Sierra Monitor Corporation ProtoAir User Manual

M2m gateway

Advertisement

Quick Links

FPA-W44
FPA-W44
 
M 2 M
G a t e w a y
User's Manual   
 
 
 
 
1/ 15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProtoAir and is the answer not in the manual?

Questions and answers

Summary of Contents for Sierra Monitor Corporation ProtoAir

  • Page 1 FPA-W44 FPA-W44   M 2 M G a t e w a y User’s Manual            1/ 15...
  • Page 2 FPA-W44     Sierra Monitor Corporation    Revision History:    No.  Version  Description  Date  Initial Version   1  V1.0  2017.08.28  2  V1.1  Modify 2017.09.07 3  V2.0  Update product pictures  2018.02.12 4  V2.1  Append FCC, ISED warning 2018.03.29         2/ 15...
  • Page 3: Table Of Contents

    FPA-W44 Table of Contents  1.   Foreword  .......................... 4   1.1 Copyright Notice ........................ 4   1.2 Notes  ............................ 4   1.3 Statement .......................... 4   1.4 Disclaimer .......................... 4   1.5 Limitation of Liability/Non‐warranty .................. 5   1.6 Safety Instructions ........................ 5   1.7 Precautions .......................... 5   1.8 Safety Instructions for Power Cables and Accessories  ............... 5   2.   Overview  .......................... 7   2.1 Introduction .......................... 7   3.   FPA‐W44, FPC‐N54  Hardware Instructions  ................ 8   3.1 Product Appearance ........................ 8  ...
  • Page 4: Foreword

    Sierra Monitor Corporation reserves all rights of this manual, including the right to change the content,  form,  product  features,  and  specifications  contained  herein  at  any  time  without  prior  notice.  Please  contact Sierra Monitor Corporation for further information:      US Office: Sierra Monitor Corporation Address: 1991 Tarob Court, Milpitas CA 95035-6840, UNITED STATES Tel: +1 408 964-4447 Fax: +1 408 262-9042  ...
  • Page 5: Limitation Of Liability/Non-Warranty

    FPA-W44 the safety instructions.    1.5 Limitation of Liability/Non‐warranty  For direct or indirect damage to this device or other devices of Sierra Monitor Corporation caused by  failure of conforming to this manual or the safety instructions on device label, Sierra Monitor Corporation  assumes neither warranty nor legal liability even if the device is still under warranty.  The FPA‐W44 and FPC‐N54 should be installed, debugged and maintained by professional people.    The outside antennas are not permitted to be installed or to be changed by non‐professional people. To  run  the  device  normally,  only  specify  antennas  are  approved  to  be  assembled  together  by  professional  people.  Unit shall be used with indoor‐use antenna only. No antenna for this unit can be installed outdoor.  1.6 Safety Instructions   Keep and comply with all operation instructions, warnings, and information.     Pay attention to warnings on this device.   Read  the  following  precautions  so  as  to  decrease  the  danger  of  injury,  electric  shock,  fire,  or  any  damage to the device. ...
  • Page 6 FPA-W44 removed  and  therefore  should  not  be  short‐circuited  during  transportation  or  placed  under  high  temperature.      Place cables properly:  Do not place cables at any place with extrusion danger.      Cleaning Instructions   Please power off before cleaning the device.   Do not use spray detergent.     Clean with a damp cloth.   Do not try cleaning exposed electronic components unless with a dust collector.     Support  for  special  fault:  Power  off  and  contact  technical  support  personnel  of  Sierra  Monitor  Corporation in case of the following faults: ...
  • Page 7: Overview

    FPA-W44 2. Overview  2.1 Introduction  Thank  you  for  choosing  Sierra  Monitor  Corporation.  It  is  our  commitment  to  provide  our  valued  customers  with  the  embedded  devices  equipped  with  the  state‐of‐the‐art  technology  and  the  best  product services.    Sierra  Monitor  Corporation’s  M2M  products  are  based  on  the  most  advanced  ARM  and  Intel  Atom  processors ...
  • Page 8: Product Appearance

    FPA-W44 3. FPA‐W44,  Hardware Instructions  3.1 Product Appearance      Front Side View        Right Side View  Left Side View 8/ 15...
  • Page 9: Interface Description

    FPA-W44 3.2 Interface Description    3.2.1 Power Interface  PIN1 Power connector outlook  Description Pin  Power input range DC9‐36V or AC24V L  1  DC Ground or AC24V N  2  Shell ground  3    3.2.2 Ethernet Interface  Standard RJ45 interface, supporting 10M/100M Full/Half Duplex, this is a standard RJ45 Ethernet port  Pin  Description  Remarks  1  ETH_TX+  O  2  ETH_TX‐  O  3  ETH_RX+  I  4  ETH_RX‐  I  5  ETH_CT    6  ETH_CT    7  NC   ...
  • Page 10: Rs232 Or Rs485 Connector

    FPA-W44   3.2.3 RS232 or RS485 Connector  Standard vertical 1x3x3.81mm male Terminal Block     Pin  Description  Remarks  1  TXD1 or RS485_A  IO  2  RXD1 or RS485_B  IO  3  GND    DIP Switch for select Bit  Description  Single  1  ON: have matched resistance of 120 ohm  Term  OFF: have no  2  ON: have pull up resister of 510 ohm  Bias‐  OFF: have no  3  ON: have pull down resister of 510 ohm  Bias+  OFF: have no  4  ON: select RS232  Select RS232 or  OFF: select RS485 ...
  • Page 11: Boot Configuration

    FPA-W44 DIP Switch for select Bit  Description  Single  1  ON: have matched resistance of 120 ohm  Term  OFF: have no  2  ON: have pull up resister of 510 ohm  Bias‐  OFF: have no  3  ON: have pull down resister of 510 ohm  Bias+  OFF: have no    3.2.5 Boot Configuration  Boot Configuration Boot from NAND  SHORT: OPEN: Boot from SD/MMC   3.2.6 LED    PWR LED: lighting indicate system power Okay(main power up); OFF indicate system power turn off ErrLED: User can define it.
  • Page 12: Debug

    FPA-W44   3.2.7 DEBUG  CONN,  Pin  header,  1x4x2.0,  TH,  User  can  show  the  debug  message  and  use  keyboard  input  debug  command. It’s TTL level, we need a Uart‐debug board when we use it.  PIN1 Description Pin  1  3.3V 2  TTL_TXD 3  TTL_RXD 4  DGND   3.2.8 Renew button  Renew button: long press this button will restore the factory setting, the long press time can be setting by user  ...
  • Page 13: Tips

    FPA-W44 4. Tips  Waste Disposal  It is recommended to disassemble the device before abandoning it in conformity with local regulations.  Please ensure that the abandoned batteries are disposed according to local regulations on waste disposal.  Do  not  throw  batteries  into  fire  (explosive)  or  put  in  common  waste  canister.  Products  or  product  packages  with  the  sign  of  “explosive”  should  not  be  disposed  like  household  waste  but  delivered  to  specialized  electrical&electronic  waste  recycling/disposal  center.  Proper  disposal  of  this  sort  of  waste  helps ...
  • Page 14 FPA-W44     This device may not cause harmful interference.  This  device  must  accept  any  interference  received,  including  interference  that  may  cause  undesired  operation.    Note: This equipment has been tested and found to comply with the limits for a Class B digital device,  pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against  harmful  interference  in  a  residential  installation.  This  equipment  generates,  uses  and  can  radiate  radio  frequency energy and, if not installed and used in accordance with the instructions, may cause harmful  interference to radio communications. However, there is no guarantee that interference will not occur in  a particular installation. If this equipment does cause harmful interference to radio or television reception,  which can be determined by turning the equipment off and on, the user is encouraged to try to correct  the interference by one or more of the following measures:  —Reorient or relocate the receiving antenna. ...
  • Page 15 SMA sockets is female. The manufacturer of the models is Sierra Monitor Corporation. The device must be professionally installed. Antennas to the devices can be swapped but the antenna must be provided by the manufacturer Sierra Monitor Corporation, for ensuring that the proper antennas are employed.

This manual is also suitable for:

Fpa-w44

Table of Contents