  • Page 1 EX SERIES USER EX6K(L) EX10K(L) EX3110K(L) EX3115K(L) EX3120K(L) MANUAL...
  • Page 2 Thank you for using our product. Observe the warnings on the machine and manual strictly and properly keep the manual. Do not operate the UPS before read safety notes and operation instruction.
  • Page 3 Operation safety Read safety notes carefully and thoroughly before operation to ensure on using correctly, and save the manual properly. Pay attention to alarm table on the UPS and operate according to it. Do not install the UPS under the circumstances of direct sunlight, running water, or excessive humidity.
  • Page 4 C. Wear rubber gloves and boots; D. Do not lay tools or metal parts on the battery; E. Disconnect the load before remove the terminal of battery. Do not dispose battery in the fire as they may explode. Prohibit unprofessional people from opening or damaging the battery, It may cause an electrolyte leakage that is toxic and harmful to the skin and eyes.
  • Page 5: Table Of Contents

    Catalog 1. Brief Introduction…………………………………………………………….2 1.1 Description of commonly used symbols……………………………….3 1.2 Front View………………………………………………………………...4 1.3 Back View…………………………………………………………………5 1.4 Product Specification…………………………………………………….6 2. Installation ……………………………………………………………………8 2.1 Unpacking Inspection …………………………………………………..8 2.2 Wiring Table ……………………………………………………………..9 2.3 UPS Connection………………………………………………………..10 2.4 Operation Procedure of External Battery for Long Backup Time UPS ……………………………………………………...
  • Page 6: Brief Introduction

    1. Brief Introduction The Online EX Series is an uninterruptible power supply incorporating double-conversion technology, optional EPO and maintenance switch, parallel redundancy. It provides perfect protection specifically for computer equipment, communication systems and computerized instruments. Its true online double-conversion design eliminates all mains power disturbances.
  • Page 7: Description Of Commonly Used Symbols

    1.1 Description of symbols Meaning Symbols Meaning Notice or Fault High voltage risk Earth protection Circle Do not place with sundries Overload Battery inspection Power on/off UPS...
  • Page 8: Front View

    1.2 Front View EX6K/EX10K/EX3110KL EX6KL/EX10KL EX3115KL/EX3120KL 1.3 Rear View EX6K EX10K...
  • Page 9: Back View

    EX6KL EX10KL EX3110KL EX3115KL/EX3120KL...
  • Page 10: Product Specification

    ① Computer Interface ② Intelligent Slot ③ Fan ④ Parallel Card Plate (selectable accessory) ⑤ Input Protective Breaker ⑥ Maintenance Switch cover plate (Maintenance bypass switch is just available for professional rev) ⑦ Terminal Blocks Cover ⑧ Self-locking frame ⑨ EPO (Just available for professional rev) Remarks: About the model with parallel card and maintenance switch please remove the cover of ④...
  • Page 11 Frequenc 46Hz~54Hz y Range Power 0.99 0.95 Factor Output Voltage 220VAC×(1±1%) Current Frequenc 46Hz~54Hz (Line Mode. Same as input frequency), 50Hz×(1±0.1%)(Battery Mode) Power Factor Overload 105%~125%,1 minutes minimum, then transfer to bypass and alarm, Bypass over Capability load > 30 minutes then turn off output;...
  • Page 12: Installation

    Storage -25℃~55℃ Temperature 20%~90% (Non condensing) Humidity Altitude <1000m High altitude area load=rated power × derating coefficient (corresponding to altitude) 1000 1500 2000 2500 3000 3500 4000 4500 5000 Altitude(m) 100% Derating coefficient Note: if the UPS is installed or used in the place where the altitude is above than 1000m, the output power must be derated in using, please refer to the above table.
  • Page 13: Wiring Table

    Recycle: The packing material is recycled, please reserve packing material for using in the future. 2.2 Wiring Table Note:The diameter of connection wire depend on rated power of In the below table, for single phase model, “L” represents line wire, for three phase model, “L”...
  • Page 14 current please refer to 1.4) Select proper wire according to wiring table Open the terminal block cover① on the back panel of UPS Connect the input and output wires to the corresponding input and output terminal, if need connect batteries then connect the battery cables to the battery input terminal.
  • Page 15 Single phase model terminal block: EX6K/EX10K (BAT Input terminal is useless) EX6KL/EX10KL Three phase model terminal block: EX3110KL/EX3115KL/EX3120KL Install the terminal block on back panel and screw tighten it. After connecting wires, turn on main power, and then turn on UPS input protective breaker and UPS.
  • Page 16: Operation Procedure Of External Battery For Long Backup Time Ups

    2.4 Operation Procedure of External Battery for Long Backup Time UPS The nominal DC voltage of external battery pack is 192VDC. Each battery pack consists of 16 pieces of 12V maintenance free batteries in series. To achieve longer backup time, it is possible to connect multi-battery packs, but the principle of “same voltage, same type”...
  • Page 17: Connect To Computer Interface

    hazardous of electric shock. 3. To complete the connection by connecting the external battery cable with corresponding terminal on terminal block of the UPS. Do not attempt to connect any load to the UPS now. You should connect the input power wire to the right position first.
  • Page 18: Parallel Card (Optional Accessory)

    2.6 Parallel Card (Optional Accessory) 1. Brief introduction of the redundancy N+X is currently the most reliable power supply structure. N represents the minimum UPS number that the total load needs; X represents the redundant UPS number. The bigger the X is, the higher reliability of the power system is.
  • Page 19 Connect the output wires of each UPS to an output breaker panel, and then connect from output breaker panel to load. Note: The requirement of the output wiring is as following: When the distance between the UPSs in parallel and the breaker panel is less than 20 meters, the difference between the wires of input &...
  • Page 22: Installation Of Intelligent Card

    3. Merit representation of UPS in parallel It can improve the reliability of power system through redundant structure. Two UPS in same capacity afford same load, when one UPS is fault another UPS can afford the load alone. It is so called 1/2 redundant, fault UPS can be repaired respectively, every UPS of professional rev has maintenance bypass switch built-in.
  • Page 23 2. Insert intelligent card into intelligent slot. 3. Install intelligent card with screw. SNMP Card (Optional Accessory) Intelligent card is located at intelligent slot of back panel of UPS provide data allowed by SNMP. AS400 Card (Optional Accessory) Installing AS400 card in intelligent slot can achieve monitor function through AS400 system, pin introduction of AS400 card used as power supply monitor management show as below: meaning...
  • Page 24: Epo

    2.8 EPO (Optional Accessory) EPO (Emergent Power Off), EPO appears in green terminal located at back panel of UPS, user can shut down UPS through EPO in emergency. There are two connection methods showing as below: ①、 UPS power off urgently when pin1 and pin2 are on Short pin1 and pin2, UPS power off urgently when pin3 and pin4 are off 2.9 Maintenance Switch (Optional Accessory) User can maintain UPS through maintaining switch, the diagram shows as...
  • Page 26: Dust-Proof (Optional Accessory)

    2.10 Dust-proof (Optional Accessory) Dust-proof can prevent dust from entering into UPS, it is necessary to use dust-proof in the area with high dust and smog. Dust-proof is installed inside of front panel. About installation procedure, please refer to installation manual of dust-proof. 1.
  • Page 27: Button Description

    Function Power on/off Confirm Select Press same time can set mode and data 3.2 Button Description Button Name Function Press it and hold over 2s, UPS will start. And press it and Power on/off hold over 3s again, UPS will shut down. Press it 1s, UPS will work in mute mode.
  • Page 28: Panel Display & Meaning

    3.3 Panel Display & Meaning Display Sign Meaning When UPS failure this signal will display, and together with the corresponding code. 00 Standby mode; 01 AC mode; 02 Battery Inverter mode; 03 Battery test mode; 04 Power saving mode; 05 Bypass mode. Battery mode mute display, when mute mode, will show “X”.
  • Page 29: Fault Code & Meaning

    Display load capacity, When VA value>W value, show VA value, and when W value>VA value, show W value. Means Overload. When overload, it will alarm and flash every second. Display Load. Means battery is being charged. Means battery voltage is low, when alarm it will flash every second.
  • Page 30 Overload Fault, (Fault sign T6 light, UPS load is bigger than UPS rated Alarm beeps continually, “OVER LOAD” power, after decrease load light, right negative frame flash every equipments quantity, UPS will work 1s). normally. If still can not solve, please contact with manufacturer or dealer.
  • Page 31: Operation

    AC input fuse open circuit fault, (Fault Confirm if AC cable connect well, If sign T6 light, Alarm beeps continually) still can not solve, please contact with manufacturer or dealer. EEPROM data loss, (Fault sign T6 light, Please contact with manufacturer Alarm beeps continually) or dealer.
  • Page 32 bypass mode. UPS start to self-test after pressing UPS “Power ON” Button over 2s, the screen appear self-test sign, and then disappear. After self-test, UPS start. 2. Start UPS connecting with DC power without AC main power: 1) Without AC Main Power connected, turn on UPS by pressing “Power ON”...
  • Page 33: Operate Mode

    4.2 Operate mode 1. AC mode AC Mode 2. Battery Mode Battery Mode...
  • Page 34 3. Standby Mode Standby Mode 4. Bypass Mode Bypass Mode...
  • Page 35: Battery Maintenance

    5. Battery Maintenance The battery is key component of the UPS. The battery lifetime depends on the circumstance temperature, charge and discharge times. High circumstance temperature and deep discharge will shorten the battery lifetime. 1) Sealed maintenance-free lead –acid battery be used in the standard. When being connected to the utility power whether the UPS has been turned on or not, the UPS keeps charging the battery and also offers the protective function of over charging and over discharging.
  • Page 36: Warranty

    6. Warranty We offer its product free warranty service for three years from the date of purchasing (Batteries below 12v24ah enjoy 1year warranty): u To obtain service under warranty via an valid guarantee offered by dealers; u To obtain service under warranty via serial number. In case of UPS fault, please contact the nearest service center and dealer.