1 Preliminary note This document is part of the device and contains information about the correct handling of the product� This document is intended for specialists� These specialists are people who are qualified by their training and their experience to see risks and to avoid possible hazards that may be caused during operation or maintenance of the device�...
3 Functions and features In combination with the IO-Link master the read/write head DTI430/DTI431 is used for non-contact reading and writing of RFID tags that conform to the system� The data is available as process data at the IO-Link interface�...
Such devices are for example frequency converters and switched-mode power supplies� 5.4 Mechanical design 1: Sensing face 5.5 Fixing ► Fix the device using the supplied nuts (M30)� flush (DTI430) non-flush (DTI431)
5.6 Mounting distances 5.6.1 DTI430 Operating mode Distance side (A) Distance front (B) For reading and writing ≥ 50 mm ≥ 100 mm 5.6.2 DTI431 Operating mode Distance side (A) Distance front (B) For reading and writing ≥ 120 mm...
5.7 Positioning of the ID tags 5.7.1 DTI430 ► Align the ID tag on the antenna central axis� Distance read/write head (D) ID tag Type metal plastics E80370 20 mm 20 mm E80371 25 mm 30 mm All indications apply to static read/write operations�...
► Disconnect power before connecting the unit� 6.1 Wiring ► Connect the unit to the IO-Link master via the M12 connector� > Voltage is supplied via the IO-Link master� IO-Link A selection of sockets is available on our website at: www�ifm�com...
7 Display elements DTI430 DTI431 LED green: operating voltage LED yellow: ID tag Status Description Green Operating voltage OK Operating voltage missing FLASHING SLOWLY Deactivated Yellow ON (permanently) ID tag detected ON (pulse) ID tag read/written successfully FLASHING QUICKLY Error when reading/writing on ID tag...
Use in all EU countries 12.1.3 EC declaration of conformity ifm electronic gmbh hereby declares that the DTI430 / DTI431 radio system corresponds to the directive 2014/53/EU� You can find the EC declaration of conformity on our website at: www�ifm�com�...