Waste King 500 Installation Instructions Manual page 4

Commercial disposer

Advertisement

FIG. 12 SINGLE PHASE
SOLENOID
VALVE
CLOCKWISE
WHITE WIRE
ROTATION
HOT WIRE
POWER "IN"
JUNCTION
BOX
SWITCH
BOX AND
COVER
FIG. 14 THREE PHASE
SOLENOID
VALVE
CLOCKWISE
3 PHASE
ROTATION
POWER
LINE
JUNCTION
BOX
3 POLE
SWITCH
FIG. 16 WIRING FOR THREE PHASE UNITS WITH MAGNETIC SWITCH
SWITCH START - STOP
(MOUNT NEAR UNIT)
START
STOP
SWITCH BOX ON
FRONT OF UNIT
SOLENOID-RATED
MOTOR: CONSULT CHART FOR COR-
VOLTAGE TO MATCH
RECT MAGNETIC SWITCH
LINE VOLTAGE
FIG. 17 WIRING FOR SINGLE PHASE UNITS WITH MAGNETIC SWITCH
SWITCH START - STOP
(MOUNT NEAR UNIT)
START
STOP
SWITCH BOX ON
FRONT OF UNIT
SOLENOID-RATED
MOTOR: CONSULT CHART FOR COR-
VOLTAGE TO MATCH
RECT MAGNETIC SWITCH
LINE VOLTAGE
TESTING –
IMPORTANT! Do not test or run disposer dry as this will damage the seal and void the warranty.
1. Test assembly for leaks:
2. After plumbing and electrical connections are made, turn on disposer to be sure all parts are in working order and that the disposer turntable
rotates clockwise when viewed from above. Open valve in vacuum breaker line, and using valves in plumbing assembly (Fig.7), adjust so
that water swirls around just below the rim of the cone sink. Leave valves in these positions. These combinations provide a flow of approxi-
mately 8 gallons of water per minute.
3. Replace cover, retest for leaks and turn unit off.
4. Unit is now ready for operation.
®
®
C
O
M
M
E
R
C
I
A
L
by Anaheim Manufacturing
FIG. 13 WIRING FOR SINGLE PHASE
UNITS WITH MANUAL SWITCH
L-1
L-2
L1
L2
CLOCKWISE
ROTATION
T-1
T-2
T1
T2
FIG. 15 WIRING FOR THREE PHASE
UNITS WITH MANUAL SWITCH
L1
L2
L3
L-1
L-2
L-3
CLOCKWISE
ROTATION
T1
T-1 T-2
T2
T-3
T3
ALL VOLTAGES – DO NOT USE L3 OR
T3 FOR SINGLE PHASE APPLICATION
THESE TERMINALS MAY BE
LABELED T4 OR L4
COIL RATED
VOLTAGE TO
MATCH LINE
3
2
VOLTAGE
L-3
T-3
T-2
L-2
T-1
L-1
POWER SUPPLY - FUSE PER LOCAL CODE.
THESE TERMINALS MAY BE
LABELED T4 OR L4
COIL RATED
VOLTAGE TO
MATCH LINE
3
2
VOLTAGE
T-2
L-2
T-1
L-1
POWER SUPPLY - FUSE PER LOCAL CODE.
a. where cone joins table
b. where disposer joins cone
4240 E. La Palma Avenue, Anaheim, CA 92807 • (800) 454-4423 • fax (800) 246-3245 • www.wasteking.com
POWER SUPPLY -
FUSE PER
LOCAL CODE
TURNTABLE ROTATION
AS VIEWED FROM THE TOP
MOTOR JUNCTION BOX
SOLENOID RATED VOLTAGE
TO MATCH LINE VOLTAGE
POWER SUPPLY -
FUSE PER
LOCAL CODE
TURNTABLE ROTATION
AS VIEWED FROM THE TOP
MOTOR JUNCTION BOX
SOLENOID RATED VOLTAGE
TO MATCH LINE VOLTAGE
TURNTABLE ROTA-
TION
AS VIEWED
FROM THE TOP
CLOCKWISE
ROTATION
TURNTABLE ROTA-
TION
AS VIEWED
FROM THE TOP
CLOCKWISE
ROTATION
c. all piping connections
MANUAL SWITCH
MODEL
VOLTS
WK PART NO.
110-120
500 –
1500
220-240
NOTES:
1. Motor wired at Factory for 220-240
volts except for 1/2 HP. For 110-120
volts, connect motor wires as shown
inside of motor junction box cover.
MANUAL SWITCH
MODEL
VOLTS
WK PART NO.
208-240
500 –
1500
460
NOTES:
1. Motor wired at Factory for 208-240 volts.
For 460 volts, connect motor wires as
shown inside of motor junction box cover.
2. Interchange T1 and T3 to reverse rota-
tion.
MAGNETIC SWITCH
MODEL
VOLTS
WK PART NO.
208-240
750 –
1500
460
NOTES:
1. Motor wired at Factory for 208-240 volts.
For 460 volts, connect motor wires as
shown inside of motor junction box cover.
2. Interchange T1 and T3 to reverse rotation.
3. No heaters used with magnetic switch.
MAGNETIC SWITCH
MODEL
VOLTS
WK PART NO.
110-120
500 –
1500
220-240
NOTES:
1. Motor wired at Factory for 220-240
volts except for 1/2 HP. For 110-120
volts, connect motor wires as shown
inside of motor junction box cover.
2. No heaters used with magnetic switch
d. "Swirl Spray" fittings
560P333P01
2420
2420
2416
2417
2414
2415
REV B