Wiring Instructions for a Hardwired
Hot Water Recirculation Pump
There are two options for connecting a hardwired Recirculation Pump to
the Leak Defense System Recirculation Pump Switch.
1. Disconnect the wires that feed the pump from the power source.
Attach a plug on the wires coming from the pump and plug them
into the 110VAC outlet built into Leak Defense Recirculation Pump
Switch.
2. Remove the 110VAC outlet from the Leak Defense Recirculation
Pump Switch. Attach the wires that feed the pump to the black,
white and green wires that are connected to the 110VAC outlet. You
may have to install a cord grip on the Leak Defense Recirculation
Pump Switch box to get the wires inside the box. Be careful not to
damage the circuit board inside the box. You can then place a solid
cover over the box where the outlet was.
NOTE: The plug on the Leak Defense Recirculation Pump Switch will
have to be plugged into a 110VAC outlet or hardwired to a power source.
On the API, place a jumper between +REF and the next terminal to the right which is NO. Then the red wire from the
re-circulation pump switch goes to next terminal to the right which is COM. Black wire goes to GND or -REF.
Connecting a POLD to Your LDS-3 System
If you choose to connect our wireless POLDs (Point Of Leak Detectors)
they will easily interface with your LDS-3 system to provide monitoring
and control functions.
These small devices provide a way to pinpoint certain areas such as in
laundry rooms, toilets and near other water using appliances to provide
an immediate alarm should a leak occur.