CONTENTS Paragraph No. Paragraph Title Page No. Introduction General Information Purpose and Capabilities List of equipment Description of the Main Components Packaging Operation and display Operation Display Power Supply Detection Channels HF Detector – Frequency Meter Channel Wire Line Scanning Analyser Channel Infrared Radiation Detector Channel LF Differential Amplifier Channel LF Magnetic Field Detector Channel...
INTRODUCTION Before operating ST 034, please study this Manual, and keep it for further reference as a guidebook. Any information contained in this Manual may be changed without prior notice. 1 GENERAL INFORMATION 1.1 Purpose and capabilities A multifunctional detection device ST034 is intended for detecting and localization of special technical means (STM) for surreptitious information obtaining as well as identification of natural and artificial sources of information leakage.
1.2 List of equipment of ST034 Basic set Supplementary set 1 Main unit 1 SHF antenna – detector ST034.SHF 2 Wire line adapter 2 Acoustic sensor ST034.A 3 HF antenna 3 Magnetic field sensor ST1034.MF 4 Telescopic antenna 5 Probes 6 Power supply 7 Mini CD 8 Technical description and operating manual...
Page 5
When working with ST034.AWL, in order to avoid electric shock, obey the rules of electrical safety. 1.3.3 Additional Transducers 1.3.3.1 Acoustic Sensor ST 034.A The sensor incorporates an acoustic transducer (microphone) and a preamplifier. Connect to the socket for external sensors. 1.3.3.2 SHF antenna-detector "ST034.SHF"...
3 Audio monitoring indicator 4 Volume level 3 POWER SUPPLY ST 034 is powered from Li pol battery or power supply unit. Completely filled icon corresponds to full capacity of the battery, completely discolored and strikethrough image corresponds completely discharged batteries.
4 DETECTION CHANNELS ST 034 has seven detection channels. Detection Channel Channel ID on display High frequency detector/frequency meter «RF» Super high frequency detector «SHF» Wire line scanning analyser «WLA» Infrared radiation detector «IR» Low frequency differential amplifier «DWLA» Low frequency magnetic field detector «MAG»...
(power mains, telephone lines, lines of fire alarm and security alert, etc.) with voltages up to 250V (DC or AC). Connecting the ST 034 to the analyzed line makes through ST131AWL using a set of probes. There are automatic and manual choices threshold, stop the scan, select the scan direction, as well as subtraction mode panorama.
View panoramas The choice is between display on the screen the full range - Complete (0.15-15MHz) and consistent indication of the range divided into three parts - Part-(0.15-5/5-10/10-15MHz) SCAN Scanning starts: • automatically after selecting this channel and automatic determination of the threshold scan. •...
Connecting the ST 034 to the analyzed line is made through the st034.AWL using a set of probes. Switch “3” ST034.AWL must be set to "DAPL". For maximum suppression of external interference signals use the regulator 1.
select (Ampl= AUTO). Select needed band by pressing the buttons"+ / -" Selecting horizontal sweep by repeatedly pressing the button "TIME / AMPL" to appear in the upper- right corner of display the inscription "Time = XXX". Where XXX is the value of current time sweep. Select needed value by pressing the buttons "+ / -"...
5 MENU Enter the menu by pressing the button , then select items by using the buttons "+" and "-", and confirm by selection button "3". To cancel or go to the previous level , press the "1" button. Choice of channels – access to the channel selection Settings System Option...
This will make an initial assessment of the availability of sources of radio emission. Analysis of the information obtained should be done with the following information: ST 034.SHF roll off at the low limit of the frequency range of the order 17 dB per octave, so the device detects radio transmitters operating in close proximity to the microwave - and the detector with frequencies close to its frequency range is the norm.
6.3 WIRE LINE SCANNING ANALYSER CHANNEL Select suitable extensions, depending on the line, and connect them to the probes. Plug the adapter into the socket, and connect the probes to the line. Check if the probes are in proper contact with the line; two light-emitting diodes in the adapter of the scanning receiver will indicate the following: - if both LED’s are lit, the line carries AC power;...
USB drivers will be installed automatically. Press "3" button and hold it, turn the power switch to "I". Release the "3". The display «ST 034" should turn on lights and do nothing until the program is loaded. If for some reason the download operation failed, the program will offer to try again.
10 WARRANTY 10.1 The manufacturer guarantees compliance of every manufactured unit with all the requirements as per technical specifications, for the period of 12 months since the date of manufacture. 10.2 The manufacturer undertakes free of charge repairs of the instrument, its auxiliary components and accessories, up to the replacement of the instrument as a whole, should it prove defective during the aforesaid period, or its performance qualities prove to be lower than those indicated in the technical specifications.
11 CERTIFICATE OF ACCEPTANCE ST034 multifunctional detection device №_______________ meets specifications ТУ6684-03-67533935-11 and found fit for use. Release Date _________________...