Download Print this page
Caho DTS961 Instruction Manual

Caho DTS961 Instruction Manual

Digital controller with timer + steam

Advertisement

Quick Links

CAH0
PANEL DESCRIPTION
 
ON
Steam
Timer
CAHO
Digital Temperature Controller with Timer
ON
OFF
PARAMETER DESCRIPTION LIST AND SETTING:
A. FOR TEMPERATURE CONTROL PARAMETER
(PRESS AND HOLD ON/OFF BUTTON FOR 5 SECS TO ENTER EACH PARAMETER LEVEL)
CODE
DESCRIPTION
A1
ALARM1 SET VALUE
A2
ALARM2 SET VALUE
P
PROPORTIONAL BAND
Ct
CYCLE TIME
Hys
HYSTERESIS
PVO
PV OFFSET
SV OFFSET
SPO
ON
ON/OFF SETTING MODE
TON
TIME-ON SELECTION
TeD
TIME-END SELECTION
DB
-
INPUT SELECTION TYPE
TYP
LOL
LOWEST TEMP. SETTING LIMIT
H L I
HIGHEST TEMP. SETTING LIMIT
FILTER SETTING
f I l
CONTROL ACTION SETTING
Act
SV LOOP DISPLAY SETTING
Td1
ALARM DELAY TIME SETTING
Td2
ALARM1 MODE SETTING
A1F
A2F
ALARM2 MODE SETTING
ALARM1 HYSTERESIS SETTING
A1Y
A2Y
ALARM2 HYSTERESIS SETTING
CH
4-20mA OUTPUT HIGHEST SETTING
CL
4-20mA OUTPUT LOWEST SETTING
VER
VERSION
DIGITAL CONTROLLER WITH TIMER+STEAM INSTRUCTION MANUAL
1 0
UP / DOWN KEY
DTS961
DEFAULT
SETTING RANGE UNIT
VALUE
LOL~HIL
LOL~HIL
0~100
%
0~100
RELAY = 10 SEC
SEC.
SSR = 2 SEC
SCR = 0 SEC
0~50%FS
- 99~50%FS
- 99~50%FS
1、2、3
、4、5
1~300
OFF
OFF
OFF
、 on
OFF
-50~50
type
K . J
0~SV
SV~400
400
0~100
H/C
0、5、10、30
、60
SEC.
0~100
SEC.
No、hi、lo、dFh、dFl
No、hi、lo、dFh、dFl
0~A1
0~A2
0~500
470
0~500
ON / OFF BUTTON KEY: Power on/off button key. It is also used to
enter each parameter level for setting.
OFF BUTTON KEY: Is used to stop/halt output. Screen display "OFF",
ON / OFF
flashing together with the current temperature value alternately.
ON BUTTON KEY: Output ON. Display SV temperature (flashing)
first, then in a few seconds it will display the current temperature after.
TEMPERATURE
KEY SETTING
UP KEY: Is used to increment set value.
DOWN KEY: Is used to decrement set value.
TIMER KEY
SETTING
Use to run and stop
TIMER
timer after setting.
BUTTON KEY
LED ON: OUTPUT ON
OUTPUT
LED OFF: OUTPUT OFF
INDICATOR
Whether the power had directly applied or by pressing the ON/OFF power button, the
screen will display the set temperature value (flashing) first, then to be followed by the
current temperature value.
Regardless of what parameter level you are in, if left idle within 5 secs, the display
will automatically return to its original operation mode.
REMARKS
10
A 1F
IF SET NO, NO DISPLAY
20
A2F
IF SET NO, NO DISPLAY
BECOMES ON/OFF CONTROL
0
IF P=0
PARAMETER NOT AVAILABLE IF P=0
2
AVAILABLE IF P=0
0
0
REFER TO NOTE (1) -
1
ON/OFF MODE SETTING DESC.
REFER TO NOTE (2) -
SETTING TON VALUE
IF
TeD
= on, OUTPUT
TURNS OFF AUTOMATICALLY.
0
SETTING NOT AVAILABLE
K
0
2
H
H:
C:
HEATING
COOLING
0
0
REFER TO NOTE (3) -
NO
ALARM OUTPUT TYPES
REFER TO NOTE (3) -
NO
ALARM OUTPUT TYPES
1
1
CT=0
ONLY APPEARS WHEN
90
CT=0
ONLY APPEARS WHEN
- 1 -
STEAM
BUTTON KEY
B. EXPLANATORY NOTE:
NOTE (1): ON/OFF MODE SETTING DESCRIPTION:
CODE
MODE DESCRIPTION
OUTPUT STOP, ALARM OFF
OUTPUT STOP, ALARM ON
OUTPUT STOP, ALARM OFF
POWER ON:
4
OUTPUT STOP, ALARM OFF
POWER ON:
5
OUTPUT STOP, ALARM OFF
NOTE (2): Setting the value range for
It refers to the difference between the display temperature
value and the setpoint value.
For instance:
SV = 100
TON = 1
It indicates that once the temperature reaches 99 degrees
celcius, the controller timer will start automatically.
NOTE (3): ALARM OUTPUT TYPES ILLUSTRATION:
(A1F AS EXAMPLE)
CODE
DESCRIPTION TYPE
No
NO ALARM
ABSOLUTE VALUE
hi
UPPER LIMIT
ABSOLUTE VALUE
lo
LOWER LIMIT
DEVIATION
DFH
UPPER LIMIT
DEVIATION
DFL
LOWER LIMIT
Use to activate and
deactivate steam.
SCREEN DISPLAY
"OFF"
"OFF"
ALL OFF
NO DISPLAY
SCREEN DISPLAYS
"OFF" WHEN
POWER ON
DECIMAL POINT
LIT ON
TON
ILLUSTRATION
NONE
A1
A1 ON
A1
A1 ON
A1
A1 ON
SR-D961
SV
A1
A1 ON
SV
2017 NO. 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the DTS961 and is the answer not in the manual?

Questions and answers

Summary of Contents for Caho DTS961

  • Page 1 * screen will display the set temperature value (flashing) first, then to be followed by the current temperature value. DTS961 Regardless of what parameter level you are in, if left idle within 5 secs, the display * will automatically return to its original operation mode.
  • Page 2 OUTPUT CONTACT RL2 STEAM FUNCTION SPECIAL CHARACTER GUIDE DIMENSION PANEL CUT-OUT 91*91mm (Unit: mm) MODEL 96 96 12 92 90 91 91 120 110 +0.5 +0.5 DTS961   CAHO Digital Temperature Controller with Timer DTS961 WIRING DIAGRAM ORDERING CODE 附加功能 Option 計時+蒸氣...