Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd
ePA-46B
sphygmomanometer
user manual
shenzhen belter health measurement and analysis technology co.,ltd

Advertisement

loading
Need help?

Need help?

Do you have a question about the ePA-46B and is the answer not in the manual?

Questions and answers

Summary of Contents for Belter ePA-46B

  • Page 1 Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd ePA-46B sphygmomanometer user manual shenzhen belter health measurement and analysis technology co.,ltd...
  • Page 2 Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd Thank you for purchasing the BELTER electronic sphygmomanometer This product is a sphygmomanometer which uses noninvasive method to measure human blood pressure.Please be sure to read the instructions before use.After reading, please safekeeping for inspection at any time, reference.
  • Page 3: Important Safety Notes

    Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd systems used in the home healthcare environment Medical devices – Application of usability engineering EN62366: 2008 to medical devices Council Directive 93/42/EECof 14 June 1993 MDD 93/42/EEC concerning medical devices OJ L 169 of 12 July 1993 (including Directive 2007/47/EC ) Non-invasive sphygmomanometers —Part 1:...
  • Page 4 Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd necessary This item is compliant with Medical Device Directive 93/42/EEC of June 14,1993, a directive of the European Economic community Refer to instruction manual / booklet IP22 Degree of protection against harmful ingress of particulate...
  • Page 5 Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd The user must check that the equipment functions safely and see that it is in proper working condition before being used. The manufacturer does not require such preventive inspections by other persons.
  • Page 6 Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd When arrhythmia situation occurs,the measurement value may be incorrect or can not be measured. NOTICE .Please don't make an effort to curve armband and armband windpipe .While dismantling an air tube, please take the forepart of the air tube plug to pull out .Please don't bump shot or drop the product, this may lead to the measurement...
  • Page 7 Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd environmental protection regulations. How to select the adapter and use Please choose the output voltage is DC6V, output current is 1A dedicated to medical treatment power supply adapter. Please insert the plug of the power adapter into the power adapter interface of the product.
  • Page 8 Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd NOTICE The enactment scope of year is 2000-2040.If the year attains 2040, it will return 2000 Press 【 SET 】button, set 【the month be worth 】 Press one time[MEM]button, promote 1. It can quickly change data while continuously pressing down a button Press 【SET】button, set 【date 】...
  • Page 9 Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd The use of memory function Press 【MEM 】button, the device shows user's group.Press 【SET】button again, it shows the latest diagraph result.(Press 【SET】button up to change user) During the process of reading measuring memory, When long press 【MEM 】button, all the memory value will be deleted.
  • Page 10 Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd C, fix the armband in position, as position shown in below pictures . C、fix the armband tightly. Correct diagraph posture ( ) NOTICE If you use it out of the indicated temperature and humidity range,it may not be able to achieve claimed performance requirement.
  • Page 11: Data Transfer

    Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd Even forget to turn off the power ,after about 2 minutes it will shutdown automatically . Please measure and control blood pressure at the same time every day. Measurement should be taken in quiet places ,the measured person should be in a relaxed sitting position.
  • Page 12: Function Specification

    Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd Excrescent Reason Treatment circumstance The exactitude ties up good Armband doesn't take correctly arm to take Measured result is big talks or moves arm during Keep quiet and measure deviation from normal...
  • Page 13 Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd Name Sphygmomanometer ePA-46B Model number Display mode Display mode Bluetooth Supported Bluetooth V2.0 The pressure measurement scope:0-280 Measurement scope mmHg(0-37.3 kPa) Pulse scope: 40-200 Time/minute Accuracy Pressure:±3 mm Hg Pulse accuracy :±5% Power DC6v/”AA*4”...
  • Page 14 Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd Please do not place the sphygmomanometer and arm band in high temperature, damp, full of water vapor or direct sunlight conditions. Please do not let the blood pressure cuff suffer strong shock or vibration (e.g., fell on the ground).
  • Page 15: Fcc Statement

    Shenzhen Belter Health Measurement and Analysis Technology Co.,Ltd 2012-09 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.