Download Print this page

Falcon F1000 Installation

Waterfree urinal
Hide thumbs Also See for F1000:

Advertisement

Quick Links

1
F1000
RETRO-FIT INSTALLATION
WATERFREE URINAL
BEFORE STARTING INSTALLATION
• Check rough-in height to achieve 24"
USE UTILITY KNIFE TO CUT CAULK then
use a putty knife and mallet to remove the
rim height (17" rim height for ADA).
bowl. Remove hanger brackets, scrape off
• Check slope. Downhill slope, per code,
caulk, and clean the wall.
is essential because waterfree urinals
require gravity flow for drainage.
5
• Check DWV material. Suitable materials
include cast iron, PVC, ABS, and
galvanized steel.
• Never install on copper DWV due to
copper's susceptibility to corrosion .
• Shut off water supply and cap the nipple
with the ¾" chrome cap (provided).
TUBE CUTTING CHART
• Measure drain nipple depth (in inches)
to find trim length (in inches)
• 13
" or more DO NOT CUT TUBE
7 8
• 3 ¾" or less DO NOT USE TUBE
MEASURE & MARK THE ROUGH-IN is in-wall
carrier is not used. Use a 5/16" masonry bit to
drill hole, then install the hanger bracket with
OR LESS
TRIM
OR LESS
TRIM
OR LESS
TRIM
one plastic anchor and screw.
.
13 ¾" ¾"
10 ¼" 3 ¼ "
6 ¾" 7 ¾ "
13 ½
½
10
4
6 ½
7 ½
8
13 ¼
¼
9 ¾
4 ¾
6 ¼
7 ¼
13
1
9 ½
4 ½
6
8
12 ¾
9 ¼
4 ¼
5 ¾
8 ¾
12 ½
9
5
5 ½
8 ½
12 ¼
8 ¾" 5 ¾
5 ¼
8 ¼
12
2
8 ½
5 ½
5
9
11 ¾
8 ¼
5 ¼
4 ¾
9 ¾
11 ½
8
6
4 ½
9 ½
11 ¼
7 ¾
6 ¾
4 ¼
9 ¼
11
3
7 ½
6 ½
4
10
10 ¾
3 ¾
7 ¼
6 ¼
10 ½
3 ½
7
7
CUSTOMER CARE
DETERMINE THE DRAIN NIPPLE DEPTH
by measuring the distance between the back
310-209-7250
of the sanitary tee (or elbow) to the front
service@falconwaterfree.com
edge of the nipple.
CAUTION
After removing any urinal from the
drain line, it's normal for certain naturally occurring
10
but potentially hazardous sewer gases to escape
through the opening until the waterless cartridge
is installed properly into the waterless urinal. If you
need to leave an open drain line unattended after
removing the urinal from the wall, temporarily wedge paper towels or a
rag into the drain hole to reduce any outflow of sewer gases, and remove
the paper towels or rag prior to completing the urinal or cartridge
installation. Never smoke, have an open flame, or place your nose or
mouth near open drain lines or waterless urinal housings into which
a cartridge is not yet properly installed.
You also can wear a breathing
mask when removing or installing any waterless urinal or cartridge to
reduce potential exposure to any such gases.
PLACE THE SEAL INTO THE
FalconWaterfree.com
FLANGE with the ribs facing
out. Install the flange with
The information in this document is
washers and hex nuts, but
subject to change without notice.
do not tighten completely.
©2015 Falcon Waterfree Technologies,
LLC. All rights reserved.
2
2" side cutter blade
IMPORTANT: Use a drain machine to remove
build-up inside pipes. Clean up to 25 feet deep
then flush with water to remove cutting debris.
Never install on copper DWV.
6
21½
Install plastic anchor
and screw here
LEVEL THE BRACKET THEN MARK, drill and install
two additional plastic anchors and screws. If pre-
existing bearing rods
not necessary.
9
A.Find the drain nipple depth on the Tube
Cutting Chart (left). Measure and mark the
specified trim length on the insert tube at
the nearest 1/4" groove.
11
12
INSTALL THE GEAR
DRILL HOLES with 5/16"
CLAMP with screw
head at bottom, but
do not tighten.
3
A. Clean face of existing wall flange.
B. Install the brass flange with the clear inspection disc.
C. Slowly pour water into the drain.
D. Use a flashlight to check the pitch/ slope No water
should be present in the inspection disc or nipple.
E. Remove flange after inspection.
7
Install additional
screws here
A.Hang the bowl on the bracket and check tail pipe alignment,
then remove the bowl and adjust the bracket as needed.
can be used, screws are
Re-hang and re-check bowl alignment with
Tail pipe should align with center of drain line.
B
A
C
B
B. Cut the tube at the groove using a sharp
utility knife to ensure a square, flat cut.
C. Clean burrs from the cut end by using
emery paper.
13
HANG THE BOWL, inserting
tailpipe into bushing, then
masonry bit for the lower
install anchor screws with
anchor screws and insert
washers. TIGHTEN FLANGE
plastic anchors.
BOLTS AND GEAR CLAMP.
4
C
D
ADJUST DRAIN TO ACHIEVE PITCH only if
standing water is present (code requires ¼"drop
per foot of drain line for proper pitch). Seal wall
according to code.
INCORRECT
CORRECT
Not centered
Centered
A
the drain line.
D
D. Apply lubricant to the outside of the rubber bushing and
ribbed inside area.
E. Insert the tube and bushing with arrow tab at the top.
Apply lubricant to tailpipe of housing.
14
15
POUR 5
GALLONS
OF WATER
as rapidly as
CAULK THE BOWL TO THE
possible into housing
WALL if there is good flow
to ensure good flow and no
and no leaks or standing
leaks or standing water.
water.
Cut away wall
Lift drain line & brace
with mending plate
B
B. Mark anchor holes then remove
bowl without moving hanger bracket.
E
Arrow
tab UP
16
CARTRIDGE
INSTRUCTIONS
INSTALL
CARTRIDGE
per the cartridge instruction
sheet.

Advertisement

loading

Summary of Contents for Falcon F1000

  • Page 1 BOLTS AND GEAR CLAMP. leaks or standing water. water. sheet. ©2015 Falcon Waterfree Technologies, LLC. All rights reserved.
  • Page 2 BOLTS AND GEAR CLAMP. plastic anchors. CLAMP. leaks or standing water. water. sheet. ©2015 Falcon Waterfree Technologies, LLC. All rights reserved.