GHM-Martens TS125 Operating Manual

Switch amplifier

Advertisement

Quick Links

English
Operating manual
Switch amplifier
TS125 / TS225
Companies / brands of GHM
www.ghm-messtechnik.de
Save for later reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TS125 and is the answer not in the manual?

Questions and answers

Summary of Contents for GHM-Martens TS125

  • Page 1 English Operating manual Switch amplifier TS125 / TS225 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference.
  • Page 2: Table Of Contents

    Assembly and installation ....................9 3.1. Mechanical assembly ..................9 3.2. Electrical installation ..................9 Controls and functional description ................10 4.1. TS125...-1, TS125...-2, TS225...-1 TS225...-2: ..........10 Commissioning, maintenance and service ..............14 5.1. Commissioning ....................14 5.2. Maintenance ....................14 5.3.
  • Page 3: Intended Use (Areas Of Application)

    GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de Intended use (areas of application) Refer to the chapter 'Product description' for detailed specifications for the area of application. The operational safety of the device is only assured when used as intended in accordance with the specifications in the operating manual.
  • Page 4: Safety Signs And Symbols

    GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de Any processes described in this operating manual may only be carried out by trained, qualified personnel who are authorised by the owner and wearing protective clothing.
  • Page 5: Standards And Directives

    Testing standards EN61508-1: 2010 (Issue years for testing standards belong to german versions) Product description Switch amplifiers of the series TS125 and TS255 are used in switch cabinets for the conversion and isolation of digital switching signals, optionally also in explosive areas.
  • Page 6: Scope Of Delivery

    Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de 2.1. Scope of delivery  TS125 or TS225  this operating manual 2.2. Functional principle The output relay and the diodes are controlled at the device front depending on the status of the measuring inputs.
  • Page 7: Connection Diagram

    GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de 2.3. Connection diagram 2.4. Type plate The type plate includes the most important identification data  Type and article name ...
  • Page 8: Carrier Rail Bus - Powerrail

    GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de 2.5. Carrier rail bus - PowerRail The power supply voltage supply of multiple devices can be concentrated in the mounting carrier rail (TS35 ) of a bus system.
  • Page 9: Assembly And Installation

    Terminals 41, 42 (Channel 1) and 51, 52 (Channel 2) are intended for the sensors and/or input switches. With TS125 the normally open relay outputs are at Terminals 31, 32 (Channel 1) and/or 21, 22 (Channel 2) With TS225 the changeover relay outputs are at Terminals 31-33 (Channel 1)
  • Page 10: Controls And Functional Description

    Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de Controls and functional description 4.1. TS125...-1, TS125...-2, TS225...-1 TS225...-2: 1 or 2 channel switch amplifier - Green operating display Operating elements per channel Ch.1 / Ch.2 - LEDs A1/A2...
  • Page 11 GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de Ch.1 and Ch.2 switching behaviour Input Switch INV Switch ERR Relay open closed open (<0.2mA) open on or off on or off open inactive (0.4…1.2mA)
  • Page 12 Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de TS125...-F, TS225...-F 1-channel isolating amplifier with additional error relay or parallel relay. Also enables simulation of a changeover contact in the narrow housing. Operating elements...
  • Page 13 GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de Switching behaviour TS125...-F, TS225...-F (with error relay) Input Ch.1 switches Relay A1 and A2 Standard relay A1 Switch INV-...
  • Page 14: Commissioning, Maintenance And Service

    GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de Commissioning, maintenance and service 5.1. Commissioning 1. Ensure that the connection assignment takes place according to the connection diagram and matches the power supply. 2.
  • Page 15: Technical Data

    GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de Technical data Explosion protection Device versions with intrinsicallsafe inputs for Zone 0/1 (TS125L-Ex.., TS125LP-Ex.., TS125M-Ex.., TS225M-Ex..) II (1) G [Ex ia Ga] IIC/IIB Dust II (1) D [Ex ia Da] IIIC 1) BVS 14 ATEX E079 certificate...
  • Page 16 <125V DC <0.2A <25W < 30V DC <2A <60W Switching frequency max. 5Hz -delay max. 30ms Casing Dimensions (WxDxH) TS125: 12.5 x 114 x 108mm TS225: 22.5 x 114 x 108mm Material PA6.6, light grey Weight TS125: 120g TS225: 140g Protection type...
  • Page 17: Mechanical Design / Dimensions

    GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de Functional safety SIL2 (parameters in accordance with EN61508 and SN29500) Device type Response time Standard Mode -> Error Mode 30ms Error Mode ->...
  • Page 18: Order Code

    GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de Order code 1. Device version 125L Housing width 12.5 mm, normally open relay contacts, Supply voltage 24V DC +/- 15% 125LP Housing width 12.5 mm, normally open relay contacts, Supply voltage 24V DC +/-15% with carrier bus rail connection *)
  • Page 19: Returns

    GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de Returns The legal regulations for environmental protection and our personnel require that devices which are sent back which have come into contact with liquid are handled without risk to people or the DANGER environment.
  • Page 20: Eu Declaration Of Conformity

    GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de EU Declaration of Conformity...
  • Page 21 GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de...
  • Page 22 GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de...
  • Page 23 GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de...
  • Page 24 GHM Messtechnik GmbH – Martens Kiebitzhörn 18 ● 22885 Barsbüttel ● Germany Phone +49-40-670 73-0 ● Fax -288 www.ghm-messtechnik.de ● info@martens-elektronik.de V1.09...

This manual is also suitable for:

Ts225

Table of Contents