Refer to the WIRING DIAGRAM for electrical SPECIFICATIONS* connection details and jumper settings. Compass: It is important to install the 32500 so it remains level during operation. Resolution: 0.5 degrees This becomes increasingly important when used at northern and Accuracy: ±2 degrees (rms)
3.2 COMPASS CALIBRATION Baud rates of 1200, 4800, 9600, 19.2K, and 38.4K baud are When the 32500 is operated for the first time, its internal compass must available. Most jumper-selected output formats force the baud rate be calibrated for local conditions. To calibrate the compass, please to a predetermined value.
Page 4
12 = 1200, 48 = 4800, 96 = 9600, while connected, your external device must also be changed in 192 = 19200, 384 = 38400 order to continue communicating with the 32500 CMD250 n INPUT TYPE (1 = PULSE/POT, 2 = VIN3/VIN4) Determines the type of wind speed and wind direction signal to use.
WIRING DIAGRAM MODEL 32500 JUMPER CONFIGURATIONS & POWER 32500-90(U) Page 5...
Page 7