ALLDOS KM 254 series Operation Manual

Piston diaphragm dosing pump
Table of Contents

Advertisement

15.720039-V1.0
Piston Diaphragm
Dosing Pump
KM 254
Operation Manual
Please read the Operating and Servicing Manual completely and retain for future refe-
rence!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KM 254 series and is the answer not in the manual?

Questions and answers

Summary of Contents for ALLDOS KM 254 series

  • Page 1 Piston Diaphragm Dosing Pump KM 254 Operation Manual Please read the Operating and Servicing Manual completely and retain for future refe- rence! 15.720039-V1.0...
  • Page 2: Imprint

    ALLDOS Eichler GmbH Reetzstraße 85 • 76327 Pfinztal (Söllingen) Postfach 1160 • 76317 Pfinztal Germany Tel. ++49 (0) 72 40 61-0 / Fax. ++49 (0) 72 40 61-177 Mail: alldos.de@alldos.com Internet: www.alldos.com © 2005 by ALLDOS Eichler GmbH Subject to change. 15.720039-V1.0...
  • Page 3: Table Of Contents

    KM 254 en Content Imprint..................... 2 General ................... 6 1.1 Introduction ..................6 1.2 Information About the Product ............6 1.2.1 Pump Types ..................6 1.2.2 Pump Performance ................6 1.2.3 Accuracy ..................7 1.2.4 Admission Pressure and Counterpressure / Suction Height ..7 1.2.5 Sound Pressure Level ..............8 1.2.6 Degree of Protection ..............8 1.2.7 Mains Voltage ................8 1.2.8 Ambient and Operating Conditions ..........8...
  • Page 4 KM 254 en 4.5 Versions ..................18 4.5.1 Dosing heads: Materials and Additional Features .......18 4.5.2 Valves: Materials and Additional Features ........18 4.6 Materials ..................19 4.7 Data of contact manometer for MBS (optional) ......19 4.8 Installation Location ...............19 4.8.1 Space Required for Operation and Maintenance ......19 4.8.2 Permissible Ambient Influences ..........19 4.8.3 Underground ................20 Installation ..................
  • Page 5 KM 254 en Operating the Pump ..............34 8.1 Switching On/Off ................34 8.1.1 Switching On the Pump ...............34 8.1.2 Switching Off the Pump ...............34 8.2 Setting the dosing capacity ............34 8.2.1 Setting the dosing flow and locking the stroke adjustment button ..................34 8.3 Electrical servomotor (optional) .............34 8.4 Electronic stroke preset counter (optional) ........34...
  • Page 6: General

    ALLDOS directly for the information needed. ALLDOS Eichler GmbH Reetzstr. 85 D-76327 Pfinztal (Söllingen), Germany The ALLDOS service centre can be reached via our fax service or hotline: Fax: ++49 (0) 61-211 - Reference "Quality Service" Hotline:...
  • Page 7: Accuracy

    KM 254 en General * l/hr per dosing head; double the capacity for double pumps. Note The pump can be operated in the range between 10% and 100% of the maximum dosing capacity. 1.2.3 Accuracy Dosing flow smaller ± 1 % fluctuation Linearity ±1 % of the full-scale value (for water with a fully deaerated...
  • Page 8: Sound Pressure Level

    KM 254 en Maximum suction height * [m] for media with a viscosity similar to water Type Suction height Singlepump Doublepump max. [m WS] 254-50 254-50/2 254-102 254-102/2 254-143 254-143/2 254-175 254-175/2 254-213 254-213/2 254-291 254-291/2 flooded suction 254-46 254-46/2 254-97 254-97/2 254-136...
  • Page 9: Dosing Medium

    KM 254 en General 1.2.9 Dosing Medium Note In the event of questions regarding the material resistance and suitability of the KM 254 for specific dosing media, please contact the manufacturer. The dosing medium must fulfil the following characteristics for standard version pumps: •...
  • Page 10: Warranty

    Warning Other applications or the operation of pumps in ambient and operating conditions, which are not approved, are considered improper and are not permitted. ALLDOS Eichler GmbH accepts no liability for any damage resulting from incorrect use. Warranty Warranty in accordance with our general terms of sales and delivery shall only be valid if: •...
  • Page 11: Safety

    KM 254 en Safety Safety This operation manual contains general instructions that must be observed during instal- lation, operation and maintenance of the pump. This operation manual must therefore be read by the installation engineer and the relevant qualified personnel/operators prior to installation and start-up, and must be available at the installation location of the pump at all times.
  • Page 12: Safety Instructions For The Operator / User

    Observe the points described in the initial start-up section prior to subsequent start-up. Warning Electrical connections should only be connected by qualified personnel! The pump housing must only be opened by personnel authorised by ALLDOS! Observe the manufacturer's safety instructions when handling chemicals. When working on the dosing head, connections or lines:...
  • Page 13: Safety Of The System In The Event Of A Failure In The Dosing System

    KM 254 en Safety Warning To operate a pump which has been identified as an explosion protected pump for the dosing of combustible liquids or for operation in potentially explosive opera- ting sites in accordance with guideline 94/9/EC, refer to the enclosed instruction manual “Operating an explosion protected pump”...
  • Page 14: Transport And Intermediate Storage

    Drain oil from the drive mechanism, • package pump correctly. Caution Risk of malfunction or damage to the pump! ALLDOS accepts no liability for damage caused by incorrect transportation, missing or unsuitable packaging of the pump, residual media or leaking oil! Unpacking Retain the packaging for future storage or return, or dispose of the packaging in accor- dance with local regulations.
  • Page 15: Product Description And Accessories

    KM 254 en Product Description and Accessories Product Description and Accessories General Description The KM 254 are oscillatory positive-displacement pumps with hydraulic diaphragm con- trol. The operation procedure of the dosing pump is shown in the sectional drawing. The rotational movement of the drive motor (1p) is converted via the worm gearing (2p) and eccentric (3p) into the oscillatory suction and stroke movement of the piston (6p).
  • Page 16: Combined Overpressure And Degassing Valve

    KM 254 en 1p Motor 2p Worm gearing 3p Eccentric 4p Recuperating spring (not with drive size 3) 5p Sliding plug 6p Piston M combined overpressure and degassing valve 9p Diaphragm protection valve (AMS) Q Dosing diaphragm Dosing head 3a Suction valve 3b Pressure valve Stroke adjustment button Aeration screw with oil-level gauge...
  • Page 17: Dimensional Drawing

    KM 254 en Product Description and Accessories diaphragm gap (the manometer indicates “0” when the pump is running and when it is stopped). If one of these diaphragms breaks, the dosing or hydraulic medium penetrates into the intermediate gap and, when the ball is removed, into the valve. The system pressure is therefore impinged on the valve and the contact manometer is activated.
  • Page 18: Weight

    KM 254 en Weight Weight [kg] Type Dosing Head Material Single / Double pump PVC, PP, PVDF KM 254 1.4571, 2.4610 Stroke volume Stroke volume [cm Type 10bar 16 bar 25 bar KM 254 31,6 — Versions 4.5.1 Dosing heads: Materials and Additional Features For all dosing heads: •...
  • Page 19: Materials

    KM 254 en Product Description and Accessories Index No. Valve Body Gasket Valve Ball Seat Description R028 PVDF Viton PTFE PTFE spring-loaded R029 PVDF PTFE PTFE PTFE spring-loaded R033 Viton Hastelloy 2.4607 spring-loaded R046 EPDM Stainless steel Stainless steel R301 Viton Stainless steel Stainless steel for abrasive media R401...
  • Page 20: Underground

    KM 254 en 4.8.3 Underground The pump must be mounted on a flat surface. 15.720039-V1.0...
  • Page 21: Installation

    KM 254 en Installation Installation Mounting Mount the pump on a console or pump foundation using 4 screws. Note Make sure that the flow runs in the opposite direction to gravity. General Information on Installation Warning Observe the specifications for the installation location and range of application described in the “General”...
  • Page 22: Installation Examples And Tips

    KM 254 en 5.2.2 Installation Examples and Tips Picture of optimal installation max. 1m 1i Dosing tank 2i Electric agitator 3i Extraction device 4i Suction pulsation damper 5i Dosing pump 6i Overflow valve 7i Pressure retention valve 8i Pulsation damper 9i Measuring glass 10i Injection unit Tank installation:...
  • Page 23 KM 254 en Installation Pressure retention valve p ≥ 2 bar With open outflow of the dosing medium or low counter- pressure: A positive pressure difference of at least 2 bar has to exist bet- ween the counterpressure at the injection point and the pres- sure of the dosing medium at the suction valve of the dosing pump.
  • Page 24 KM 254 en For suction-side installation • Depending on the pump type and line length, it may be necessary to use a suction pulsation damper (4i). Observe the “Approximate values when using pulsation dampers” auf Seite 21 and if necessary request a system-specific calculation from our calculation program.
  • Page 25: Tube/Pipe Lines

    KM 254 en Installation Tube/Pipe Lines 5.3.1 General Warning The resistance of the parts that come into contact with the media depends on the media, media temperature and operating pressure. Ensure the parts that come into contact with the media are chemically resistant to the dosing medium in operating conditions! Only use the specified line types! All lines must be free from strain! If necessary, use swept bends instead of elbows, avoid loops and buckles in the tubes! Ensure...
  • Page 26 KM 254 en 2f Dosing head, liquid heated 2f1 Hose nipple, DN10 connection Demands placed on heating liquid: • The heating liquid must not attack stainless steel. • maximum permissible pressure: p = 3 bar • maximum permissible temperature: T = 100 °C 15.720039-V1.0...
  • Page 27: Electrical Connections

    Observe the local safety regulations! The pump housing must only be opened by personnel authorised by ALLDOS! Protect the cable connections and plugs against corrosion and humidity. Only remove the protective caps from the sockets that are being used.
  • Page 28: Connecting The Power Supply Cable

    KM 254 en S Contact manometer 5s Union nut 6s Contact output T Ball check U Connection piece 2u Deaeration screw 3u O-rings 4u Connection for earthing cable 5u Union nut *2) or locking unit Connecting the Power Supply Cable Warning Disconnect the mains voltage before connecting the power supply cable! Before connecting the power supply cable, check that the mains voltage specified...
  • Page 29: Start-Up/Shutdown

    KM 254 en Start-up/Shutdown Start-up/Shutdown Safety Information Warning When dosing dangerous media, observe the corresponding safety precautions! When working on the dosing head, connections or lines: wear the necessary protective clothing (goggles, gloves)! Before removing the dosing head, valves and media lines, empty any remaining medium in the dosing head into a driptray by carefully unscrewing the suction valve.
  • Page 30: Start-Up/Subsequent Start-Up

    KM 254 35 mm; immersion depth to marking approx. 5 mm. Caution Check the oil level at least every 2 weeks and add oil if necessary. Only use original ALLDOS gear oil! Pump Type Order No. Description KM 254...
  • Page 31: Setting The Pressure Relief Valve

    KM 254 en Start-up/Shutdown Setting the pressure relief valve If the written agreement does not specify a system-specific opening pressure, then the pressure relief valve is set to a slightly greater opening pressure than the bleed pressure for the pump. It can however be set by the customer to a smaller opening pressure. Opening pressure of the pressure relief valve Bleed pressure of Opening pressure of the...
  • Page 32: Adjusting The Zero Point

    KM 254 en from this value, adjusting the zero point will ensure that the values are more precise. Counterpressure for zero point setting of the pump at the factory Bleed pressure of Counterpressure for zero point setting the pump [bar] of the pump at the factory [bar] 7.4.2 Adjusting the Zero Point...
  • Page 33: Shutdown

    KM 254 en Start-up/Shutdown Shutdown Warning When working on the dosing head, connections or lines: Risk of injuries! Wear the necessary protective clothing (goggles, gloves)! Do not allow any chemicals to leak from the pump. Collect and dispose of all che- micals correctly! Note If possible, rinse the dosing head before shutting down the pump, e.g.
  • Page 34: Operating The Pump

    KM 254 en Operating the Pump Switching On/Off Caution Before switching on the pump, check that it is installed correctly. See the “Installa- tion” and “Start-Up” sections. 8.1.1 Switching On the Pump • Switch on the mains voltage 8.1.2 Switching Off the Pump •...
  • Page 35 KM 254 en Operating the Pump controller. V1.0...
  • Page 36: Maintenance

    KM 254 en Maintenance General Notes Warning When dosing dangerous media, observe the corresponding safety precautions! When working on the dosing head, connections or lines: Wear the necessary pro- tective clothing (goggles, gloves)! Do not open the pump! Repairs must only be carried out by authorised and qualified personnel! Switch off the pump and disconnect it from the mains before carrying out mainte- nance work and repairs! Before removing the dosing head, valves and media lines, empty any remaining...
  • Page 37: Checking The Oil Level

    KM 254 en Maintenance Clean the valves. • At least every 12 months or after 4000 operating hours, or • if the pump isn’t performing, or • in the event of an error. Clean the valves and replace if necessary (for stainless steel valves: inner parts of valve) Change diaphragms and gear oil.
  • Page 38 KM 254 en DN 20 valve stainless steel/ plastic, optional spring-loaded Caution The O-rings must be correctly placed in the specified groove. Observe flow direction (arrow)! Tighten plastic valves by hand only. Risk of damage! 15.720039-V1.0...
  • Page 39: Changing The Diaphragm And Gear Oil For Dosing Head With Single Diaphragm (No Mbs)

    Before removing the dosing head, valves and media lines, empty any remaining medium in the dosing head into a driptray by carefully unscrewing the suction valve. Caution Only use original ALLDOS gear oil! ALLDOS gear oil Pump Type Order No.
  • Page 40: Fitting The Dosing Head

    KM 254 en 1q Dosing head screw 2q Intermediate disk Dosing head Diaphragm 9.6.4 Fitting the dosing head • Fit the dosing head and tighten the dosing head screws (1q with 2q) crosswise using a torque wrench. Note Refer to the “Start-up” section for subsequent start-up! 9.6.5 Filling gear oil Caution...
  • Page 41: Replacing The Diaphragm For Dosing Head With Double Diaphragm

    KM 254 en Maintenance Replacing the diaphragm for dosing head with double diaphragm 9.7.1 Removing the dosing head 1. Close dosing lines on suction and pressure side and loosen suction and pressure valve connections. 2. Loosen the 6 dosing head screws (1q with 2q) and remove the dosing head (2). 9.7.2 Replace the double diaphragm.
  • Page 42: Fitting The Dosing Head

    KM 254 en Contact manometer (installation position) Q1 Diaphragm on dosing head side Q2 Diaphragm on oil side/pump side 3q Intermediate disk 4q Sealing rings 5q Covering rings 6q Clamping sleeves Caution The paraffin oil between the diaphragms (Q) is connected via the clamping sleeves (6q) to the contact manometer (S) in order to fill and activate the diaphragm brea- kage signal.
  • Page 43: Filling Gear Oil

    KM 254 en Maintenance 6. Only close the deaeration screw (2u) when the separating agent stops flowing. (after approx. 5 - 10 min) Note Once filled with separating agent and after a few operating hours, especially if the pressure of the manometer is increasing, deaerate again. Filling quantity of paraffin oil for dosing pumps with a double diaphragm (per dosing head) Pump Type Filling quantity in ml...
  • Page 44 KM 254 en Contact manometer 5s Union nut 6s Contact output Ball check Connection piece 2u Deaeration screw 3u O-rings 4u Connection for earthing cable 5u Union nut *2) or locking unit Removing the ball check and contact manometer 1. For pumps and manometers in flameproof version, unscrew the earthing (4u). 2.
  • Page 45: 10 Possible Errors

    KM 254 en Possible Errors 10 Possible Errors Caution Actions that are taken to overcome faults on the pump and which are not described in the operation manual, must only be carried out by the service centre! Fault Diagnosis Cause Remedy No motor sound or vibrations, Connect at power supply,...
  • Page 46 KM 254 en Fault Diagnosis Cause Remedy Suction valve: during the pressure stroke the dosing liquid flows back into the suction line. Suction/pressure valves dirty Pressure valve: during the suction Clean or exchange valves. or leaky. stroke, the dosing liquid flows back into the dosing head;...
  • Page 47: 11 Spare Parts

    KM 254 en Spare Parts 11 Spare Parts Manufacturer recommendation We recommend that you keep some spare parts in stock to ensure that worn parts can be replaced quickly when necessary. Two spare parts are required for double pumps. Permissible -10 °C to +50 °C storage temperature Permissible...
  • Page 48 10,00 bar DN 20 Stainless steel PTFE EPDM Diaphragm breakage 553-407 — 2) safety device 2) Spare parts set only for replacing diaphragm (e.g. following diaphragm breakage) without valve parts. ALLDOS gear oil Pump type Order No. Description KM 254 single 555-302 3,5 l DHG 68...
  • Page 49: 12 Dosing Curves

    KM 254 en Dosing Curves 12 Dosing Curves The dosing curves refer to: • The dosing medium water, • Zero point of pump Q for specified pressure - see diagram. Q Dosing flow Zeropoint of the pump Stroke length 254-102 (50Hz) Q = 3bar 254-102 (60Hz) Q = 3bar...
  • Page 50 KM 254 en 254-213 (50Hz) Q = 3bar 254-213 (60Hz) Q = 3bar Q [l/h] Q [l/h] 3bar 3bar 10bar 10bar 10 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100 h [%] h [%] 254-291 (50Hz) Q...
  • Page 51 KM 254 en Dosing Curves 254-166 (50Hz) Q = 10bar 254-166 (60Hz) Q = 10bar Q [l/h] Q [l/h] 10bar 10bar 16bar 16bar h [%] h [%] 254-202 (50Hz) Q = 10bar 254-202 (60Hz) Q = 10bar Q [l/h] Q [l/h] 10bar 10bar 16bar...
  • Page 52: Ec Declaration Of Conformity (Translation)

    Piston Diaphragm Dosing Pumps KM 254 has been developed, constructed and manufactured in compliance with EC directives 98/37/EC and 89/336/EEC at the sole responsibility of ALLDOS Eichler GmbH Reetzstr. 85 D-76327 Pfinztal (Söllingen), Germany The following harmonized standards have been applied: •...

Table of Contents