Do you have a question about the BeneCheck and is the answer not in the manual?
Questions and answers
Summary of Contents for General Life Biotechnology BeneCheck
Page 1
Meter (Front Side & Back Side) / BeneCheck Messgerät Messgerät (Vorderseite & Rückseite) / Kit Medidor BeneCheck Medidor (Parte delantera y parte trasera) / Kit de l’Appareil BeneCheck Appareil (Face Avant et Face Arrière) Battery Test Port Batterie Test-Port Puerto de análisis Batería...
Page 2
LCD Screen Display: Information and test result display LCD-Displayanzeige: Anzeige von Informationen und Testergebnissen Visualización de pantalla LCD: Visualización de información y resultados de prueba Affichage de l’Écran LCD: Affichage de l’information et du résultat de test Result Area / Messergebnisse/ Zona de resultado/ ①...
Page 4
Labelling and Information / Etikettierung und Informationen / Etiquetado e información/ Etiquetage et Information • In-vitro diagnostic • In-Vitro-Diagnostik • Use by • Verwenden bis • Diagnóstico in vitro • Diagnostic In-vitro • Fecha de caducidad • Utiliser avant • Lot number •...
Chapter 1 Introduction ................. 1 Chapter 2 Setting the Meter Installing/ Replacing the Batteries ............2 Set the Date and Time ..............2 Code the Meter................2 Chapter 3 How to Perform a Test Perform the Test ................3-5 Alternate Site Testing (AST) ............5-6 Chapter 4 Meter Memory Function ..............
Introduction Chapter 1 Introduction Please read carefully before using meter kit, and consult healthcare professional before making any important medical decision. Please contact your local customer service for further assistance with the product. Normal Environmental Conditions This meter designed under the following conditions: •...
Setting the Meter Chapter 2 2.1 Installing/ Replacing the Batteries This meter uses AAA battery * 2. Please remove the plastic tab under the battery before using. Note: Dispose the batteries according to your local environmental regulations. 2.2 Set the Date and Time Press “S”...
How to Perform a Test Chapter 3 Materials you need to perform a test: BeneCheck Meter/ BeneCheck Test Strip/ Lancing Device/ Lancets/ Tissue or Cotton Ball with 75% Ethanol or Disinfection Wipes 3.1 Perform the Test • Wash and clean your hands with disinfection wipes, and make sure your hands are dry before testing.
Page 9
Make sure the Pull the sliding Press the release Wipe off first drop Touch the blood code number is barrel till it clicks. button to sample. of blood and start sample with strip. correct. sampling. Glucose/ Uric Acid/ Total Cholesterol Fill up FAILED Fill up ok CHOL...
Note: • Please finish the test within 3 minutes or the meter will turn off automatically. • The meter will not turn on if you insert the wrong end or wrong side of strip. • Marked open date on new open strip vial, do not use expired strip. •...
Page 11
DO NOT test from alternate sites: • During or less than 2 hours after meal/ short-acting or rapid-acting insulin analogue/ exercise. • When you think your glucose level is low or unaware of your low blood glucose condition. • When you are examined for hypoglycemia or hyperglycemia. •...
Meter Memory Function Chapter 4 • Glucose - 360 results, capable in counting 7-, 14-, 21- and 28- days average • Total Cholesterol - 50 results • Uric Acid - 50 results The latest test result will replace the oldest when the records exceed maximum memory capacity.
Control Solution Test Chapter 5 Control solution is used to check the performance of the kit. The meter kit should be check: • When the meter and strip do not work properly. • When the test result is unusual or inconsistent. Control solution range is shown as follow: Please check your strip vial label for exact range.
Transmission Function Chapter 6 The meter provides Bluetooth transmission function. It can transmit test results to connected device wirelessly via Bluetooth. The screen show " " means Bluetooth transmission function is working. • The meter with Bluetooth 4.0 can apply to IOS, Android 2.3.3 and above. •...
Care and Maintenance Chapter 7 7.1 Storing Your Meter and Strip Meter: • Avoid bump or violent behavior. • Do not use in extremely dry environment. It may cause static discharges. • Do not use under electromagnetic radiation, ex: electrical equipment. •...
Error Message and Trouble Shooting Chapter 8 Message Cause Solution • Problem with code strip. Repeat the coding procedure (Chapter 2.3) and • Problem with test strip. insert the strip again. If the problem persists, • Insert strip improperly. please contact local distributor for service. •...
Page 17
• Test incomplete due to Follow Chapter 3.1 and repeat the test with a removing the strip during new strip. Do not remove the strip before the measuring. test is completed. • Improper code strip. Repeat the coding procedure (Chapter 2.3). If the problem persists, please contact local distributor for service.
Page 19
(not included in the standard kit package, please contact your local distributor for ordering) • BeneCheck Supreme Glucose Test Strips (BK-SG1)(with Insert) • BeneCheck Supreme Total Cholesterol Test Strips (BK-SC2)(with code card & Insert) • BeneCheck Supreme Uric Acid Test Strips (BK-SU1)(with code card & Insert) • BeneCheck III Glucose Control Solution •...
Page 20
● Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the BeneCheck Multi-Monitoring Meter, including cables specified by the manufacturer. Otherwise, degradation of the performance of this...
Page 21
FCC Statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Need help?
Do you have a question about the BeneCheck and is the answer not in the manual?
Questions and answers