Salutron HardyTest D700 User Manual

Portable hardness tester
Table of Contents

Advertisement

Quick Links

Portable Hardness Tester
H
a
r
d
y
T
e
s
t
D
7
0
0
®
H
a
r
d
y
T
e
s
t
D
7
0
0
®
User's Manual

Advertisement

Table of Contents
loading

Summary of Contents for Salutron HardyTest D700

  • Page 1 Portable Hardness Tester ® ® User’s Manual...
  • Page 3: Table Of Contents

    User´s Manual HardyTest D700 ® Content 1 OVERVIEW............................5 1.1 A ..........................5 DVANTAGES 1.2 M &T ................... 5 PPLICATION ESTING ANGE 1.2.1 Main Application ........................5 1.2.2 Testing Range ........................5 1.3 C ..........................6 ONFIGURATION 1.4 W ........................6...
  • Page 4 User´s Manual HardyTest D700 ® 6.5.2 Average Times Setting ...................... 16 6.5.3 Material Setting ........................16 6.5.4 Hardness Scale Setting ....................17 6.5.5 Tolerance Limit Setting ..................... 17 6.5.6 Hardness/бb Setting ......................17 6.6 P ........................... 18 RINT UNCTION 6.6.1 Print Current ........................18 6.6.2 Print Memory ........................
  • Page 5: Overview

    User´s Manual HardyTest D700 ® 1 Overview 1.1 Advantages Wide measuring range. Based on the principle of Leeb hardness testing theory. It ♦ can measure the Leeb hardness of all metallic materials. Large screen (128×64 dot matrix LCD), showing all functions and parameters.
  • Page 6: Configuration

    User´s Manual HardyTest D700 ® Configuration Table 1-1 Item Quantity Remarks Standard Main Unit Configuration D type impact device With cable Standard test block Cleaning brush (I) Small support ring Battery Charger 9V 500mA Paper for printing Manual Instrument case...
  • Page 7: Structure Feature &Testing Principle

    User´s Manual HardyTest D700 ® 2 Structure Feature &Testing Principle 2.1 Structure Feature 2.1.1 The Hardness Tester Appearance SaluTron 1. Main unit 2. Impact device SAVE FEED MENU ENTER 2.1.2 Parts of the Main body HL0108070811 SaluTron Portable Hardness Tester...
  • Page 8: D Type Impact Device

    User´s Manual HardyTest D700 ® 2.1.3 D Type Impact Device 1 Release button 2 Loading tube 3 Guide tube 4 Coil unit 5 Connection cable 6 Impact body 7 Support ring 2.1.4 Different Types of Impact Device D+15 2.2 Leeb Hardness Testing Principle...
  • Page 9: Technical Specifications

    User´s Manual HardyTest D700 ® 3 Technical Specifications Error and repeatability of displayed value see Table 3-1.  Table 3-1 Type of impact Hardness value of Leeb Error of displayed Repeatability device standard hardness block value 760±30HLD ±6 HLD 6 HLD 530±40HLD...
  • Page 10: Preparation & Testing

    User´s Manual HardyTest D700 ® 4 Preparation & Testing 4.1 Preparation & Inspection before Testing 4.1.1 Preparation of Sample Surface Preparation for sample surface should conform to the relative requirement in the Appendix Table 3. In the preparation processing for sample surface, the hardness effect of being ♦...
  • Page 11: Testing Program

    User´s Manual HardyTest D700 ® 4.2 Testing Program Verification of the tester is by using standard test block. The error and repeatability of displayed value should be within the regulation of Appendix table 2. Note : Use a calibrated hardness tester, test the standard test block downward vertically for 5 times, the arithmetical average value compare with the value of standard test block.
  • Page 12: Read Measured Value

    User´s Manual HardyTest D700 ® three indentations which need conversion hardness, using Leeb hardness arithmetic average value and corresponding hardness average value as correlative value respectively, make individual hardness contrastive curve. Contrastive curve at least should include three group of correlative data.
  • Page 13: Operation In Details

    User´s Manual HardyTest D700 ® 6 Operation in Details 6.1 Power On Press [ ] to power on the system. The screen shows as below: D700 HARDNESS TESTER Probe Type:D The system would automatically detect the type of the impact device during power up, and would display this information on the screen.
  • Page 14: Testing Operation At The Main Display Interface

    User´s Manual HardyTest D700 ® the presetting impact times. Hardness scale Hardness method of the present measured value. : Display present single time measured value ( without mean value indicator) , Measured value : or display the present mean value (with average value indicator prompting).
  • Page 15: Test Set

    User´s Manual HardyTest D700 ® Impact Direc. Test Set Average Material Print Current Print Set Print Memory Print All Mem View From No.1 View From End The Main Display Interface View From No. Memory Manager Transfer Delete by No. Delete All Auto Save:...
  • Page 16: Average Times Setting

    User´s Manual HardyTest D700 ® Press key [ESC] to cancel it. 6.5.2 Average Times Setting Press [] or [] to move the cursor. Mean Times Press [] or [] to change the number. ------------- Press key [ENTER ]to confirm it. Press key [ESC ]to cancel it.
  • Page 17: Hardness Scale Setting

    User´s Manual HardyTest D700 ® Mild Steel Press key [] or [] to move the cursor to the material to want to preset. High-C Steel Press key [ENTER ]to confirm it. Cr Steel Press key [ESC ]to cancel it. Cr-V Steel 6.5.4 Hardness Scale Setting...
  • Page 18: Print Function

    User´s Manual HardyTest D700 ® 6.6 Print Function At the main display interface, press [MENU ] to enter the main menu. [] or [] to move the cursor to print menu and press [ENTER ]to enter the print menu. Note: ♦...
  • Page 19: View From No.1 Group/View From Ending Group

    User´s Manual HardyTest D700 ® Press key [] or [] to move the cursor View From No.1 to the function wanted, then press key View From End [ENTER ]to confirm. View From No. Transfer Delete By No. Delete All 6.7.1 View from No.1 Group/View from Ending Group [ View from No.1...
  • Page 20: Delete All Data

    User´s Manual HardyTest D700 ® 6.7.5 Delete All Data [Delete All ]will delete all the data in the memory. 6.7.6 Deletion Confirmation Press [] or [] to move the cursor to --------------- [YES ] and press key [ENTER Confirm delete?...
  • Page 21: System Set

    User´s Manual HardyTest D700 ® ↑ 6.9 System Set At the main display interface, press key [MENU ] enter the main menu. Press key [] or [] to move the cursor Test Set to [System Set ]Menu. Press key [ENTER...
  • Page 22: Lcd Brightness Set

    User´s Manual HardyTest D700 ® 6.9.1 LCD Brightness Set Press key [] to enhance the brightness. LCD brightness Press key [] to weaken the brightness. --------------- Press key [ENTER ]to confirm the modifying. Press key [ESC ]to cancel Bright:Press[ ] the modifying.
  • Page 23: El Background Light

    User´s Manual HardyTest D700 ® Calibration Set the impact direction as -------------- Measure points standard 0/5 times hardness block. It would display the average value after Calibration measuring 5 times. -------------- Press key figure [] or [] to input the nominal value.
  • Page 24: Battery Charge

    User´s Manual HardyTest D700 ® 6.15 Battery Charge The instrument uses a NI-MH battery pack as its power source. When the battery pack almost runs out, the battery symbol on the display will glint . It needs charging as soon as possible. Try to drain your battery pack as fully as possible before it is charged for longest battery service.
  • Page 25: Servicing & Maintenance

    User´s Manual HardyTest D700 ® 8 Servicing & Maintenance 8.1 Impact Device Servicing After the impact device has been used for 1000--2000 times, please use the nylon brush provided to clean the guide tube and impact body. When cleaning the guide tube, unscrew the...
  • Page 26: Appendix

    User´s Manual HardyTest D700 ® APPENDIX Table 1 Hardness Values Materials Impact device Hard- Material ness D/DC D+15 scale 20-68.5 19.3-67.9 20.0-69.5 22.4-70.7 20.6-68.2 38.4-99.6 47.7-99.9 37.0-99.9 Steel and 59.1-85.8 61.7-88.0 cast steel 127-651 80-638 80-683 90-646 83-663 81-646 83-976...
  • Page 27: Material

    User´s Manual HardyTest D700 ® Table 2 Material Strength Material Strength σ (MPa) Mild steel 350~522 374~780 High-Carbon steel 500~710 737~1670 Cr steel 500~730 707~1829 Cr-V steel 500~750 704~1980 Cr-Ni steel 500~750 763~2007 Cr-Mo steel 500~738 721~1875 Cr-Ni-Mo steel 540~738 844~1933...
  • Page 28: D Etails I Mpact D Evices

    User´s Manual HardyTest D700 ® Table 3 Technical Details Impact Devices Type of impact device D, DC, DL D+15 Impacting energy: 11mJ 11mJ 2.7mJ 90mJ 11mJ Mass of impact body: 5.5g/7.2g 7.8g 3.0g 20.0g 5.5g Test tip hardness: 1600HV 1600HV...
  • Page 29: Supporting

    User´s Manual HardyTest D700 ® Table 4 Supporting Rings Type Sketch of non-conventional Remarks Supporting ring For testing cylindrical outside Z10-15 surface R10~R15 For testing cylindrical outside Z14.5-30 surface R14.5~R30 For testing cylindrical outside Z25-50 surface R25~R50 For testing cylindrical inside surface HZ11-13 R11~R13...
  • Page 30: Specifications

    User´s Manual HardyTest D700 ® Table 5 Specifications Specifications HardyTest D700® Specifications are subject to change without prior notice. Hardness units: HL (Leeb), HB (Brinell), HRB (Rockwell B), HRC (Rockwell C), HV (Vickers), HS (Shore D) Measuring range: 170 – 960 HLD Measuring direction: 360°...
  • Page 32 SaluTron Messtechnik GmbH Dr.-Gottfried-Cremer-Allee 30/7 · D-50226 Frechen Tel. +49 (0) 2234 9999960 · Fax. +49 (0) 2234 9999962 Email: info@salutron.de · www.salutron.de...

Table of Contents