GENERAL SAFETY Read this manual thoroughly before you start using the Split system air con. Store this manual, the completed warranty card, your receipt and the product packaging. The safety precautions instructions reduces the risk of fire, electric shock and injury when correctly complied to.
Page 5
GENERAL SAFETY INSTRUCTIONS (Cont.) • If you notice any unusual odors or smoke around the unit, immediately disconnect the unit from the outlet and contact the service center. Failure to do so may result in fire or electric shock. • When not using the unit for long periods of time or when you are moving the unit please ensure to disconnect the power supply from the wall socket.
REMOTE CONTROL USE • Point the remote control at the unit, then press the ON/OFF button. Press the mode button, then select your desired mode: AUTO, COOL, DRY, HEAT or FAN. • Press the SET TEMPERATURE buttons to increase or decrease the readings until your desired temperature is displayed.
OPERATIONS TURBO OPERATION Press TURBO during COOL or HEAT operation, and the air rate will be set to high. Press the TURBO button again to cancel the mode. Note: During turbo mode, air rate cannot be changed. TIMER OPERATION Setting Turn off time. Set the time for the unit to turn off 1.
Page 10
OPERATIONS (Cont.) SLEEP MODE Use this mode to reduce operation sound while sleeping. • Press the SLEEP button once and air flow sound from the indoor unit will be decreased. • Press the SLEEP button again to turn Sleep mode off. NOTE: •...
Page 11
OPERATIONS (Cont.) The air conditioner must be turned off and unplugged before any maintenance is carried out. BEFORE SEASON OPERATION 1. Check to see if there are any objects or materials blocking any air intakes or outlets of both the indoor and outdoor units. 2.
SPECIFICATIONS COOLING 6200W (6.2kW) Capacity HEATING 6300W (6.3kW) COOLING 8.3 A Max. Current Input HEATING 7.9 A COOLING 1905 W Max. Power Input HEATING 1800 W Room Size Suitability 33-38 m² Rated Voltage and Frequency 220-240V AC / 50Hz Ingress Protection OUTDOOR UNIT IP24 16 kg...
Need help?
Do you have a question about the SC-6200AU6A and is the answer not in the manual?
Questions and answers