- Statistics on output activity temperature and supplied solar heat (Info). - Control of 1 or 2 cylinders, a 2-layer cylinder or a swimming pool. - Management and optimization of auxiliary heating (electric or hydraulic). - Heating boost, instant or daily-programmed. SR IMH ENG LH V06 19 09 2013...
Page 5
Aperçu du boîtier VERVIEW RODUCT OVERVIEW Dimensions 110 mm 45 mm 84 mm 20,5 mm 42,2 mm User interface Installer setting Installer wiring interface interface This manual describes only the installation, commissioning, operation, maintenance and dismantling of the temperature differential controller for solar thermal energy systems. When installing the remaining components, e.g.
VERVIEW OLAR SYSTEM OVERVIEW System Diagram System Description System 1 = SR This system is intended for the control of a basic solar water heater with electric auxiliary heating System 2 = SRPC This system is intended for the control of a basic solar...
Page 7
VERVIEW OLAR SYSTEM OVERVIEW System Diagram System Description SYST8 2TKV System 8 = 2TKV This system is intended for the control of a dual- cylinder solar water heater from a 3-way valve R2 : 3-way valve SYST9 2TKP System 9 = 2TKP This system is intended for the control of a dual- cylinder solar water heater from two pumps SYST10...
VERVIEW IAGRAM User interface Modes Standby, Max, Eco, Holidays, Mode key Test, Clock and Selecting the mode +/- keys Set key To change a Setting value or display parameters next parameter ok/info key Boost key To validate a Boost activation value / display next setting or display...
VERVIEW YMBOLS AND ABBREVIATIONS LEXICON Symbol Symbol Solid display Flashing display Mode selectors Solar collector T1 sensor temperature (solar collector) T1 sensor selection T2 sensor temperature (lower section of T2 sensor selection the cylinder or the pool) T3 sensor temperature T3 sensor selection T4 sensor temperature T4 sensor selection...
Page 10
VERVIEW YMBOLS AND ABBREVIATIONS LEXICON Symbol Solid display Flashing display Heat transfer to central heating (HRI Boost in progress system) Delayed start or stop of the solar pump Error Max. temperature reached Cylinder Pool Internal heat exchanger External heat exchanger Electric heater Electric heater selection...
Page 11
VERVIEW YMBOLS AND ABBREVIATIONS LEXICON Abbreviations Abbreviation Description on display Boost Boost cycle start (only daily Boost) Boost cycle duration User Mode Standby mode Clock Mode Time Low-tariff period Low-tariff period start time Low-tariff period stop time Info and statistics Supplied heat quantity estimation for the last 24 hours (KWh) or in total (MWh) R1 output on time count for the last 24 hours...
Page 12
VERVIEW YMBOLS AND ABBREVIATIONS LEXICON Select System System SRPC = Number 2 Con g mode 1 or 2 pumps (with system 12) Flat collector type Evacuated tube collector type Temperature setpoint for storage cylinder Temperature setpoint for second storage cylinder Solar pump control (R1), ON/OFF mode Solar pump control (R1), speed variation mode (RPM) Storage cylinder loading priority order...
Page 13
VERVIEW YMBOLS AND ABBREVIATIONS LEXICON Language selection Degree unit selection Display/light timeout Functions mode Anti-legionella function Anti-legionella temperature setpoint System cooling safety function Cylinder temperature safety limit Anti-Freeze function Anti-Freeze temperature limit Cold start function Cold start collector temperature limit Heat quantity estimation function Expert mode Maximum collector temperature...
Page 14
VERVIEW YMBOLS AND ABBREVIATIONS LEXICON Expert plus mode Length of the collector probe Temperature difference zero adjustment value T1 temperature zero adjustment value T2 temperature zero adjustment value T3 temperature zero adjustment value T4 temperature zero adjustment value Nominal temperature difference for pump speed control Unit temperature difference for pump speed control Minimum pump speed ratio Tube collector temperature test duration...
Page 15
VERVIEW YMBOLS AND ABBREVIATIONS LEXICON Cooling running at T1 DTCO delay running Cold start function running Pump overrun function running Warning messages AL cannot run because no auxiliary heating enabled AL Not Working properly E1 Not Working properly Errors Short-circuit at T1 preventing the system from working Open-circuit at T1 preventing the system from working Reset Restore factory settings...
OMMISSIONING AND OPERATIONS OMMISSIONING 1- Select the language. 2- Set the time. 3- Select the system. 1- Setting the language 3- Setting the time One of 10 languages may be selected: The internal off-peak hours and programmable Boost functions require the French English time to be set.
OMMISSIONING AND OPERATIONS SERS SETTINGS Setting access From Auto mode, press to access user settings. Using you can change the parameter Save it by Select the type of Boost The boost function is factory set ‘one –shot’ i.e. heating once at mode run. You can change this to a programmed ‘daily boost’, the screen shows by pressing and setting to...
OMMISSIONING AND OPERATIONS PERATING MODES Select the required mode by pressing once or several time. Mode sequence: Max Mode Eco Mode Holidays Mode Test Clock Standby Mode (automatic) (automatic) (automatic) Mode Mode Standby Mode Clock setting Mode This mode disables the water heating , in Mode to change the time and time-related summer for instance.
OMMISSIONING AND OPERATIONS EST MODE MANUAL TESTING OF THE INSTALLATION 4- You can change the output state by using 1- Press to select the Test mode. 2- Press to select the Go to the next output by pressing output you want to force for testing. 3- Press to modify the output state.
Page 20
OMMISSIONING AND OPERATIONS Time setting Internal Low-tariff period setting enable Off-peak Period start Off-peak Period end Priority between programmed off-peak times (LOWP) and off-peak times determined by the contact (E1SYNC) connected to an external clock “Ext clock”: - A time is deemed to be “off-peak” by the system: If the circuit connecting the two “Ext clock”...
OMMISSIONING AND OPERATIONS OOST FUNCTION Boost start From Auto Max mode or Auto Eco mode, Boost function is used to guarantee that the hot Boost function can be used only if you set up an electric heater or a hydraulic auxiliary heating from a boiler.
AFETY FUNCTIONS YSTEM COOLING If the system cooling function is not activated (default), the solar pump is stopped once the collector temperature (T1) reaches T1 MAX. If the System cooling function is activated (COOL ON in the « Optional function » mode), the solar pump will run as soon as the collector temperature reaches T1 MAX (set in the «...
AFETY FUNCTIONS FREEZE PROTECTION If the Anti-freeze protection (AF) function is activated, the solar circuit pump is switched on as soon as the collector temperature sinks below +4°C (adjustable limit). This causes heat to be pumped through the collector from the lower part of the storage cylinder in an attempt to prevent the collector from freezing.
OMFORT FUNCTIONS OLAR PUMP CONTROL control modes: Basic On/Off control mode (ON/OFF): the pump runs (at full speed) or not, no speed Speed control mode (RPM): this is a full-wave packet control mode for pump speed some other control settings (like the minimum speed ratio, eg 30%) may be re-set (in the « Expert plus »...
Page 25
OMFORT FUNCTIONS UXILIARY BACKUP HEATING Triggering conditions for auxiliary backup heating Auxiliary backup Mode type SYSTEM 8 Solar system SYST8 2TKV with 2 T3<T2Set cylinders, MAX+OFPP R3(ELEC) R1=OFF 3-way Valve (T4-T2)<dT and Electric auxiliary heating ECO+BOOST MAX+BOOST SYSTEM 9 Solar system with 2 SYST9 cylinders,...
Page 26
OMFORT FUNCTIONS UXILIARY BACKUP HEATING Systems 7 & 11 do not feature electric auxiliary backup heating. Triggering conditions for auxiliary backup heating Auxiliary backup type Mode SYSTEM 7 Pool solar External heat heating with exchanger External Heat (T3-T2)<dTA Exchanger SYSTEM 11 SYST11 Solar system Central...
Page 27
OMFORT FUNCTIONS UXILIARY BACKUP HEATING Triggering conditions for auxiliary backup heating Auxiliary backup Mode type SYSTEM 4 Solar system R2 (HYD) with Solar pump speed control, SYST4 HYPC HYDraulic R1=OFF and Electric auxiliary T3<T2Set heating MAX+BOOST R3 (ELEC) ECO+BOOST SYSTEM 10 R2 (HYD) Solar system with Smart...
Page 28
OMFORT FUNCTIONS UXILIARY BACKUP HEATING System 5 : Electric and Hydraulic auxiliary backup heating are independent and can operate simultaneously. Auxiliary Triggering conditions for auxiliary backup heating backup Mode type SYSTEM 5 R2 (HYD) Solar system with External Heat (T4-T2)>dT EXchanger and Electric auxiliary...
This function (only available for systems 1/3) requires an extra sensor (T4) to measure the return supply system. have to be entered at the SR controller settings (FL L/M). concentration have to be set at the controller. Heat Quantity Estimation (HQ) to be read in the INFO mode:...
YSTEM STATE AND DISPLAY YSTEM INFORMATION DISPLAY System information display From Auto mode, by pressing successively several times, the system information are scrolled through on screen. System information Display Related systems T1 temperature T2 temperature dT temperature T3 temperature T4 temperature dTA temperature = T1-T4 (if heat quantity function enabled) dTA temperature = T4-T2...
Page 31
YSTEM STATE AND DISPLAY YSTEM INFORMATION DISPLAY Note eg the system protection is currently running, it is displayed with the system information. Display Function System Protection against High temperature running at T2 AF protection running (at collector) Cooling running at T1 DTCO delay running Cold start function running Pump overrun function running...
YSTEM STATE AND DISPLAY TATISTICS Statistics display From Auto mode, press to access Statistics display. You can scroll through the statistics, using Statistics Display Related systems Heat Quantity/24H (if fonction enabled) Heat Quantity/total (if fonction enabled) R1 output on time count for the last 24 hours R1 output on time count in total R2 output on time count for the...
AFETY ADVICE ROPER USAGE The temperature differential controller may only be used for controlling solar thermal systems within the permissible ambient conditions. Statistical information displayed by the controller is only indicative. The controller must not be operated in outdoor or damp room environments. ANGERS DURING INSTALLATION AND OPERATIONS DANGER Risk of electrocution!
OUNTING ALL INSTALLATION 1- Remove the front cover. through the hole in the housing socket. Set the lower wall plug. Distance between the attachment points: 130 mm. 2- Unscrew the screw at the bottom of the product, and remove the terminal cover.
OUNTING UMP STATION INSTALLATION it is inserted in a pump station. Use self-tapping screws. NSTALLATION ON A DIN RAIL 1- Mounting 2- Unmounting Hang the controller on the upper edge of First take off the terminal cover. the DIN rail. Draw the hook towards the bottom with a Then push the controller at the bottom, the solar controller will lock automatically on...
Earth terminals of the SR controller. The installation shall comply with applicable safety regulations (including EN60730 standard) and local installation guidelines, especially the SR device is to be connected via a disconnection device i.e. a circuit breaker or a detachable external fuse.
Page 37
OWER SUPPLY AND ELECTRICAL CONNECTIONS VERVIEW Power connections Earth terminals R2 output terminals The earth brought with the power supply L = Switched output Line can be connected to the actuators (eg. N = Neutral the solar pump). Power supply terminals R3 output terminals L = Line Free-voltage output switch...
Page 38
OWER SUPPLY AND ELECTRICAL CONNECTIONS VERVIEW Signal connections T1 sensor input T4 sensor input No polarity No polarity T2 sensor input E1 synchronisation input No polarity To be connected to an external time switch T3 sensor input No polarity...
OWER SUPPLY AND ELECTRICAL CONNECTIONS USE REPLACE DANGER Risk of death by electrocution! 1- Before opening the case, remove the controller from the power supply. 2- Unfasten the screw and take off the terminal cover. 3- Remove the blown fuse from the fuse holder. 4- Remove the spare fuse from behind the terminal cover and mount it in the fuse holder.
Page 40
OWER SUPPLY AND ELECTRICAL CONNECTIONS ONNECTIONS Syst 2 Basic solar system with Solar pump speed control and ELectric auxiliary heating Syst 3 Solar system with HYDraulic and Electric auxiliary heating...
Page 41
OWER SUPPLY AND ELECTRICAL CONNECTIONS ONNECTIONS Syst 4 Solar system with Solar pump speed control, HYDraulic and Electric auxiliary heating Syst 5 Solar system with External Heat EXchanger and Electric auxiliary heating...
Page 42
OWER SUPPLY AND ELECTRICAL CONNECTIONS ONNECTIONS Syst 6 Basic POOL solar system Syst 7 Pool solar heating with External Heat Exchanger...
Page 43
OWER SUPPLY AND ELECTRICAL CONNECTIONS ONNECTIONS Syst 8 Solar system with 2 cylinders, 3-way Valve and Electric auxiliary heating Syst 9 Solar system with 2 cylinders, 2nd Pump and Electric auxiliary heating...
Page 44
OWER SUPPLY AND ELECTRICAL CONNECTIONS ONNECTIONS Syst 10 Solar system with Smart Hydraulic auxiliary heating from Solid fuel boiler and Electric auxiliary heating Syst 11 Solar system with Heating Return Increase...
Page 45
OWER SUPPLY AND ELECTRICAL CONNECTIONS ONNECTIONS Syst 12 Syst 13 Solar system with 2-Layer cylinder, 3-way Valve and Electric auxiliary heating...
NSTALLER SET ETTING ACCESS You can modify the default settings by entering one of the four Install modes : - Optional Function: to set some optional functions - Expert Setting: to set some expert parameters - Expert Setting Plus: to set some secondary expert parameters How to set the product Restoring factory settings (reset) The Reset function restores the factory...
NSTALLER SET ELECT SYSTEM 13 systems System 01 System 06 System 11 System 02 System 07 System 12 System 03 System 08 System 13 System 04 System 09 System 05 System 10...
. 01 NSTALLER SET SYSTEM : Basic solar system with Electric auxiliary heating Factory Setting Values Collector Type Cylinder temperature setpoint From Temperature difference to switch on the From solar heating Temperature difference to switch off the From solar heating R3 output Temperature difference (from the From...
Page 49
. 01 NSTALLER SET Optional function Factory Setting Values Maximum cylinder temperature (safety) From Anti-Freeze function Anti-Freeze temperature threshold From Cold start function Cold start temperature threshold From Heat Quantity Estimation function Anti-Freeze uid type Anti-freeze glycol concentration rate From Flow Rate from Meter Reading From Expert Setting...
. 01 NSTALLER SET Expert Setting Factory Setting Values Minimum pump-on duration Expert Setting Plus Factory Setting Values Collector probe length Temperature difference zero adjustment From value Additional temperature difference zero adjustment value From (if Heat Quantity function enabled) T1 temperature zero adjustment value From T2 temperature zero adjustment value From...
Page 51
. 02 NSTALLER SET Factory Setting Values Temperature difference to switch on the From solar heating Temperature difference to switch off the From solar heating R3 output Temperature difference (from the From temp. setpoint) for Auxiliary heating authorization Language Degree unit Display / light timeout (except for INSTALL) Optional function...
Page 52
. 02 NSTALLER SET Optional function Factory Setting Values Cold start function Cold start temperature threshold From Expert Setting Factory Setting Values Maximum collector temperature From Collector temperature safety limit From Night temperature setpoint (for From HOLIDAYS mode) Maximum cylinder temperature (safety) From Minimum pump-on duration Expert Setting Plus...
. 02 NSTALLER SET Expert Setting Plus Factory Setting Values Nominal temperature difference for From pump speed control Unit temperature difference for pump From speed control Minimum pump speed ratio From Collector temperature test duration (if From tube collector type) SYSTEM : Basic solar system with Hydraulic and Electric auxiliary heating...
Page 54
. 03 NSTALLER SET Factory Setting Values Degree unit Display / light timeout Optional function Factory Setting Values Anti-Legionella function Anti-Legionella temperature threshold Cooling (safety function) Maximum cylinder temperature (safety) From Anti-Freeze function Anti-Freeze temperature threshold From Cold start function Cold start temperature threshold From Heat Quantity...
Page 55
. 03 NSTALLER SET Optional function Factory Setting Values Flow Rate from Meter Reading From Expert Setting Factory Setting Values Maximum collector temperature From Collector temperature safety limit From Night temperature setpoint From (for HOLIDAYS mode) Maximum cylinder temperature (safety) From Minimum pump-on duration Expert Setting Plus...
. 03 NSTALLER SET Expert Setting Plus Factory Setting Values T4 temperature zero adjustment value From (if Heat Quantity enabled) Tube collector temperature test duration From (if TUBE type collector) SYSTEM : Solar system with Solar pump speed control, Hydraulic Auxiliary and Electric auxiliary heating Factory Setting Values Collector Type...
Page 57
. 04 NSTALLER SET Optional function Factory Setting Values Anti-Legionella function Anti-Legionella temperature threshold Cooling (safety function) Maximum cylinder temperature (safety) From Anti-Freeze function Anti-Freeze temperature threshold From Cold start function Cold start temperature threshold From Expert Setting Factory Setting Values Maximum collector temperature From...
Page 58
. 04 NSTALLER SET Expert Setting Plus Factory Setting Values Collector probe length Temperature difference zero adjustment From value T1 temperature zero adjustment value From T2 temperature zero adjustment value From T4 temperature zero adjustment value From Nominal temperature difference for From pump speed control Unit temperature difference for pump...
. 05 NSTALLER SET SYSTEM : Solar system with External Heat Exchanger and Electric auxiliary heating Factory Setting Values Collector Type Cylinder temperature setpoint From R1 output, R1 pump control, ON/OFF mode (STD) bor speed variation mode (RPM) Temperature difference to switch on the From solar heating Temperature difference to switch off the...
Page 60
. 05 NSTALLER SET Optional function Factory Setting Values Cooling (safety function) Maximum cylinder temperature (safety) From Anti-Freeze function Anti-Freeze temperature threshold From Cold start function Cold start temperature threshold From Expert Setting Factory Setting Values Maximum collector temperature From Collector temperature safety limit From Night temperature setpoint...
Page 61
. 05 NSTALLER SET Expert Setting Plus Factory Setting Values Collector probe length Temperature difference to switch on the From solar heating from the exchanger Temp. difference to switch off the solar From heating from the exchanger Temperature difference zero adjustment From value Additional temperature difference zero...
. 06 NSTALLER SET SYSTEM : Basic pool solar heating Factory Setting Values Collector Type Cylinder temperature setpoint From R1 output, R1 pump control, ON/OFF mode (STD) bor speed variation mode (RPM) Temperature difference to switch on the From solar heating Temperature difference to switch off the From solar heating...
Page 63
. 06 NSTALLER SET Optional function Factory Setting Values Cold start function Cold start temperature threshold From Expert Setting Factory Setting Values Maximum collector temperature From Collector temperature safety limit From Night temperature setpoint From (for HOLIDAYS mode) Minimum pump-on duration Expert Setting Plus Factory Setting Values...
. 07 NSTALLER SET SYSTEM : Pool solar heating with External heat Exchanger Factory Setting Values Collector Type Cylinder temperature setpoint From R1 Output, R1 pump control, ON/OFF mode (STD) bor speed variation mode (RPM) Temperature difference to switch on the From solar heating Temperature difference to switch off the...
Page 65
. 07 NSTALLER SET Optional function Factory Setting Values Cold start temperature threshold From Expert Setting Factory Setting Values Maximum collector temperature From Collector temperature safety limit From Night temperature setpoint From (for HOLIDAYS mode) Maximum exchanger output From temperature Minimum pump-on duration Expert Setting Plus Factory Setting...
. 07 NSTALLER SET Expert Setting Plus Factory Setting Values Nominal temperature difference for From pump speed control Unit temperature difference for pump From speed control Minimum pump speed ratio From Tube collector temperature test duration From (if TUBE type collector) SYSTEM : Solar system with 2 DHW cylinders (or 2-layer cylinder), 3-way valve and Electric auxiliary heating...
Page 67
. 08 NSTALLER SET Factory Setting Values Storage cylinder loading priority order Storage cylinder loading test period From Temperature difference (from the From temp. setpoint) for Auxiliary heating authorization Language Degree unit Display / light timeout Optional function Factory Setting Values Anti-Legionella function Cooling (safety function)
Page 68
. 08 NSTALLER SET Optional function Factory Setting Values Cold start temperature threshold From Expert Setting Factory Setting Values Maximum collector temperature From Collector temperature safety limit From Night temperature setpoint From (for HOLIDAYS mode) Maximum cylinder temperature (safety) From Minimum pump-on duration Expert Setting Plus Factory Setting...
. 08 NSTALLER SET Expert Setting Plus Factory Setting Values Nominal temperature difference for From pump speed control Unit temperature difference for pump From speed control Minimum pump speed ratio From Tube collector temperature test duration From SYSTEM : Solar system with 2 DHW cylinders (or 2-layer cylinder), Second pump and Electric auxiliary heating Factory Setting Values...
Page 70
. 09 NSTALLER SET Factory Setting Values R3 output Temperature difference (from the From temp. setpoint) for Auxiliary heating authorization Language Degree unit Display / light timeout Optional function Factory Setting Values Anti-Legionella function Cooling (safety function) Maximum cylinder temperature (safety) From Anti-Freeze function Anti-Freeze temperature threshold...
Page 71
. 09 NSTALLER SET Expert Setting Factory Setting Values Maximum collector temperature From Collector temperature safety limit From Night temperature setpoint From (for HOLIDAYS mode) Maximum cylinder temperature (safety) From Minimum pump-on duration Expert Setting Plus Factory Setting Values Length collector probe Temperature difference zero adjustment From value...
. 09 NSTALLER SET Expert Setting Plus Factory Setting Values Unit temperature difference for pump From speed control Minimum pump speed ratio From Tube collector temperature test duration From (if TUBE type collector) SYSTEM : Solar system with Smart Hydraulic auxiliary from Solid Fuel Boiler and Electric auxiliary heating Factory Setting Values...
Page 73
. 10 NSTALLER SET Factory Setting Values Temperature difference to switch off the From Auxiliary heating Heat Source minimum temperature limit From Language Degree unit Display / light timeout Optional function Factory Setting Values Anti-Legionella function Anti-Legionella temperature threshold Cool System (safety function) Maximum cylinder temperature (safety) From Anti-Freeze function...
Page 74
. 10 NSTALLER SET Expert Setting Factory Setting Values Maximum collector temperature From Collector temperature safety limit From Night temperature setpoint From (for HOLIDAYS mode) Maximum cylinder temperature (safety) From Minimum pump-on duration Expert Setting Plus Factory Setting Values Length collector probe Temperature difference zero adjustment From value...
. 10 NSTALLER SET Expert Setting Plus Factory Setting Values Unit temperature difference for pump From speed control Minimum pump speed ratio From Tube collector temperature test duration From (if TUBE type collector) SYSTEM : Solar system with Heating Return Increase Factory Setting Values Collector Type...
Page 76
. 11 NSTALLER SET Factory Setting Values Temperature difference to switch off the From HRI function Language Degree unit Display / light timeout Optional function Factory Setting Values Cool System (safety function) Maximum cylinder temperature (safety) From Anti-Freeze function Anti-Freeze temperature threshold From Cold start function Cold Start temperature threshold...
Page 77
. 11 NSTALLER SET Expert Setting Factory Setting Values Night temperature setpoint From (for HOLIDAYS mode) Maximum cylinder temperature (safety) From Minimum pump-on duration Expert Setting Plus Factory Setting Values Length collector probe Temperature difference zero adjustment From value Additional temperature difference zero From adjustment value T1 temperature zero adjustment value...
. 11 NSTALLER SET Expert Setting Plus Factory Setting Values Minimum pump speed ratio From Tube collector temperature test duration From (if TUBE type collector) SYSTEM F2) and Electric auxiliary heating Factory Setting Values 1 or 2 solar pumps with East/West collector Collector Type Cylinder temperature setpoint...
Page 79
. 12 NSTALLER SET Factory Setting Values Degree unit Display / light timeout Optional function Factory Setting Values Anti-Legionella function Anti-Legionella temperature threshold Cool System (safety function) Maximum cylinder temperature (safety) From Anti-Freeze function Anti-Freeze temperature threshold From Cold start function Cold Start temperature threshold From Expert Setting...
Page 80
. 12 NSTALLER SET Expert Setting Factory Setting Values Maximum cylinder temperature (safety) From Minimum pump-on duration Expert Setting Plus Factory Setting Values Length collector probe Temperature difference zero adjustment From value Additional temperature difference zero From adjustment value T1 temperature zero adjustment value From T2 temperature zero adjustment value From...
. 13 NSTALLER SET SYSTEM : Solar system with 2-layer cylinder, 3-way Valve and Electric auxiliary heating Factory Setting Values Collector Type Cylinder temperature setpoint From R1 output, R1 pump control, ON/OFF mode (STD) bor speed variation mode (RPM) Temperature difference to switch on the From solar heating Temperature difference to switch off the...
Page 82
. 13 NSTALLER SET Optional function Factory Setting Values Anti-Legionella temperature threshold Cool System (safety function) Maximum cylinder temperature (safety) From Anti-Freeze function Anti-Freeze temperature threshold From Cold start function Cold Start temperature threshold From Expert Setting Factory Setting Values Maximum collector temperature From Collector temperature safety limit...
Page 83
. 13 NSTALLER SET Expert Setting Plus Factory Setting Values Length collector probe Temperature difference zero adjustment From value Additional Temperature difference zero From adjustment value T1 temperature zero adjustment value From T2 temperature zero adjustment value From T3 temperature zero adjustment value From Nominal temperature difference for From...
ROUBLESHOOTING Error messages An ERROR (EM) signals a problem that does prevent the system from operating. Display Problem Troubleshooting Short-Circuit at T1 (T2, T3 or T4) T1 (T2, T3, or T4) probe is faulty or preventing the system from working misconnected Open-Circuit at T1 (T2, T3 or T4) T1 (T2, T3, or T4) probe is missing or...
RODUCT RANGE AND ACCESSORIES Codes References STASR001A Solar controller with 3 sensors PT1000 Accessories Codes References STAPT15HTA Sensor for solar controller PT1000, high temperature, 1,5m red cable STAPT25NTA Sensor for solar controller PT1000, normal temperature, 2,5m black cable EGAL GUARANTEE Clause 1 –...
Page 86
ECHNICAL SPECIFICATIONS Inputs / Outputs Description Name 4 temperature inputs PT1000 sensor type T1, T2, T3, T4 1 synchronization input Input driven by a free-voltage contact from a time switch (closed when low-tariff period running) Solar pump control output, rated load Semi-conductor 200W max, mains live switch (0,1A min output current) 2nd control output, rated load...