Download Print this page

B+B HYT939 Operation Manual

Digital humidity-temperature module with i2c-interface

Advertisement

Quick Links

OPERATION MANUAL
Digital Humidity-Temperature Module HYT939
with I²C-Interface
Description
Description
Technical data
Humidity measurement
Measuring range humidity
Accuracy humidity
Reproducibility
Hysteresis
Resolution Humidity
Linearity
Tk residual error (50 % RH)
Long-term drift
Meassuring principle
Temperature measurement
Measuring range temperature
Accuracy temperature
Reproducibility
Resolution Temperature
Long-term drift
Meassuring principle
General
Dimensions (∅ x H)
Operating voltage
Current consumption
(nominal)
Current consumption (max.)
Power consumption (sleep)
Operating temperature
Humidity range
Digital interface
Material
Water absorption
Connection
Storage temperature
CE-conformance
Electromagnetic conductivity
Environmental data
Technical changes reserved
0141 0316-198 16.06.2016
0 ... 100 % RH
± 1,8 % RH at +23 °C
(0 % RH to 90 % RH)
0 .. 10 % RH (0 ... 50 ° C)
± 0,2 % RH
<± 1 % RH
0,02 % RH
< ± 1 % RH
0,05 % RH / K (0 ... 60 °C)
< 0,5 % RH / a
Capacitive polymer humidity sensor
- 40 ... +125 °C
± 0,2 K (0 °C to +60 °C)
± 0,1 K
0,015 °C
< 0,05 K / a
PTAT (integrated)
13 mm x 32 mm
2,7 ... 5,5 V
< 22 µA at 1 Hz update rate
850 µA
< 1 µA
-40 °C ... 125 °C
0 ... 100 % RH
I2C, s. Art. No. page 2
Polyamid, black
3...4%
Binder plug 5 ways Series 711
-20°C...+50°C
2014/30/EU
EN 61326-1:2013
RoHS-complient
B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen
Fon +49 771 83160 | Fax +49 771 831650 | info@bb-sensors.com | bb-sensors.com
Features
• Dew resistant
• Temperature compensated
• I²C interface
• Low hysteresis
• Compensated linearity error
• Low temperature drift
• Easily replaceable
Applications
• Mechanical engineering
• Environment technology
• Plant engineering
• Medical devices engineering
• Dryer systems
• Building automation
• in connection with internal bus systems
Description
Accurately calibrated, digital humidity-temperature module with I²C
interface. The sensor is dew resistant, temperature compensated,
shows a very low hyteresis, negligible long term drift and linearity
errors. Up to 112 addresses on the same bus line. It is mechanically
robust, easy exchangeable and chemically resistant. The module
features a high quality micro system on ceramic substrate using a
polymer capacitive humidity sensor. The TO-39 housing with steel
mesh filter is suitable among others for the use in medical devices and
dryer systems.
Attention
Please avoid extreme mechanical and inappropriate exposure.
The device/product is not suitable for potential explosive areas and
medical-technical applications.
1 / 2

Advertisement

loading
Need help?

Need help?

Do you have a question about the HYT939 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for B+B HYT939

  • Page 1 CE-conformance 2014/30/EU Electromagnetic conductivity EN 61326-1:2013 Environmental data RoHS-complient B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen Technical changes reserved 1 / 2 Fon +49 771 83160 | Fax +49 771 831650 | info@bb-sensors.com | bb-sensors.com 0141 0316-198 16.06.2016...
  • Page 2 You can find the detailed datasheet on our home- page: Service&Support -> Downloads -> Data sheet HYT939 B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen Technical changes reserved 2 / 2 Fon +49 771 83160 | Fax +49 771 831650 | info@bb-sensors.com | bb-sensors.com...