Thermostat Digital TH26
LCD Digital Thermostat can work in Manual mode
or Energy-saving mode. It can be used in electric
heating control system.
Model
Current
Description
Control and limit
TH26
16A
by double sensors
Parameter
Voltage 230V
:
Consumption:<1W
Temperature control range:5-90
℃
Temperature limitation range:16-60
℃
Temperature switch deviation:Default 1
℃
(0.5-10 ℃ adjustable )
Ambient temperature:0-50
℃
Protection class:IP20
Load capacity:16A
Connecting Cable:RVV0.5
Housing material:Anti-flame PC
1-8
The display interface and user settings
Time period mode
menred
Time period
Anti-freeze function
Mon~Sun
1 2 3 4 5
6 7
Decrease button
Menu button
1 Switch on and off
.
Press button
.
2 Temperature setting
.
Press
button
to set temperature.
3 Clock setting
.
Press
button
and
together for 5s to enter clock setting
mode. Press
button
to switch parameter and press
button
to revise.
4 Manual / Time period mode selection
.
Press
button
to switch between Manual mode and Time
period mode
.
5
.Button
lock
Press
button
together for 5s to lock or unlock the
buttons.
2-8
Advanced Settings
These settings are
for professional technical personnel.Usually
finished at the initial installation.Press
when the thermostat is switched off,and then switch on the
Manual mode
thermostat to enter Advanced Settings. Press
menu. Press
button
to exit current operating mode.
Heating
No .
Symbol
Function
Button lock
Temperature
1
Increase button
calibration
IN: built-in sensor
ON/OFF button
OUT: floor sensor
2
Sensor mode
ALL: controlled by built-in sensor
and limited by floor sensor (Default)
Floor limit
3
temperature setting
4
Switch deviation
Anti-freeze function
5
Set the upper
6
temperature limit
Rest day selection
7
and shut off Weekly
program
ON:
Thermostat status
8
OFF: thermostat stays in the same
when power on
Restore to
9
Press button
factory settings
3-8
Operating mode description
Manual Mode
Thermostat works according to the manual set temperature.
button
together
Not controlled by program.
Period Mode
button
to switch
Weekly recycle. You can set 4 time periods and corresponding
temperature every day for auto operation.
Time period, temperature, rest days can be programmed upon
the customers' request.
Adjust by
button
or
Temporary Mode
Thermostat is temporarily switched to manual mode from
Temperature adjustment
current time period mode.
Thermostat will automatically restore to time period mode
when the next time period comes.
Sensor malfunction
It means the internal sensor malfunction
16~60 ℃.Default 45 ℃
Period programming
Hold key
for at least 5s to enter period programming
0.5~10 ℃.Default 1.0 ℃
Default OFF
Time
The setting range is
Option
after activation
5~10 ℃
Period
Set range
16~90 ℃
.
1
Default 35 .0℃
5(rest on Sat and Sun. Default)
2
6 rest on Sun
(
)
7
(
no rest day
)
3
OFF
(shut off Weekly program)
thermostat is in off mode
4
mode before power off (Default)
1
until --- is displayed
2
when ER0 appears.
Default
Default
Symbol
Time
Temp.
06 : 00
20℃
08 : 00
15℃
17 : 00
22℃
22 : 00
15℃
22℃
08 : 00
23 : 00
15℃
4-8
Need help?
Do you have a question about the TH26 and is the answer not in the manual?
Questions and answers