Page 2
RF Exposure “This equipment complies with FCC radiation exposure limits set forth for an uncontrolled envi-ronment. This equipment should be installed and operated with minimum distance 20cm be-tween the radiator and your body. This transmitter must not be co-located or operating in con-junction with any other antenna or transmitter.”...
1. Summary 1.1 System summary - This product is for Smart Factory. It collects analog and digital signals and sends them to the cloud server. Users can analyze sensor data on cloud servers through WIM- X(trend, alarm, report….). Thus, the improvement of the production quality can be expected.
1.2. Device specification Specification value Remark Input Voltage USB power supply DC 5V / 1A Power Consumption 10W Under Except Sensor Operation temperature -30℃~ 75℃ Processor ARM Cortex-M3 / M4 BLE / Wifi Clock 48Mhz / 80Mhz BLE / Wifi 28kByte / 256kByte BLE / Wifi 128Kbyte / 4Mbyte...
2. Product outline 2.1 View To protect the product, you must use the cradle when using the product. Power connector (USB Micro 5pin) WFS-205BW(BLE) for setting WFS-205BW(WiFi) for communication WFS-205DS (Sensor Connectino Module) Sensor wiring connector (Plug type) Cradle that can be attached to metal 2.2 Size (unit : mm)
- LED status afer power on (Normal setting status) ① WFS-205BW (BLE, WiFi) RED LED on ② WFS-205BW (WiFi) RED LED fast blink ( 250msec ) ③ WFS-205BW (WiFi) RED LED light on ④ WFS-205BW (WiFi) BLUE ELD blink ( every 1sec )
3.3 Reset button - Reset or initialization.( Each click should be within 0.5 seconds.) > 1 click is device reset. > 2 click is device hibernation. > 3 click is device device initialization. 3.4 Sensor connector - No.1 and No.2 are default. But There are differences between sensor types.
4. Sensor wiring example 4.1 Thermocouple sensor wiring (only K-type) - Default port number is 1,2 (No.1 + No.2 –) - If not connected, the temperature is 1000℃ - You wind the sensor cable 2~3 times to the ferrite core for data reliability and electromagnetic shielding.
> Example. Current output Sensor Calex PC151HT Red:+24V, Black:Signal ) Figure 3 Current output sensor example > Example. Resistance output Sensor PT100 ), Not support 3-wire RTD, but if you want to use it, short the calibration line and use it. Figure 4 Resistance output sensor 4.3 Digital input wiring - Depends on type (NPN, PNP)
Page 11
> Example. PNP Proximity sensor (Brown : +24, Blue : GND, Black : Signal) Figure 6 PNP-sensor, Need for wiring(2-3) > Example. Dry contact (General purpose relay contact) Realy Power Figure 7 General purpose relay, Need for wiring(2-3)
5. WICON Setting 5.1 Wicon manager download Connect to “www.wim-x.com” by smartphone and download “wicon manager” (Membership required) #Note: Wi-Fi data transfer (cloud server transfer) is not performed when wicon is in configuration mode during operation.5.1 Wicon manager download. 5.2 Search device Connect the power of the product, run Wicon manager and select “WF-000000”.
5.3 Serial number Enter the serial number directly or enter it as a barcode scan. If the serial number is entered correctly, proceed to the next step. 5.4 Device information If the smartphone and the BLE module are connected, the following screen will be displayed.