Download Print this page

Littelfuse FHZ Series Installation Instructions

5-stud zcase fuse holder

Advertisement

Quick Links

Installation Instructions

FHZ Series 5-Stud ZCASE
Part Numbers: 0FHZ0001Z, 0FHZ0002Z & 0FHZ0005Z
Description
The 5-Stud ZCASE Fuse Holder is a configurable product
designed to do primary high current power distribution. It
uses a power input terminal usually paired with a ZCASE
shunt for the input. With a common bussed power,
configurable studs (choose M6, M8, or M10) and appropriate
ZCASE fuses a wide variety of configurations is possible. The
dust covers keep dust out of the backside of the fuse box and
the cover protects the fuses from debris.
Specifications Overview
Amperage:
Available Fuse Rating:
Accessories:
Box Dimensions:
Contact Temp:
Connections:
Color:
Web Resources
Download 2D print and technical resources at:
littelfuse.com/5studzcase
Ordering Information
PART NUMBERS
0FHZ0001Z
5-Stud Assembly with Bolts and Bus Bar
0FHZ0002Z
5-Stud Full Assembly with M10 Input
0FHZ0003Z
0FHZ0005Z
5-Stud Full Assembly with M8 Input
© 2018 Littelfuse Commercial Vehicle Products
littelfuse.com
Fuse Holder
®
400A Continuous
40- 600A
Studs, Bus Bar, Tether, Dust Cover
217mm x 96mm x 59mm
-40° to 105° C
M6, M8, and M10 Bolt
Down Connection
Black
DESCRIPTION
5-Stud Box Only for Configuration
Installation
Assemble the fuse holder in the following sequence:
1.
Open AssureLatches and remove cover. If you are using
the 0FHZ0002Z, remove the nuts and the green rubber
dust covers.
2.
Place the ZCASE fuses on the studs to match stud size
and loads. If you are using the optional dust covers
replace them in the slots all the way down allowing the
tabs to engage the fuse bodies.
• Remember when selecting fuse values the continuous
current through a fuse should be calculated as 75%
of the rated value of the fuse (200A fuse should carry
150A max continuous current).
• The total long term continuous current for all fuses
should not exceed 400A.
• Intermittent loads such as motor start, starter or
compressor should not exceed 600A for 20 seconds.
3.
Place ZCASE fuse holder into the mounting position
and mark the location on the mounting surface for the
mounting bolts. Drill four holes to accommodate the M8
Mounting hardware. Bolt the holder to the mounting
surface with four M8 bolts torqued to XXNm maximum
4.
Place an appropriate sized output cable with an a terminal
matched to the stud size on the top of the ZCASE
fuses and put on an appropriate nuts on the isolated
studs. Torque the nuts to 14Nm±2Nm for M8 studs and
16Nm±2Nm for M10 studs. Be sure to hold the wire and
terminal while applying torque to prevent twisting which
can damage the fuse element.
5.
Be sure that the output cables are routed so they
have sufficient bend radius and are not at risk of being
damaged or pinched. Lastly, make sure that all cables
are strain relieved by being supported within 18" of the
battery.
6.
Replace the cover and snap the AssureLatch latches
into place Note: the cover is designed to take a label, so
good practice is to label the fuse box so each fuse and its
loads are identified, as this makes troubleshooting later
much easier
Step by step images shown in Figure 2 on page 2.
Figure 1 - Covered Assembly
1 of 2
Rev: 082018

Advertisement

loading

Summary of Contents for Littelfuse FHZ Series

  • Page 1: Installation Instructions

    0FHZ0001Z 5-Stud Assembly with Bolts and Bus Bar 0FHZ0002Z 5-Stud Full Assembly with M10 Input 0FHZ0003Z 5-Stud Box Only for Configuration 0FHZ0005Z 5-Stud Full Assembly with M8 Input 1 of 2 © 2018 Littelfuse Commercial Vehicle Products Rev: 082018 littelfuse.com...
  • Page 2 Specifications, descriptions and illustrative material in this literature are as accurate as known at the time of publication, but are subject to changes without notice. Visit littelfuse.com for the most up-to-date technical information. 2 of 2 ©...

This manual is also suitable for:

0fhz0001z0fhz0005z0fhz0002z