Main 4/5 Schematic Diagram - Philips VR340/55 Service Manual

Table of Contents

Advertisement

Main 4/5 Schematic Diagram

CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
NOTE :
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
1-11-11
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
MODE: SP/REC
PLAY MODE
1
2
3
5.0
~
5.0
REC MODE
(2.5)
INDICATES THAT THE VOLTAGE
THE SAME VOLTAGE FOR
IS NOT CONSISTENT HERE.
BOTH PLAY & REC MODES.
"
" = SMD
1-11-12
Comparison Chart of
Models and Marks
MODEL
MARK
VR340/55
A
VR340/75
B
VR740/55
C
VR740/75
D
HE274SCM4