The temperature indicator is mainly used in the fields of pharmaceuticals, vaccine,
blood, food, flowers and plants, laboratories, etc. especially for the places that
require using temperature indicator of high waterproof grade in cold chain storage
and transportation.
About the indicator
1
2
3
4
Technical parameters
Temperature measuring range : -30℃ ~ 70℃
Storage range : -25℃ ~ 60℃
Temperature accuracy : -20℃~+ 40℃±0.5℃, other±1℃
Sensor : Internal NTC
Log interval : 5minutes (default)
Start delay : 1min~12hr,default setting (one min as step unit)
Power suply : internal CR2450 lithium battery
Bettery life : 2 yr at 25℃ with log interval 5 min
Protection grade : IP67
Dimensions : 77mm*46mm*12 mm(L*W*H)
Weight : about 40g
Start : press the botton for over 5 seconds
Stop : press the botton for over 5 seconds
It is recommended to store at room temperature before the temperature label is not activated.
In order to ensure the waterproof level of the indicator, please do not steep the indicator in alcohol
or oleic acid and other corrosive liquids for long time.
TI-40 LCD Temperature Indicator
Double-faced adhensive
1
tape on the back
LCD screen
2
Start & stop botton
3
Bar coade & serial No.
4
Parameter con guration
1) Before delivery, the indicator's parameters are configured.
Just press START button to start it for use.
2) Default configuration:
Start delay: 10min
Log interval: 5min
Temp H2 (high): 45℃
Alarm type: cum (cumulative)
Alarm delay: 60min
Temp H1 (high): 30℃
Alarm type: cum (cumulative)
Operation instruction
1. Press (START) botton for about five seconds, "
successfully starting.
2. If there is start delay, short press the button, "
if no start delay, then "
" will be on for 30 seconds to off.
3. When the LCD temperature indicator is on, if the current status is start delay,
you can not stop the indicator by stop (STOP) buttun. After start delay time,
press the STOP button for about 5 seconds, the "
will be off, "
" lights up, it means that the LCD temperature indicator has
stopped.when the LCD temperature indicator is stopped, it will not be possible
to turn on the indicator by pressing the start (START) button.
4. short press the button to view the LCD temperature indicator's information, such as
the maximum & minimum temperature, average teprature, alarm information, etc.
Working instruction
1. Not started state: the triangle in LCD screen is not displayed, see Figure 1
Fig 1 LCD indicator not started
2. Start delay status: the triangle in LCD screen flashes for 30 seconds and goes off, see Fig. 2
Fig 2 LCD indicator start delay
Alarm delay: 10h
Temp L1 (low): -0.5℃
Alarm type: sin (single)
Alarm delay: 60min
Temp L2 (low): -5℃
Alarm type: sin (single)
Alarm delay: 60min
" will be on, The indicator
" will flash 30 seconds to off;
" icon on the LCD screen

Advertisement

loading

Summary of Contents for Elitech TI-40

  • Page 1 User Manual TI-40 LCD Temperature Indicator Overview Parameter con guration The temperature indicator is mainly used in the fields of pharmaceuticals, vaccine, 1) Before delivery, the indicator’s parameters are configured. blood, food, flowers and plants, laboratories, etc. especially for the places that Just press START button to start it for use.
  • Page 2 User Manual TI-40 LCD Temperature Indicator 3. Working status (no alarm): the triangle in LCD screen stays on for 30 seconds and goes off L1 Alarm threshold -0.5 degree, alarm type Single (Sin), alarm delay 1 hour. Fig 3 LCD indicator Working status (no alarm) L2 Alarm threshold -0.5 degree, alarm type Single (Sin), alarm delay 1 hour.