RSS-132, RSS-133, RSS-139 standard. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le pr ésent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.