Download Print this page

Munster Simms Engineering Ltd. Whale V-PUMP MK.6 Manual

Advertisement

Quick Links

Read carefully before
installation and use.
To the fitter: Check that
the product is suitable for the
intended application, follow
installation instructions and
ensure operating instructions
are passed onto the end user.
To the User: Read the
following instructions care-
fully.
Application
This product is designed for
use as a domestic freshwater
& saltwater hand pump in
caravans and boats. Use for
any other purpose or with
any other liquid, is not rec-
ommended and is entirely at
the user`s risk.
This pump may also be used
in conjunction with an in-line
pump, or as a back up to a
submersible pump.
Sub mersi bl e
921
V- PUMP MK.6
Installation
Choose an installation where
the pump can be operated
comfortably. Note: The
maximum reach of the outlet
spout is 115mm (4½")
Once you have found your
location, drill a 25mm (1")
hole, fit pump, position base
and secure using the two
wood screws.
Hose connection
If using Whale Water System
15 pipework WX1504 equal
straight will fit directly onto
the pump, if using
System12 use WX1504 &
WS1215 stem reducer 15mm-
12mm alternatively you can
use 13mm (½") flexible
tubing.
The height of the pump
maybe adjusted by loosening
screw (A).
Operation
To operate pump the handle
up and down, water will be
discharged on both strokes.
Maintenance
Regular inspection of valves
and seals is recommended
with cleaning and replace-
ment of components as
necessary.
To dismantle pump:
Unscrew head and spout from
Barrel, pull plunger and head
from barrel. Unscrew plunger
Also Service Kits/Assemblies:
AK0618 & AS0627
cup seat from plunger rod and
pull head and spout from
plunger rod. To remove U-
Packing seal from head,
carefully ease cap (B) off using
a flat screw driver, replace U-
Packing seal making sure to fit
the new seal the same way
round as old seal (U facing
down).
Note: Replacing O-Ring (C)
may prove difficult to remove
and we recommend that it is
not replaced unless a leak is
observed under the head.
Replace cup washer, O-Ring
(D) and buffer on plunger cup
seat.
Reassemble making sure that
cap is securely pushed back
into position
To replace bottom valve (E)
unscrew base from barrel of
pump. A service kit AK0618
is available from dealers.
Contact Whale for MK5 V-
pump drawing or instruction.
NOTE: For winter storage,
ensure that the pump is
drained completely to avoid
frost damage.
GP0650

Advertisement

loading
Need help?

Need help?

Do you have a question about the Whale V-PUMP MK.6 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Munster Simms Engineering Ltd. Whale V-PUMP MK.6

  • Page 1 V- PUMP MK.6 GP0650 Also Service Kits/Assemblies: AK0618 & AS0627 Installation cup seat from plunger rod and Read carefully before Choose an installation where pull head and spout from installation and use. the pump can be operated plunger rod. To remove U- To the fitter: Check that comfortably.
  • Page 2 Whale V Pump Mk6 Note: * contained in Service Kit AK0618 AS0627 Clampling block assembly U Packing* O-Ring*(C) Valve Stem* (E) Valve* AS0628 *(D) O-Ring O-Ring* Plunger cup seat & base Cup packing* assemblies Buffer* Helpful Hints Warranty (a) If the pump is slow to Whale Pumps are guaranteed tion, unauthorised modifica- prime, the cup washer maybe...