jablotron UC-280 Instructions page 2

Wireless interface

Advertisement

Enrolling of wireless components
Enrolling of detectors
• Scroll to a desired zone Z1-Z8 using the LEARN button
• JA-60 detectors will be enrolled by inserting their batteries or switching
on a power supply
• Successful learning is indicated by the red LED
• If you enroll a component to a new zone, it will move from its previous
position
• Only one detector can be enrolled to each zone
Enrolling of remote controls
• Scroll to a desired zone Z1-Z8 using the LEARN button
• RC-xx remote controls will be enrolled by pressing a button (while in
pulse mode). Button A, B or double press can be enrolled.
• RC-11 or RC-86 Remote controls can be enrolled to any zone in an
ON/OFF mode by pressing both buttons and keeping them pressed for
more then 5 sec. After this the corresponding relay will switch on when
the A button is pressed, and off, when the B button is pressed.
• If a combination of double press and ON/OFF mode is required, the
ON/OFF mode must be enrolled first.
• Successful learning is indicated by the red LED
• If you enroll a remote control to a new zone, it will move from its
previous position
• Only one remote control can be enrolled to each zone
Enrolling of a wireless siren
• Connect a battery in a JA-63A siren and power its adapter
• Select the SIR position with the LEARN button
• When the SIR position is selected, the UC-280 will send a learning
signal to the JA-63A and vice versa. Triggering the SIR input will then
activate a JA-63A, tamper alarm or power supply failure of the JA-60A
will be transmitted to a UC-280
• Only one JA-63A siren can be used with a UC-280
Enrolling of UC-216 or UC-222 modules
• Select the learning mode in a receiver (mode X1 for UC-216 or mode
4 for UC-222)
• Learning mode of UC-280 must be closed
• Press and hold the LEARN button in UC-280 for 3 seconds
• The UC-280 will now be enrolled to the UC-216 or UC-222 receivers
and triggering of X and Y inputs will trigger the UC-216 / UC-222
output relays.
• Unlimited number of UC-216 / UC-222 can be used with a UC-280
Erasing components
If you want to delete any item from a UC-280, use the RESET button (the
procedure is described in "Setting buttons" paragraph).
UC-280 wireless interface
Specification
Power
Power consumption
Zone outputs Z1-Z8
Outputs
Tamper
Fault, Battery
Operating frequency
Working range with JA-60
Working range with RC
Working environment
Operating temperatures
Operating humidity
Dimensions
Weight
Complies with
ETSI EN 300220, EN 50130-4, EN 55022, and EN 60950-1
Can be operated according to
Includes: board, tape antenna, mounting posts, instructions
JABLOTRON ALARMS hereby declares that the UC-280 is in
compliance with the essential requirements of 1999/5/EC
directive. The original of the conformity assessment can be
found at www.jablotron.com, Technical Support section
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
producer after use.
2 / 2
12 V DC (10.5 V – 16.0 V)
typ. 50 mA (all relays off)
max. 100 mA
8x opto-MOS relays 100 mA / 60 V
with COM1 common terminal
3x opto-MOS relays 100 mA / 60 V
NC with COM2 common terminal
NO with COM2 common terminal
X, Y and Siren inputs activated
when switched to GND (filter 0.2
sec., 1 V DC triggering level)
433.9 MHz
100 m (open area)
30 m (open area)
indoor use (class II, EN 50131-1)
-10 ° C to +40 ° C
max. 90 %
142 x 74 mm
ERC REC 70-03
MFT51209
250 g