Table of Contents

Advertisement

Available languages

Available languages

Quick Links

ZoneScan II
Field Installation Instructions
Y63158-TUM
Revision A
www.Aclara.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZoneScan II and is the answer not in the manual?

Questions and answers

Summary of Contents for Aclara ZoneScan II

  • Page 1 ZoneScan II Field Installation Instructions Y63158-TUM Revision A www.Aclara.com...
  • Page 2: Proprietary Notice

    Disclaimer The information in this document is subject to change without notice and should not be construed as a commitment by Aclara. Aclara assumes no responsibility for any errors that may appear in this document. No responsibility is assumed for the use or reliability of software on equipment that is not supplied by Aclara.
  • Page 3: Warnings, Cautions, And Notes

    • Consult the dealer or an experienced radio/TV technician for help. Any changes or modification made to this device without the expressed, written approval of Aclara Technologies LLC may void the user's authority to operate this device. ZoneScan II Field Installation Instructions...
  • Page 4: Field Calibration Procedure

    Antennas Only the antenna provided with this meter is authorized to be used without approval from Aclara, the FCC, and ISED. FCC/IC RF Exposure Guide Aclara Technologies LLC low power RF devices and their antennas must be fixed-mounted on indoor or outdoor permanent structure(s) providing a separation distance of at least 20 cm from all persons during normal operation.
  • Page 5 • Consulter le fournisseur ou un technicien radio ou télévision expérimenté. Tout changement ou toute modification à cet appareil sans l'approbation écrite expresse d'Aclara Technologies LLC peut annuler l'autorisation de l'utilisateur d'utiliser cet appareil. ZoneScan II Field Installation Instructions...
  • Page 6 RF. Procédure de calibration sur place Les appareils RF à faible puissance Aclara Technologies LLC ont été soumis à des tests étendus et multi-tâches et à des procédures de calibration complexes en usine. Par conséquent, ils ne requièrent pas de calibration ni d'ajustement supplémentaire sur place.
  • Page 7 ZoneScan Technical Manual (Y20284-TUM) The technical manual provides information about acoustic leak detection and monitoring ZoneScan data. Commissioning Document (obtain document from Ralph W.) If, at any time, you would like to speak with a Aclara representative about any product or service, please contact Support at support@aclara.com or by calling 1-800-892-9008.
  • Page 8 Identification ZoneScan 820 Sensor Transmission Unit Communication Cable 7 ¼” Non-Metallic Valve Lid / Antenna Assembly Completed Assembly 6-foot Lanyard ZoneScan II Field Installation Instructions P a g e...
  • Page 9: Tools/Equipment Required

    Tools/Equipment Required Magnet C. Unpack ZoneScan II Transmission Unit and ZoneScan Sensor, Communication Torque Wrench (break over at 5-inch Cable and 6’ Lanyard pounds) Measuring Tape (10-feet minimum) Flashlight Appropriate personal protective equipment (PPE) Deployment of the ZoneScan II System is typically performed in the road.
  • Page 10 Transmission Unit (with confirm commissioning was successful. extension if necessary) to the loop on the N. Carry the fully assembled ZoneScan II ZoneScan 820 Sensor. Unit to the valve stack O. Place the ZoneScan 820 Sensor into the...
  • Page 11 (a slow flashing red light on LEDs). To redeploy the ZoneScan II Unit, proceed to Step M above. Repackaging To repackage the unit: Disconnect yellow Gutermann cable from logger and MTU. Disconnect carabiner from 6-foot lanyard.

Table of Contents