Kaba Mauer 71111 President A Mounting Instructions

Advertisement

Quick Links

Mounting instructions 71111 President A – 71113 President
1. General Information
These mounting instructions are the basis for the approval by ECBS, VdS, A2P (CNPP)- DNV, UL. Installation of the
lock to be performed exclusively in accordance with these instructions.
Guidelines of the national certification bodies are to be considered and complied with in addition.
Attention: The lock bolt of version 71113 with option "Not Key Retained" (Optioncode SAB) is not arrested in
position "lock open".
Any variation of the lock or key may result in functional trouble and must better not be done. All claims under guarantee
and warranty will expire in this case.
Prevent the ingress of dirt into the lock.
Lock fastening: Use of M6 steel socket head cap screws or BSW ¼" steel bolts. The length of engagement must
correspond to the applicable standards considering the thickness of the lock of 22 mm.
Fastening screws: minimum property class 4.8 and maximum property class 8.8.
Screws to be secured either by lock washer, flat spring, tooth lock washer, fan type lock washer considering the diameter
(d1) or to be cemented.
Screw tightening moment: minimum 5 Nm and maximum 6 Nm.
The bolt must be floating in installed condition.
It is recommended, that unauthorized persons have no access to security sensitive parts of the lock, also the door of the
safe, where the lock is installed, is open.
Perfect function of the lock and of any additional connected or triggered systems (e.g. boltworks) must be warranted and
checked by specialists during installation of the lock.
2. Mounting Position
RH version (standard version):
Bolt left, keyhole horizontal
Bolt downwards, keyhole vertical
Bolt upwards, keyhole vertical
3. Specification Key Guide and Key Hole
Use of the Kaba Mauer key guide (see Fig. 1) or of the Kaba Mauer key carrier guide (see Fig. 2) is recommended.
Considering DIN 2768-mH, the keyhole in the door of the secure storage unit should be dimensioned accordingly (see
Fig. 1 or 2).
Fig. 1: Key guide 86101
Lock mounting position
25,5
1 2,75
LH version (special version for LH applications):
Bolt right, keyhole horizontal
Bolt downwards, keyhole vertical
Bolt upwards, keyhole vertical
4,6
4,6
Fig. 2: Key carrier guide 86102
Revision level 11.02.2016
Page 1 of 3

Advertisement

loading

Summary of Contents for Kaba Mauer 71111 President A

  • Page 1  Use of the Kaba Mauer key guide (see Fig. 1) or of the Kaba Mauer key carrier guide (see Fig. 2) is recommended. Considering DIN 2768-mH, the keyhole in the door of the secure storage unit should be dimensioned accordingly (see Fig.
  • Page 2  In cases where the Kaba Mauer key guide or key carrier guide are not used, the maximum cross sectional area of the keyhole in the door of the secure storage unit and/or the lock armour plating may not exceed the dimensions given in Fig.
  • Page 3 Mounting instructions 71111 President A – 71113 President 5. Technical Data  Lift height of bolt 12 mm  Bolt in fully extended position: approx. 14 mm  Bolt width: 25,4 mm; Bolt height: 12,6 mm  The maximum allowable force acting on the key bolt against the blocking direction, the maximum locking force and the lateral load acting on the bolt, correspond to 1 KN and should not exceed this value.

This manual is also suitable for:

71113 president