Etatron America WATER METER SIGNAL SPLITTER Operating Instructions And Maintenance

Receives a reed input signal from a water meter counter and divides it into four equal and synchronous reed output signals.

Advertisement

Quick Links

Water Meter Signal Splitter
OPERATING INSTRUCTIONS AND MAINTENANCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WATER METER SIGNAL SPLITTER and is the answer not in the manual?

Questions and answers

Summary of Contents for Etatron America WATER METER SIGNAL SPLITTER

  • Page 1 Water Meter Signal Splitter OPERATING INSTRUCTIONS AND MAINTENANCE...
  • Page 3: Table Of Contents

    W arranty ............................5 WATER METER SIGNAL SPLITTER eMP ..........................6 Operati ng pri nci pl e .
  • Page 4: Safety Standards

    SAFETY STANDARDS Symbols used in the manua l WARNING PROHIBITED INFORMATION NOTICE Precedes a text that is very important Precedes information that is for the protection of the health of Precedes information concerning inherent to safety. It flags exposed persons or for the machine the use of the equipment.
  • Page 5: Shipp Ing To The Factory For Repairs And /Or Ma Intenance

    3mm between its contacts. Please pay particular attention to this last point and we recommend the user to consult the enclosed drawings and chapter “RISKS” before starting any operations. Warranty 2 years. For warranty contact ETATRON AMERICA. ENGLISH 5...
  • Page 6: Water Meter Signal Splitter Emp

    Classification with respect to protection against indirect contacts: CLASS I (the equipment is supplied with an electrical protection conductor). • Galvanically isolated outputs Reference Standards The water meter signal splitter is in accordance with the following directives: • 2006/95/CE: "low tension" •...
  • Page 7: Installation

    INSTALLATION Introduction This section describes steps for installing the equipment and wiring. Please read this instruction before starting any activity. Follow these guidelines when installing the equipment: • Make sure the equipment is powered off and any other related equipment before starting any activity. •...
  • Page 8: El Ectri Cal Connecti Ons

    Electrica l c onnection s The following figure describes the electrical connections. Fig. 2 – Wiring If you open the front cover pay attention to the insulation of the cable terminals. If necessary restore it to avoid short cuts. ENGLISH...
  • Page 9: Operating Instructions

    OPERATING INSTRUCTIONS Front Pane l Fig.4 - Front panel Power ON Led (green) and operational LED (flashing red) Yellow flashing LED, output pulse to CONTROLLER Yellow flashing LED, output pulse to PUMP 1 Yellow flashing LED, output pulse to PUMP 2 Yellow flashing LED, output pulse to PUMP 3 LED de scription LED 1 light up green when the equipment is power on...
  • Page 10: Maintenance

    MAINTENANCE Ordinary An Ordinary and accurate maintenance with a programmed check, guarantee the preservation over time and the proper functioning of the systems. Therefore, we recommend that the user follow our advice and maintenance of a service contract and assistance programmed with one of our Technical Support Centre. Check at least every 6 months functioning of the equipment.
  • Page 12 ETATRON AMERICA Dilution Solutions Inc 2090 Sunnydale Blvd Clearwater FL 33765 Telephone: 727-451-1198 FAX: 727-451-1197 WDMU00216ML1A (08 - 2017)