Do you have a question about the BF BIODISC and is the answer not in the manual?
Questions and answers
Summary of Contents for Kingspan BF BIODISC
Page 1
BG, NF & NG 3 Phase Control Panel Wiring Diagram 510006P 510007P BG, NF & NG 3 Phase Alarm Control Panel 510018P Independent Loss of Rotation Alarm BioDisc is the registered trademark of Kingspan Environmental. Issue Description Date CC841 May 2010...
Covers must be kept locked. Observe all hazard labels and take appropriate action to avoid exposure to the risks indicated. The correct ongoing maintenance is essential for the proper operation of the equipment. Kingspan offer a range of maintenance contracts, details on request.
Similarly, any information or advice given by employees or agents of Kingspan regarding the design of an installation must be verified by a qualified specialist (e.g. Civil engineering consultant).
® GL0016P-02 Installation Guidelines for BioDisc Units BF, BG, NF & NG 3.4. If discharge is to a soakaway, a porosity test should be carried out in accordance with BS 6297 to assist in assessing sub-soil drainage and designing the sub-surface irrigation system. 3.5.
® GL0016P-02 Installation Guidelines for BioDisc Units BF, BG, NF & NG GENERAL CONCRETE SPECIFICATION IN ACCORDANCE WITH BS EN 206-1 ( BS 8500-1) TYPE OF MIX (DC) DESIGN PERMITTED TYPE OF CEMENT BS 12 (OPC): BS 12 (RHPC): BS 4027 (SRPC) PERMITTED TYPE AGGREGATE...
Page 7
® GL0016P-02 Installation Guidelines for BioDisc Units BF, BG, NF & NG Inlet Pipe Control Panel Power Supply Steel Wire Armoured from house Cable supply 240V 1ph (3ph optional) to control panel - (RCD protected - Customer supply) Customer Supply Concrete, Pea Shingle or other suitable free flowing material followed by...
® GL0016P-02 Installation Guidelines for BioDisc Units BF, BG, NF & NG 5.11 Place concrete backfill to approximately 500mm depth around the unit ensuring good compaction to avoid voids. Do not use vibrating pokers. 5.12 Continue backfilling with concrete up to the level of the outlet. Keep the concrete at an even level all round the unit, compacting in layers.
If the unit has been installed with no operational power supply, then remove the motor/gearbox unit, and drive chain/belt and store them in a dry or heated environment until such time as the unit is ready for permanent operation. BioDisc is the registered trademark of Kingspan.
Page 10
® GL0016P-02 Installation Guidelines for BioDisc Units BF, BG, NF & NG...
Need help?
Do you have a question about the BF BIODISC and is the answer not in the manual?
Questions and answers