Galaxy Configuration Guide
for Morpho
SIGMA Readers
®
Compatible with Galaxy Hardware
JAN 2019 | SG 11.1.0.2
Galaxy supports Legacy Mode in SG 10.3.1 or higher
Page 1 of 9

Advertisement

Table of Contents
loading

Summary of Contents for Sagem Morpho SIGMA

  • Page 1 Galaxy Configuration Guide for Morpho SIGMA Readers ® Compatible with Galaxy Hardware JAN 2019 | SG 11.1.0.2 Galaxy supports Legacy Mode in SG 10.3.1 or higher Page 1 of 9...
  • Page 2 System Galaxy Version 11.x How to Install THIS MANUAL IS INITIALLY DISTRIBUTED STARTING WITH THE 10.4 RELEASE OF SYSTEM GALAXY SOFTWARE. HOWEVER MA-SIGMA READERS ARE COMPATIBLE WITH and Configure NEW AND EXISTING INSTALLATIONS. Information in this document is subject to change without notice. MorphoAccess ®...
  • Page 3: Table Of Contents

    Wiring the MA SIGMA Reader at Galaxy Controllers..............6 Diagram of MA SIGMA Reader with back open ........................6 About Sagem’s Installation Quick Guide ..............7 Programming the SIGMA Reader ..................... 8 Creating/Loading Bases & Setting Reader Recognition Modes ........... 9...
  • Page 4: Introduction To Sagem Morphoaccess ® Sigma Readers

    SIGMA Readers ® The Sagem MA Sigma reader is a new generation of Sagem biometric reader. Galaxy currently supports the MA Sigma reader in Legacy mode for new and existing installations of System Galaxy 10.3.1 or higher. NOTE: MA-SIGMA is compatible with preexisting installations of Sagem Morpho readers by using the Legacy Morpho mode.
  • Page 5: Requirements & Cautions

    2. Input power is rated at +12V / 1A ( according to the markings on the reader – i.e. orange warning sticker 3. The Sagem install guide recommends using 20-24 AWG non-stranded wiring for the data and power input. Galaxy recommends using shielded cable for data connections.
  • Page 6: Installing And Configuring Ma-Sigma Readers

    Installing and Configuring MA-SIGMA Readers Wiring the MA SIGMA Reader at Galaxy Controllers The SIGMA reader supports the reader wiring and is compatible with the 600/635 DRM Board. The Sagem install guide recommends 20-24AWG, non-stranded wiring. Galaxy recommends 22 AWG shielded cable.
  • Page 7: About Sagem's Installation Quick Guide

    About Sagem’s Installation Quick Guide The MA SIGMA reader comes with a pictogram (no words) install cheat sheet. It has each step depicted in diagrams with no words. On the front page (top right corner) is the pin-out diagram of the Sigma reader as viewed from the back with the reader turned upside down.
  • Page 8: Programming The Sigma Reader

    Programming the SIGMA Reader The Sigma reader programming is basically the same as the 500-series in that you can manually edit the biometric control settings, network parameters, card formatting, etc. 1. Power ON the reader. The ‘Boot Assistant’ app will launch automatically. 2.
  • Page 9: Creating/Loading Bases & Setting Reader Recognition Modes

    Galaxy SG Sagem Guides for the appropriate reader (MA 110 or 520). 7. Load Finger/card data: The GCS Sagem Loader Utility supports loading fingers. Use the main screen of the Loader to clear bases, load finger, and get configuration from the reader.