microSYST miface PB User Manual

Universal interface profibus dp / serial interface rs232/485/422

Advertisement

Quick Links

miface PB
Universal Interface Profibus DP / Serial Interface RS232/485/422
User's Manual
microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden
Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the miface PB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for microSYST miface PB

  • Page 1 PB Universal Interface Profibus DP / Serial Interface RS232/485/422 User’s Manual microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 2: Table Of Contents

    Receive Data Frame (Serial Interface -> DP Input) CONNECTOR PIN ASSIGNMENTS LEDs Connectors Settings APPENDIX Warranty / Liability Declaration of Conformity Versions Overview Page 2 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 3: General

    Mounting: to 35 mm DIN top hat rail Protection: Front panel: IP 00 Operating temperature: 0…+50 °C Storage temperature: -25…+60 °C Page 3 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 4: Profibus Dp Interface

    187.5 kBaud / 500 kBaud / 1.5 MBaud / 3 MBaud, 6 MBaud, 12 MBaud Protocol: Profibus DP DIN19245, part 3 Page 4 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 5: Dp Configuration Data

    However a total number of 300 bytes (input + output) may not be exceeded. Default configuration: 2x 0x3F = 32 input and 32 output bytes Page 5 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 6: Dp Diagnosis Data

    0 bytes, the maximum number is 200 bytes. Receive frames are entered into the input data. At least 3 input bytes are required if receive frames are used. Page 6 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 7: Transmit Data Frame (Dp Output -> Serial Interface)

    3. Transmit frame and wait for transmission* 4. Enter data for next frame („D“) („E“) 5. Transmit next frame and wait for transmission* Page 7 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 8: Receive Data Frame (Serial Interface -> Dp Input)

    2. Frame “Hello“ (“H“) (“e“) (“l“) (“l“) (“o“) was received 3. Frame “World“ (“W“) 41 (“o“) (“r“) (“l“) (“d“) was received Page 8 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 9: Connector Pin Assignments

    Controller is not running (hardware error) Controller is running green (RUN) temporary OFF UART communication (blinking) (frame has been sent or received) Page 9 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 10: Connectors

    See chapter „Settings“ for interface selection. Profibus DP Assignment Rx+ / Tx+ GND, electrically isolated +5V, electrically isolated Rx- / Tx- Page 10 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 11: Settings

    OFF: no Profibus bus termination DIP 10 Note: Only DP addresses 0 through 126 are allowed! Delivery setting: DP address = 3 Page 11 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 12 The interval between the individual frame bytes may not exceed this duration (otherwise this would be interpreted as the end of the frame). Mode DIP 8 Standard migan (not relevant) Page 12 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 13: Appendix

    “as is”. No guarantee claims may be made in such cases. The General Terms and Conditions of microSYST Systemelectronic GmbH in current version apply as well. Page 13 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 14: Declaration Of Conformity

    Europäische Norm EN61000-6-2:2006 Elektromagnetische 2004/108/EG EN61000-6-3:2007 Verträglichkeit (EMV) Weiden, den 23.05.2012 Harald Kilian Leiter operatives Geschäft / COO Prokurist / Authorized Signatory Page 14 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...
  • Page 15: Versions Overview

    Kreuzer, Nickl: Document created 1.10 2013-03-26 Company address, warranty 1.20 2013-10-17 Logo 1.30 2014-07-22 Operating voltage Certified per DIN ISO 9001. Page 15 microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, info@microsyst.de...

Table of Contents