Wilcoxon iT150 Series Installation And Operating Manual

Wilcoxon iT150 Series Installation And Operating Manual

Vibration transmitters
Table of Contents

Advertisement

Quick Links

Please read this manual thoroughly before making electrical connections and applying
power to the module. Following the instructions in this manual will ensure the
transmitter delivers optimum performance.
Make sure you always use the latest product documentation. The latest manuals and
technical information can be found at www.wilcoxon.com.
Wilcoxon Sensing Technologies
an Amphenol Company
Frederick, MD 21701 USA
Installation and Operating Manual
97038 Rev. A.1
Page 1 of 23
iT150 Series
Vibration Transmitters
Tel: +1 (301) 330-8811
Tel: +1 800 WILCOXON
Fax: +1 (301) 330-8873
www.wilcoxon.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iT150 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Wilcoxon iT150 Series

  • Page 1 Following the instructions in this manual will ensure the transmitter delivers optimum performance. Make sure you always use the latest product documentation. The latest manuals and technical information can be found at www.wilcoxon.com. Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev.
  • Page 2: Table Of Contents

    Cable shielding and earth ground connections ....................14 TBUS ............................14 Power-up ..........................15 Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 2 of 23...
  • Page 3 Figure 12 - RC coupling circuit for non-standard signals ..........................15 Figure 13 - Application example ..................................19 Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 3 of 23 www.wilcoxon.com...
  • Page 4: Introduction

     This document contains information on the installation and Eight frequency band options  operation of the iT150 Series of Vibration Transmitters. The 0.2 - 200 Hz  transmitters are designed and manufactured in the USA by 0.5 - 500 Hz ...
  • Page 5: Abbreviations Used In This Manual

     RoHS Directive, 2011/65/EU in damage to equipment and/or serious personal injury. Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 5 of 23...
  • Page 6: Ordering Information

    Acceleration in, 10mV/g, true peak acceleration out, FS=5 g, 10-25000 Hz iT150-V-500-PP-D-mils-10-0.5-500 Velocity in, 500mV/ips, peak-to-peak displacement out, FS=10 mils, 0.5-500 Hz Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 6 of 23 www.wilcoxon.com...
  • Page 7: Ordering Procedure And Options

    Specify the sensitivity of the sensor. Units are mV/g for Many vibration transmitters develop a peak value for acceleration and mV/ips for velocity. vibration by using this method. The iT150 Series transmitters Sensitivity mV/g have this detection method available to provide comparable results to other vibration transmitters in use.
  • Page 8: Step 4 - Output Type

    2. ips = inches per second 3. mm = millimeters 4. One mil = 0.001 inches Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 8 of 23 www.wilcoxon.com...
  • Page 9: Step 6 - Full Scale

    RMS detectors to settle to their final values. Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 9 of 23 www.wilcoxon.com...
  • Page 10: Basic Circuit Diagram

    It does not protect or isolate against electrical shock. Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 10 of 23 www.wilcoxon.com...
  • Page 11: Io Ports And Signal Assignments

    Power input 18 – P+ Table 1 - Terminal numbers and signal assignments Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 11 of 23...
  • Page 12: Sensor/Transducer Connections

    Connection of a temperature sensor is optional. Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 12 of 23 www.wilcoxon.com...
  • Page 13: 4-20 Ma Current Loop Connections

    The 4-20 mA outputs will not work with externally powered loops. Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 13 of 23 www.wilcoxon.com...
  • Page 14: Cable Shielding And Earth Ground Connections

    WARNING: The iT150 TBUS is NOT compatible with as close as possible to the transmitter. older Wilcoxon iT100/200, iT401 or iT501 series modules. When connecting modules via the TBUS, connect only Wilcoxon provides enclosures with integrated grounding bus iT150/300 series modules together on the same bus.
  • Page 15: Power-Up

    Signal sources not compliant with the BOV requirement can See section 9, “Front panel LEDs” for detailed explanation of use the biasing circuit shown below. If more information is LEDs and unit operating status. required, contact Wilcoxon technical support. Operation 10 – 330 µF iT150 14.1...
  • Page 16: Loop Current Equations

    20.0 mA. When the vibration level is equal to 1 g (100 mV), the loop current will be 7.2 Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873...
  • Page 17: Din Rail Assembly And Removal

    15.2 DIN rail mounting The iT150 Series of modules are designed to mount to a standard 35 mm DIN rail. The rear of the module has a spring-loaded metal foot catch that holds the module securely in place.
  • Page 18: Troubleshooting

    Incorrect transmitter configuration the front-panel BNC connector. Ensure the sensor DC bias is within the acceptable range. Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 18 of 23 www.wilcoxon.com...
  • Page 19: Application Example

    Application example Figure 13 - Application example Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 19 of 23 www.wilcoxon.com...
  • Page 20: Maintenance And Calibration

    Maintenance and calibration The iT150 series transmitters contain no user-serviceable parts. All units are factory-calibrated and require no field adjustment or service. The units have been designed to provide years of continuous, trouble free service under normal operating conditions. Warranty Visit the Wilcoxon web site at www.wilcoxon.com for warranty information.
  • Page 21: Technical Data

    ±1% of full scale Number of FFT lines 1,600 FFT window type Hanning Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 21 of 23 www.wilcoxon.com...
  • Page 22 EN61326-2-3:2006 Electrical equipment for measurement, control and laboratory use - EMC requirements - Particular Requirements - Test configuration NAMUR NE 21 EMC recommendations Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 22 of 23 www.wilcoxon.com...
  • Page 23: Revision History

    Company address changed NOTE: Page numbers for previous revisions may differ from page numbers in the current version. Tel: +1 (301) 330-8811 Wilcoxon Sensing Technologies Tel: +1 800 WILCOXON 97038 Rev. A.1 an Amphenol Company Fax: +1 (301) 330-8873 Frederick, MD 21701 USA Page 23 of 23 www.wilcoxon.com...

Table of Contents